BCSP-T manual/semiautomatic instruments measure curved-edge and small-hole transmittance in phone cover glass, including spherical, aspheric and plane samples. A collimated beam is focused through the sample into an integrating sphere; software computes spectra and judges results. A camera verifies measurement position. BCSP-FT is a fully automatic multihole IR-transmittance system for8-12in large screens, with automatic loading,unloading,measurement and OK/NG sorting.

Request a Quote Download Datasheet
Save to Favorites Save to Favorites

Overview

BCSP-T manual/semiautomatic instruments measure curved-edge and small-hole transmittance in phone cover glass, including spherical, aspheric and plane samples. A collimated beam is focused through the sample into an integrating sphere; software computes spectra and judges results. A camera verifies measurement position. BCSP-FT is a fully automatic multihole IR-transmittance system for8-12in large screens, with automatic loading,unloading,measurement and OK/NG sorting.

Specifications

ParameterValue
BCSP-III/T - Detection Range380nm-1100nm
BCSP-III/T - Wavelength Resolution0.5nm
BCSP-III/T - Signal-to-Noise Ratio500:1
BCSP-III/T - Stray Light0.05%@600nm 0.02%@400nm
BCSP-III/T - Relative Detection Error< 0.05%@550nm
BCSP-III/T - Measurement MethodTransmittance Relative to Air
BCSP-III/T - Single Measurement Time< 1s
BCSP-III/T - Wavelength Accuracy< 1nm
BCSP-III/T - Test Object Dimensions>0.3mm; Curved Edge 2R Can Be Measured
BCSP-III/T - ComputerOne Desktop Computer, Win7 Operating System
BCSP-III/T - SoftwareOne Set of BC Spectral Measurement Software
BCSP-III/T - Light SourceOne Broadband Light Source, Three Imported Assembled Bulbs, Bulb Lifetime 2000H
BCSP-III/T - Equipment WeightApproximately 30kg (External Light Source)
BCSP-III/T - Optical FiberOne Dedicated Optical Fiber
BCSP-III/T - Data CableOne Gold-Plated USB Cable
BCSP-III/T - Equipment Dimensions376(W)×554(D)×533(H)mm
BCSP-III/T - Operating EnvironmentLevel, Vibration-Free Location; Temperature: 23±5℃; Humidity: Below 60%, Non-Condensing
BCSP-III/T - Repeatability±0.3%(380nm-500nm)±0.05%(500nm-800nm) ±0.3%(800nm-1000nm)
BCSP-III/T - Integrating Sphere3mm, 1 Piece
BCSP-III/T - Objective5X, 1 Piece
BCSP-T - Detection Range380nm-1100nm
BCSP-T - Wavelength Resolution0.5nm
BCSP-T - Signal-to-Noise Ratio500:1
BCSP-T - Stray Light0.05%@600nm 0.02%@400nm
BCSP-T - Relative Detection Error< 0.05%@550nm
BCSP-T - Measurement MethodTransmittance Relative to Air
BCSP-T - Single Measurement Time< 1s
BCSP-T - Wavelength Accuracy< 1nm
BCSP-T - Test Object Dimensions>0.3mm; Curved Edge 2R Can Be Measured
BCSP-T - ComputerOne Desktop Computer, Win7 Operating System
BCSP-T - SoftwareOne Set of BC Spectral Measurement Software
BCSP-T - Light SourceOne Broadband Light Source, Three Imported Assembled Bulbs, Bulb Lifetime 2000H
BCSP-T - Equipment WeightApproximately 30kg (External Light Source)
BCSP-T - Optical FiberOne Dedicated Optical Fiber
BCSP-T - Data CableOne Gold-Plated USB Cable
BCSP-T - Equipment Dimensions376(W)×554(D)×533(H)mm
BCSP-T - Operating EnvironmentLevel, Vibration-Free Location; Temperature: 23±5℃; Humidity: Below 60%, Non-Condensing
BCSP-T - Repeatability±0.1%(380nm-500nm)±0.05%(500nm-800nm) ±0.1%(800nm-1000nm)
BCSP-T - Integrating Sphere100mm, One Piece
BCSP-T - Objective5X, 1 Piece; 10X, 1 Piece
BCSP-ST - Detection Range380nm-1100nm
BCSP-ST - Wavelength Resolution0.5nm
BCSP-ST - Signal-to-Noise Ratio500:1
BCSP-ST - Stray Light0.05%@600nm 0.02%@400nm
BCSP-ST - Relative Detection Error< 0.05%@550nm
BCSP-ST - Measurement MethodTransmittance Relative to Air
BCSP-ST - Repeatability±0.1%(380nm-500nm)±0.05%(500nm-800nm) ±0.1%(800nm-1000nm)
BCSP-ST - Maximum Speed6mm /sec
BCSP-ST - Repeat Positioning Accuracy1.5μm
BCSP-ST - Absolute Positioning Accuracy5μm
BCSP-ST - Single Measurement Time< 1s
BCSP-ST - Wavelength Accuracy< 1nm
BCSP-ST - Test Object Dimensions>0.3mm; Curved Edge 2R Can Be Measured
BCSP-ST - Integrating Sphere100mm, One Piece
BCSP-ST - Objective5X, 1 Piece; 10X, 1 Piece
BCSP-ST - ComputerOne Desktop Computer, Win7 Operating System
BCSP-ST - SoftwareOne Set of BC Spectral Measurement Software
BCSP-ST - Light SourceOne Broadband Light Source, Three Imported Assembled Bulbs, Bulb Lifetime 2000H
BCSP-ST - Equipment WeightApproximately 40kg (External Light Source)
BCSP-ST - Optical FiberOne Dedicated Optical Fiber
BCSP-ST - Data CableOne Gold-Plated USB Cable
BCSP-ST - Equipment Dimensions376(W)×554(D)×533(H)mm
BCSP-ST - Operating EnvironmentLevel, Vibration-Free Location; Temperature: 23±5℃; Humidity: Below 60%, Non-Condensing
BCSP-FT - Wavelength Detection Range400nm-1000nm
BCSP-FT - Wavelength Accuracy< 1nm
BCSP-FT - Wavelength Repeatability< 0.1nm
BCSP-FT - Transmittance Measurement MethodIntegrating Sphere Collection
BCSP-FT - Transmittance Repeatability±0.05%
BCSP-FT - Transmittance Measurement AccuracyError Less Than 0.3% Compared with the Reference Sample
BCSP-FT - Transmittance Resolution0.01%
BCSP-FT - Positioning MethodVisual Positioning (CCD Camera-Assisted Observation)
BCSP-FT - Positioning Accuracy0.03mm
BCSP-FT - Measurement Spot0.3/0.5 mm (0.5mm Default)
BCSP-FT - Product Pickup and Motion Method4-Axis SCARA Robot Gripping Motion
BCSP-FT - Gripping StructureManipulator with 400 Travel
BCSP-FT - Measurement SpeedSingle Hole: 700 Pieces/Hour
BCSP-FT - Single-Hole Inspection Speed< 0.5 s
BCSP-FT - Sample Size Range8-12 in screen products; two pieces per basket
BCSP-FT - Number of Loading and Unloading Trays40 Trays
BCSP-FT - NG Material HandlingNG Material Collected in a Separate Bin
BCSP-FT - Control SystemMotion Control Card Control
BCSP-FT - Warm-Up Time5 min
BCSP-FT - Alarm MechanismThree-Color Indicator + Buzzer
BCSP-FT - Light Source12V, 100W high-power tungsten-halogen lamp; lifetime 2000 hours
BCSP-FT - Equipment Dimensions2000 mm × 1340 mm × 1800 mm
BCSP-FT - Equipment Weight1200kg
BCSP-FT - Power Supply220V

