Extractive gas analysis RS2600PAT
The RS2600PAT multicomponent gas analyzer is a highly sensitive online instrument with a pressurized explosion-protected design for direct industrial installation. It simultaneously analyzes multiple gases across many applications: hydrocarbons such as CH₄, C₂H₆, C₃H₈ and C₂H₄ in petrochemicals; corrosive gases such as F₂, BF₃, PF₅, HCl and HF in fluorine chemistry; N₂, H₂, O₂, CO₂ and CO in metallurgy; and isotopic gases including H₂, D₂, T₂, HD, HT and DT. A multivariate calibration-curve model combined with chemometrics relates spectral peak intensity or area to component concentrations. Changes in sample pressure or measurement conditions do not affect quantitative accuracy, and separate models for each component are unnecessary. A supporting multipath gas pretreatment system enables sequential analysis at multiple sampling points.
Overview
Specifications
| Parameter | Value |
|---|---|
| Technical principle | Laser Raman spectroscopy |
| Measurement Method | Bypass real-time analysis; the sampling line carries the gas to be measured to the analyzer cabinet |
| Number of detection channels | The analyzer has a single channel and can be equipped with a multistream gas pretreatment system for online analysis of multiple gas streams |
| Detection sensitivity | ppm level |
| Equipment mounting method | Chassis installation:485 mm (width)×350 mm (height)×600 mm (depth); explosion-proof cabinet installation:800mm deep×900mm wide×1300mm high, suitable for direct installation at the production site |
| Gas sampling method | Sampling line (optional heat tracing and thermal insulation) |
| Gas inlet/outlet connection | Standard compression fitting;3mm,6mm,1/8” and1/4” optional |
| Inlet gas temperature requirements | -50~40℃; if the sample gas is above this temperature, it must be cooled before entering the analyzer for testing |
| Inlet gas pressure requirements | <1.0 MPa; if the sample gas is above this pressure, its pressure must be reduced before entering the analyzer for testing |
| Electrical supply requirements | 100~240 VAC,50~60 Hz |
| Operating temperature | Chassis installation: 5~35°; explosion-proof cabinet installation: -20~50° |
| Operating humidity | 0~90%RH |
| Communication Method | DB9 RS485 |
| 24h Operating | Built-in real-time automatic calibration and self-test, constant-temperature control, and positive-pressure protection. Operates normally at high and low temperatures and in explosive and corrosive environments. |