(2+1)x1 Pump & Signal Combiner MCPSC-21-F-1064-915/25-105/125/22-H1-10/125/08D-10-2

(2+1)x1 Pump & Signal Combiner MCPSC-21-F-1064-915/25-105/125/22-H1-10/125/08D-10-2

Supplier
Mchlight
Part Number
MCPSC-21-F-1064-915/25-105/125/22-H1-10/125/08D-10-2
Category
Fiber Combiners
Origin
China

The (2+1)x1 multimode pump & signal combiner is designed for high-power fiber lasers and amplifiers. It combines 2 multimode pump channels and 1 signal channel into one double-clad fiber. Signal light travels in the core and pump light in the cladding, enabling simultaneous transmission. High pump efficiency, low insertion loss, stable reliable performance and per-arm power handling up to 300W are provided.

Specification Snapshot
Isolation [Temperature measurement ambient conditions: 25℃; Signal wavelength range =1020-1080/1530-1575/1950-2050]
20 dB
Operating temperature [Signal wavelength range =1020-1080/1530-1575/1950-2050]
0~+75 ℃
Storage temperature [Signal wavelength range =1020-1080/1530-1575/1950-2050]
-40~+85 ℃
Request a Quote Download Datasheet
Save to Favorites Save to Favorites

Overview

The (2+1)x1 multimode pump & signal combiner is designed for high-power fiber lasers and amplifiers. It combines 2 multimode pump channels and 1 signal channel into one double-clad fiber. Signal light travels in the core and pump light in the cladding, enabling simultaneous transmission. High pump efficiency, low insertion loss, stable reliable performance and per-arm power handling up to 300W are provided.