Applications

Phone cover-glass small holes, curved edges, small optical components and automated large-screen IR-hole transmittance inspection.

Key Features

Manual/semiautomatic:380-1100nm. Focusing adjusts stage-to-optics distance from live/reference data differences; imaging visualizes the region. Ocean Optics MAYP2000PRO enables repeatable measurement within1s; collection optics receive all transmitted test light from curved samples. Two quick-switch probes measure0.3mm objects; visual positioning reduces hole-placement error. Automatic:40 trays each at input and output; camera alignment; one alignment followed by robot movement measures multiple holes. OK parts return to trays and NG parts to empty NG trays; automatic tray recovery. Four-axis SCARA picking,moving and placing; IR holes can lie on long or short edges.

Datasheet

Please provide your email to download the datasheet.

Your name
Email Address

Invalid email format. Please try again.

Send Request

Supplier Information

Bc
Bcoptical
View Supplier →
Guangdong Beichuang Optoelectronics Technology Co., Ltd. was established in 2009, headquartered in Chancheng District, Foshan City, Guangdong Province. After years of development and accumulation, the company now has overall supporting capabilities in R&D, manufacturing, and sales, mainly engaged in optical testing instruments, optical lenses, optical lenses, automation equipment, and technical services. The headquarters plays a key role as the center for R&D, planning, marketing, and capital operations. Its wholly-owned subsidiaries Beichuang Optoelectronics Technology (Shaoyang) Co., Ltd., Foshan Lianyi Optical Co., Ltd., and the lens factory are the company's main manufacturing bases, with steadily improving manufacturing capabilities. Its holding subsidiary Foshan Quying Technology Co., Ltd. focuses on the R&D and production of projector lenses, independently developing more than 50 types of projector lenses and more than 100 types of security lenses. With high-quality service levels, it serves related enterprises at home and abroad, providing strong support for the company's development. With the continuous improvement of corporate governance structure and standardization, the company has attracted many investment institutions, professional technical talents, and management talents to join. Development is the theme we are facing directly. The pace of innovation has never stopped. The company has independently developed and designed multiple optical lenses, spectral analysis instruments, and non-contact thickness measuring instruments, which have been widely used in many optical production enterprises and scientific research units at home and abroad and are well received. As a national high-tech enterprise, all our products are independently developed and produced, and we own independent intellectual property rights. Talent is the key to success. Building a stronger team is the focus of our current work. We are willing to strive for self-improvement and provide better products and services to our customers.

Request a Quote

Our team responds within 24–48 hours
BCSP-T Series Manual and Semiautomatic Curved-Edge Transmittance Spectral Analyzer
Bcoptical · Optical Spectrum Analyzers
Direct from Manufacturer
Your inquiry will be sent directly to the manufacturer
Photonics Source Platform
We handles the inquiry on your behalf
Your information is protected and will never be shared without consent.
Contact Us

Loading...

GetExperimental Plan

Name

Phone

+86

Organization

Use Case

AI Parametric Selection
Smart Match · Precise Recs
Enter Specifications
AI Smart Matching
Get Best Matches
Skip Manual Comparison
Find Best Solutions Fast
Select Now →