Semiconductor Laser Pump Source V2-120-885-200
Vitality Laser V2-120-885-200 is a fiber-coupled semiconductor laser operating at 885 nm with 120 W continuous-wave output, designed for solid-state laser pumping and scientific research. Stable wavelength control, high electrical-to-optical efficiency and reliable thermal management suit industrial systems, laboratories and OEM integration. Features: 120 W CW output at 885 nm; narrow linewidth ≤0.5 nm and stable wavelength; electrical-to-optical efficiency 45% and slope efficiency 13 W/A; 200 μm fiber, NA 0.22 and SMA905 connector; operating current 10–11 A and voltage 23.5–24 V; enhanced thermal design with heat-dissipation capacity ≥240 W; long operating life.
Overview
Specifications
| Parameter | Value |
|---|---|
| Peak Output Power [All Parameter Tests Are Performed at 25°C.] | typical:120 W |
| Center Wavelength λ [All Parameter Tests Are Performed at 25°C.] | min:884.5 nm; typical:885 nm; max:885.5 nm |
| Spectral Full Width at Half Maximum FWHM [All Parameter Tests Are Performed at 25°C.] | typical:0.3 nm; max:0.5 nm |
| Wavelength Temperature Coefficient [All Parameter Tests Are Performed at 25°C.] | typical:0.02 nm/℃ |
| Fiber Numerical Aperture [All Parameter Tests Are Performed at 25°C.] | typical:0.22 |
| Fiber Core Diameter [All Parameter Tests Are Performed at 25°C.] | typical:200 µm |
| Connector Type [All Parameter Tests Are Performed at 25°C.] | typical:SMA905 |
| Fiber Length [All Parameter Tests Are Performed at 25°C.] | min:1.4 m; typical:1.5 m; max:1.6 m |
| Operating Current Iop [All Parameter Tests Are Performed at 25°C.] | typical:10 A; max:11 A |
| Threshold Current Ith [All Parameter Tests Are Performed at 25°C.] | typical:1.2 A |
| Operating Voltage Vop [All Parameter Tests Are Performed at 25°C.] | typical:23.5 V; max:24 V |
| Slope Efficiency [All Parameter Tests Are Performed at 25°C.] | typical:13 W/A |
| Electrical-to-Optical Conversion Efficiency [All Parameter Tests Are Performed at 25°C.] | typical:45 % |
| Wavelength-Stabilized Operating Current [All Parameter Tests Are Performed at 25°C.] | min:7 A; max:12 A |
| Operating Temperature [All Parameter Tests Are Performed at 25°C.] | min:20 ℃; max:30 ℃ |
| Operating Relative Humidity [All Parameter Tests Are Performed at 25°C.] | max:75 % |
| Storage Temperature [All Parameter Tests Are Performed at 25°C.] | min:-20 ℃; max:70 ℃ |
| Storage Relative Humidity [All Parameter Tests Are Performed at 25°C.] | min:5 %; max:85 % |
| Recommended Heat Dissipation Capacity [All Parameter Tests Are Performed at 25°C.] | typical:≥240 W |
Applications