Specifications

ParameterValue
Structure Type [Signal wavelength range =1020-1080/1530-1575/1950-2050](2+1)x1
Signal wavelength range [Temperature measurement ambient conditions: 25℃; Signal wavelength range =1020-1080]1020-1080 nm
Signal wavelength range [Temperature measurement ambient conditions: 25℃; Signal wavelength range =1530-1575]1530-1575 nm
Signal wavelength range [Temperature measurement ambient conditions: 25℃; Signal wavelength range =1950-2050]1950-2050 nm
Pump wavelength range [Temperature measurement ambient conditions: 25℃; Signal wavelength range =1020-1080/1530-1575/1950-2050]780-1000 nm
Pump Fiber type [Signal wavelength range =1020-1080/1530-1575/1950-2050]105/125um NA0.22
Signal input Fiber type [Signal wavelength range =1020-1080]10/125um NA0.08/0.46
Signal input Fiber type [Signal wavelength range =1530-1575]9/125um,NA0.12/0.46
Signal input Fiber type [Signal wavelength range =1950-2050]10/130um,NA0.15/0.46
Output Fiber Type [Signal wavelength range =1020-1080]10/125um NA0.08/0.46
Output Fiber Type [Signal wavelength range =1530-1575]9/125um,NA0.12/0.46
Output Fiber Type [Signal wavelength range =1950-2050]10/130um,NA0.15/0.46
Signal Insertion loss ( Max ) [Temperature measurement ambient conditions: 25℃; Max ; Signal wavelength range =1020-1080/1530-1575/1950-2050]0.5 dB
Pump Efficiency ( Min ) [Temperature measurement ambient conditions: 25℃; Min ; Signal wavelength range =1020-1080/1530-1575/1950-2050]90 %
Single-Arm Input Power [Temperature measurement ambient conditions: 25℃; Signal wavelength range =1020-1080/1530-1575/1950-2050]50 W
M² [Temperature measurement ambient conditions: 25℃; Signal wavelength range =1020-1080/1530-1575/1950-2050]<1.3
Isolation [Temperature measurement ambient conditions: 25℃; Signal wavelength range =1020-1080/1530-1575/1950-2050]20 dB
Fiber length [Signal wavelength range =1020-1080/1530-1575/1950-2050]0.8 or other
Package dimensions [Package dimensions differ with power; contact us to confirm specifications; signal wavelength range=1020-1080/1530-1575/1950-2050]P2:65x12x7 or P3:80x12x8
Operating temperature [Signal wavelength range =1020-1080/1530-1575/1950-2050]0~+75 ℃
Storage temperature [Signal wavelength range =1020-1080/1530-1575/1950-2050]-40~+85 ℃
max [Temperature measurement ambient conditions: 25℃; max; Type : (2+1)x1; Signal Wavelength (nm): 1020-1080; Pump fiber : 105/125 0.22; Signal input fiber : Hi1060(1060-XP); Output fiber : 5/130um,NA0.12/0.46]0.5dB
min [Temperature measurement ambient conditions: 25℃; min; Type : (2+1)x1; Signal Wavelength (nm): 1020-1080; Pump fiber : 105/125 0.22; Signal input fiber : Hi1060(1060-XP); Output fiber : 5/130um,NA0.12/0.46]90%
max [Temperature measurement ambient conditions: 25℃; max; Type : (2+1)x1; Signal Wavelength (nm): 1020-1080; Pump fiber : 105/125 0.22; Signal input fiber : Hi1060(1060-XP); Output fiber : 5/130um,NA0.12/0.46]50W
max [Temperature measurement ambient conditions: 25℃; max; Type : (2+1)x1; Signal Wavelength (nm): 1020-1080; Pump fiber : 105/125 0.22; Signal input fiber : Hi1060(1060-XP); Output fiber : 10/125um,NA0.08/0.46]0.5dB
min [Temperature measurement ambient conditions: 25℃; min; Type : (2+1)x1; Signal Wavelength (nm): 1020-1080; Pump fiber : 105/125 0.22; Signal input fiber : Hi1060(1060-XP); Output fiber : 10/125um,NA0.08/0.46]90%
max [Temperature measurement ambient conditions: 25℃; max; Type : (2+1)x1; Signal Wavelength (nm): 1020-1080; Pump fiber : 105/125 0.22; Signal input fiber : Hi1060(1060-XP); Output fiber : 10/125um,NA0.08/0.46]50W
max [Temperature measurement ambient conditions: 25℃; max; Type : (2+1)x1; Signal Wavelength (nm): 1020-1080; Pump fiber : 105/125 0.22; Signal input fiber : Hi1060(1060-XP); Output fiber : 20/125um,NA0.08/0.46]0.5dB
