Biochemical Filter
Wendi’s biochemical filters are widely used in biochemical analyzers, microplate readers and similar analytical instruments, where optical performance determines testing precision and sensitivity. Ion-source-assisted deposition has enabled more than 20 wavelengths and over 100 common specifications. High blocking optical density, steep blocking edges and broad blocking ranges ensure excellent absorbance-measurement precision. Multichannel beamsplitting filters enable simultaneous multiparameter analysis, giving each wavelength-specific detector approximately equal energy input. These filters combine narrowband filters with dichroic mirrors.
Overview
Specifications
| Parameter | Value |
|---|---|
| Transmittance [Dependent on Wavelength and Instrument Type] | 40% -80% |
| Blocking Depth | >OD6 |
| Diameter [Custom dimensions accepted] | 10, 12, 12.7, 15.0 |
| Thickness [Mounted in a Black Anodized Aluminum Ring] | 1~6 mm |
| Clear Aperture | >80% |
| Surface Quality | 80-50 |
| Reliability and Durability | MIL-STD-810F, MIL-C-48497A |
| Direction | The arrow on the ring indicates the recommended light propagation direction |
| CWL [CWL=340nm;FWHM=9nm] | 340 nm |
| FWHM [CWL=340nm;FWHM=9nm] | 9 nm |
| Tₚ [CWL=340nm;FWHM=9nm] | ≥40 % |
| Blocking Range [CWL=340nm;FWHM=9nm] | 200-1100 nm |
| Blocking Depth [CWL=340nm;FWHM=9nm] | OD6 |
| CWL [CWL=380nm;FWHM=10nm] | 380 nm |
| FWHM [CWL=380nm;FWHM=10nm] | 10 nm |
| Tₚ [CWL=380nm;FWHM=10nm] | ≥40 % |
| Blocking Range [CWL=380nm;FWHM=10nm] | 200-1100 nm |
| Blocking Depth [CWL=380nm;FWHM=10nm] | OD6 |
| CWL [CWL=405nm;FWHM=8nm] | 405 nm |
| FWHM [CWL=405nm;FWHM=8nm] | 8 nm |
| Tₚ [CWL=405nm;FWHM=8nm] | ≥40 % |
| Blocking Range [CWL=405nm;FWHM=8nm] | 200-1100 nm |
| Blocking Depth [CWL=405nm;FWHM=8nm] | OD6 |
| CWL [CWL=414nm;FWHM=8nm] | 414 nm |
| FWHM [CWL=414nm;FWHM=8nm] | 8 nm |
| Tₚ [CWL=414nm;FWHM=8nm] | ≥40 % |
| Blocking Range [CWL=414nm;FWHM=8nm] | 200-1100 nm |
| Blocking Depth [CWL=414nm;FWHM=8nm] | OD6 |
| CWL [CWL=450nm;FWHM=8nm] | 450 nm |
| FWHM [CWL=450nm;FWHM=8nm] | 8 nm |
| Tₚ [CWL=450nm;FWHM=8nm] | ≥45 % |
| Blocking Range [CWL=450nm;FWHM=8nm] | 200-1100 nm |
| Blocking Depth [CWL=450nm;FWHM=8nm] | OD6 |
| CWL [CWL=492nm;FWHM=10nm] | 492 nm |
| FWHM [CWL=492nm;FWHM=10nm] | 10 nm |
| Tₚ [CWL=492nm;FWHM=10nm] | ≥45 % |
| Blocking Range [CWL=492nm;FWHM=10nm] | 200-1100 nm |
| Blocking Depth [CWL=492nm;FWHM=10nm] | OD6 |
| CWL [CWL=505nm;FWHM=10nm] | 505 nm |
| FWHM [CWL=505nm;FWHM=10nm] | 10 nm |
| Tₚ [CWL=505nm;FWHM=10nm] | ≥45 % |
| Blocking Range [CWL=505nm;FWHM=10nm] | 200-1100 nm |
| Blocking Depth [CWL=505nm;FWHM=10nm] | OD6 |
| CWL [CWL=510nm;FWHM=10nm] | 510 nm |
| FWHM [CWL=510nm;FWHM=10nm] | 10 nm |