min [Temperature measurement ambient conditions: 25℃; min; Type : (2+1)x1; Signal Wavelength (nm): 1020-1080; Pump fiber : 105/125 0.22; Signal input fiber : Hi1060(1060-XP); Output fiber : 20/125um,NA0.08/0.46]90%
max [Temperature measurement ambient conditions: 25℃; max; Type : (2+1)x1; Signal Wavelength (nm): 1020-1080; Pump fiber : 105/125 0.22; Signal input fiber : Hi1060(1060-XP); Output fiber : 20/125um,NA0.08/0.46]50W
max [Temperature measurement ambient conditions: 25℃; max; Type : (2+1)x1; Signal Wavelength (nm): 1020-1080; Pump fiber : 105/125 0.22; Signal input fiber : 5/130um,NA0.12/0.46; Output fiber : 6/125um,NA0.18/0.46]0.5dB
min [Temperature measurement ambient conditions: 25℃; min; Type : (2+1)x1; Signal Wavelength (nm): 1020-1080; Pump fiber : 105/125 0.22; Signal input fiber : 5/130um,NA0.12/0.46; Output fiber : 6/125um,NA0.18/0.46]90%
max [Temperature measurement ambient conditions: 25℃; max; Type : (2+1)x1; Signal Wavelength (nm): 1020-1080; Pump fiber : 105/125 0.22; Signal input fiber : 5/130um,NA0.12/0.46; Output fiber : 6/125um,NA0.18/0.46]50W
max [Temperature measurement ambient conditions: 25℃; max; Type : (2+1)x1; Signal Wavelength (nm): 1020-1080; Pump fiber : 105/125 0.22; Signal input fiber : 5/130um,NA0.12/0.46; Output fiber : 10/125um,NA0.08/0.46]0.5dB
min [Temperature measurement ambient conditions: 25℃; min; Type : (2+1)x1; Signal Wavelength (nm): 1020-1080; Pump fiber : 105/125 0.22; Signal input fiber : 5/130um,NA0.12/0.46; Output fiber : 10/125um,NA0.08/0.46]90%
max [Temperature measurement ambient conditions: 25℃; max; Type : (2+1)x1; Signal Wavelength (nm): 1020-1080; Pump fiber : 105/125 0.22; Signal input fiber : 5/130um,NA0.12/0.46; Output fiber : 10/125um,NA0.08/0.46]50W
max [Temperature measurement ambient conditions: 25℃; max; Type : (2+1)x1; Signal Wavelength (nm): 1020-1080; Pump fiber : 105/125 0.22; Signal input fiber : 5/130um,NA0.12/0.46; Output fiber : 20/125um,NA0.08/0.46]0.5dB
min [Temperature measurement ambient conditions: 25℃; min; Type : (2+1)x1; Signal Wavelength (nm): 1020-1080; Pump fiber : 105/125 0.22; Signal input fiber : 5/130um,NA0.12/0.46; Output fiber : 20/125um,NA0.08/0.46]90%
max [Temperature measurement ambient conditions: 25℃; max; Type : (2+1)x1; Signal Wavelength (nm): 1020-1080; Pump fiber : 105/125 0.22; Signal input fiber : 5/130um,NA0.12/0.46; Output fiber : 20/125um,NA0.08/0.46]50W
max [Temperature measurement ambient conditions: 25℃; max; Type : (2+1)x1; Signal Wavelength (nm): 1020-1080; Pump fiber : 105/125 0.22; Signal input fiber : 6/125um,NA0.18/0.46; Output fiber : 6/125um,NA0.18/0.46]0.5dB
min [Temperature measurement ambient conditions: 25℃; min; Type : (2+1)x1; Signal Wavelength (nm): 1020-1080; Pump fiber : 105/125 0.22; Signal input fiber : 6/125um,NA0.18/0.46; Output fiber : 6/125um,NA0.18/0.46]90%
max [Temperature measurement ambient conditions: 25℃; max; Type : (2+1)x1; Signal Wavelength (nm): 1020-1080; Pump fiber : 105/125 0.22; Signal input fiber : 6/125um,NA0.18/0.46; Output fiber : 6/125um,NA0.18/0.46]50W
max [Temperature measurement ambient conditions: 25℃; max; Type : (2+1)x1; Signal Wavelength (nm): 1020-1080; Pump fiber : 105/125 0.22; Signal input fiber : 10/125um,NA0.08/0.46; Output fiber : 10/125um,NA0.08/0.46]0.5dB
min [Temperature measurement ambient conditions: 25℃; min; Type : (2+1)x1; Signal Wavelength (nm): 1020-1080; Pump fiber : 105/125 0.22; Signal input fiber : 10/125um,NA0.08/0.46; Output fiber : 10/125um,NA0.08/0.46]90%
max [Temperature measurement ambient conditions: 25℃; max; Type : (2+1)x1; Signal Wavelength (nm): 1020-1080; Pump fiber : 105/125 0.22; Signal input fiber : 10/125um,NA0.08/0.46; Output fiber : 10/125um,NA0.08/0.46]50W