| Tₚ [CWL=510nm;FWHM=10nm] | ≥45 % |
| Blocking Range [CWL=510nm;FWHM=10nm] | 200-1100 nm |
| Blocking Depth [CWL=510nm;FWHM=10nm] | OD6 |
| CWL [CWL=535nm;FWHM=10nm] | 535 nm |
| FWHM [CWL=535nm;FWHM=10nm] | 10 nm |
| Tₚ [CWL=535nm;FWHM=10nm] | ≥45 % |
| Blocking Range [CWL=535nm;FWHM=10nm] | 200-1100 nm |
| Blocking Depth [CWL=535nm;FWHM=10nm] | OD6 |
| CWL [CWL=546nm;FWHM=10nm] | 546 nm |
| FWHM [CWL=546nm;FWHM=10nm] | 10 nm |
| Tₚ [CWL=546nm;FWHM=10nm] | ≥45 % |
| Blocking Range [CWL=546nm;FWHM=10nm] | 200-1100 nm |
| Blocking Depth [CWL=546nm;FWHM=10nm] | OD6 |
| CWL [CWL=578nm;FWHM=10nm] | 578 nm |
| FWHM [CWL=578nm;FWHM=10nm] | 10 nm |
| Tₚ [CWL=578nm;FWHM=10nm] | ≥45 % |
| Blocking Range [CWL=578nm;FWHM=10nm] | 200-1100 nm |
| Blocking Depth [CWL=578nm;FWHM=10nm] | OD6 |
| CWL [CWL=589nm;FWHM=10nm] | 589 nm |
| FWHM [CWL=589nm;FWHM=10nm] | 10 nm |
| Tₚ [CWL=589nm;FWHM=10nm] | ≥45 % |
| Blocking Range [CWL=589nm;FWHM=10nm] | 200-1100 nm |
| Blocking Depth [CWL=589nm;FWHM=10nm] | OD6 |
| CWL [CWL=600nm;FWHM=10nm] | 600 nm |
| FWHM [CWL=600nm;FWHM=10nm] | 10 nm |
| Tₚ [CWL=600nm;FWHM=10nm] | ≥45 % |
| Blocking Range [CWL=600nm;FWHM=10nm] | 200-1100 nm |
| Blocking Depth [CWL=600nm;FWHM=10nm] | OD6 |
| CWL [CWL=620nm;FWHM=10nm] | 620 nm |
| FWHM [CWL=620nm;FWHM=10nm] | 10 nm |
| Tₚ [CWL=620nm;FWHM=10nm] | ≥45 % |
| Blocking Range [CWL=620nm;FWHM=10nm] | 200-1100 nm |
| Blocking Depth [CWL=620nm;FWHM=10nm] | OD6 |
| CWL [CWL=630nm;FWHM=10nm] | 630 nm |
| FWHM [CWL=630nm;FWHM=10nm] | 10 nm |
| Tₚ [CWL=630nm;FWHM=10nm] | ≥45 % |
| Blocking Range [CWL=630nm;FWHM=10nm] | 200-1100 nm |
| Blocking Depth [CWL=630nm;FWHM=10nm] | OD6 |
| CWL [CWL=670nm;FWHM=10nm] | 670 nm |
| FWHM [CWL=670nm;FWHM=10nm] | 10 nm |
| Tₚ [CWL=670nm;FWHM=10nm] | ≥45 % |
| Blocking Range [CWL=670nm;FWHM=10nm] | 200-1100 nm |
| Blocking Depth [CWL=670nm;FWHM=10nm] | OD6 |
| CWL [CWL=690nm;FWHM=10nm] | 690 nm |
| FWHM [CWL=690nm;FWHM=10nm] | 10 nm |
| Tₚ [CWL=690nm;FWHM=10nm] | ≥45 % |
| Blocking Range [CWL=690nm;FWHM=10nm] | 200-1100 nm |
| Blocking Depth [CWL=690nm;FWHM=10nm] | OD6 |
| CWL [CWL=700nm;FWHM=10nm] | 700 nm |
| FWHM [CWL=700nm;FWHM=10nm] | 10 nm |
| Tₚ [CWL=700nm;FWHM=10nm] | ≥45 % |
| Blocking Range [CWL=700nm;FWHM=10nm] | 200-1100 nm |
| Blocking Depth [CWL=700nm;FWHM=10nm] | OD6 |
| CWL [CWL=800nm;FWHM=10nm] | 800 nm |
| FWHM [CWL=800nm;FWHM=10nm] | 10 nm |
| Tₚ [CWL=800nm;FWHM=10nm] | ≥50 % |
| Blocking Range [CWL=800nm;FWHM=10nm] | 200-1100 nm |
| Blocking Depth [CWL=800nm;FWHM=10nm] | OD6 |
Datasheet
Please provide your email to download the datasheet.
Invalid email format. Please try again.
Supplier Information
Loading...
Name
Phone
Organization
Use Case

Database Platform