max [Temperature measurement ambient conditions: 25℃; max; Type : (2+1)x1; Signal Wavelength (nm): 1020-1080; Pump fiber : 105/125 0.22; Signal input fiber : 10/125um,NA0.08/0.46; Output fiber : 20/125um,NA0.08/0.46]0.5dB
min [Temperature measurement ambient conditions: 25℃; min; Type : (2+1)x1; Signal Wavelength (nm): 1020-1080; Pump fiber : 105/125 0.22; Signal input fiber : 10/125um,NA0.08/0.46; Output fiber : 20/125um,NA0.08/0.46]90%
max [Temperature measurement ambient conditions: 25℃; max; Type : (2+1)x1; Signal Wavelength (nm): 1020-1080; Pump fiber : 105/125 0.22; Signal input fiber : 10/125um,NA0.08/0.46; Output fiber : 20/125um,NA0.08/0.46]50W
max [Temperature measurement ambient conditions: 25℃; max; Type : (2+1)x1; Signal Wavelength (nm): 1020-1080; Pump fiber : 105/125 0.22; Signal input fiber : 20/125um,NA0.08/0.46; Output fiber : 20/125um,NA0.08/0.46]0.5dB
min [Temperature measurement ambient conditions: 25℃; min; Type : (2+1)x1; Signal Wavelength (nm): 1020-1080; Pump fiber : 105/125 0.22; Signal input fiber : 20/125um,NA0.08/0.46; Output fiber : 20/125um,NA0.08/0.46]90%
max [Temperature measurement ambient conditions: 25℃; max; Type : (2+1)x1; Signal Wavelength (nm): 1020-1080; Pump fiber : 105/125 0.22; Signal input fiber : 20/125um,NA0.08/0.46; Output fiber : 20/125um,NA0.08/0.46]100W
max [Temperature measurement ambient conditions: 25℃; max; Type : (2+1)x1; Signal Wavelength (nm): 1020-1080; Pump fiber : 105/125 0.22; Signal input fiber : 10/125um,NA0.08/0.46; Output fiber : 25/250um,NA0.065/0.46]0.5dB
min [Temperature measurement ambient conditions: 25℃; min; Type : (2+1)x1; Signal Wavelength (nm): 1020-1080; Pump fiber : 105/125 0.22; Signal input fiber : 10/125um,NA0.08/0.46; Output fiber : 25/250um,NA0.065/0.46]95%
max [Temperature measurement ambient conditions: 25℃; max; Type : (2+1)x1; Signal Wavelength (nm): 1020-1080; Pump fiber : 105/125 0.22; Signal input fiber : 10/125um,NA0.08/0.46; Output fiber : 25/250um,NA0.065/0.46]200W
max [Temperature measurement ambient conditions: 25℃; max; Type : (2+1)x1; Signal Wavelength (nm): 1020-1080; Pump fiber : 200/220 0.22; Signal input fiber : 25/250um,NA0.065/0.46; Output fiber : 25/250um,NA0.065/0.46]0.5dB
min [Temperature measurement ambient conditions: 25℃; min; Type : (2+1)x1; Signal Wavelength (nm): 1020-1080; Pump fiber : 200/220 0.22; Signal input fiber : 25/250um,NA0.065/0.46; Output fiber : 25/250um,NA0.065/0.46]95%
max [Temperature measurement ambient conditions: 25℃; max; Type : (2+1)x1; Signal Wavelength (nm): 1020-1080; Pump fiber : 200/220 0.22; Signal input fiber : 25/250um,NA0.065/0.46; Output fiber : 25/250um,NA0.065/0.46]200W
max [Temperature measurement ambient conditions: 25℃; max; Type : (2+1)x1; Signal Wavelength (nm): 1020-1080; Pump fiber : 200/220 0.22; Signal input fiber : 30/250um,NA0.062/0.46; Output fiber : 30/250um,NA0.062/0.46]0.5dB
min [Temperature measurement ambient conditions: 25℃; min; Type : (2+1)x1; Signal Wavelength (nm): 1020-1080; Pump fiber : 200/220 0.22; Signal input fiber : 30/250um,NA0.062/0.46; Output fiber : 30/250um,NA0.062/0.46]95%
max [Temperature measurement ambient conditions: 25℃; max; Type : (2+1)x1; Signal Wavelength (nm): 1020-1080; Pump fiber : 200/220 0.22; Signal input fiber : 30/250um,NA0.062/0.46; Output fiber : 30/250um,NA0.062/0.46]200W
max [Temperature measurement ambient conditions: 25℃; max; Type : (2+1)x1; Signal Wavelength (nm): 1020-1080; Pump fiber : 200/220 0.22; Signal input fiber : 20/400um,NA0.065/0.46; Output fiber : 20/400um,NA0.065/0.46]0.5dB
min [Temperature measurement ambient conditions: 25℃; min; Type : (2+1)x1; Signal Wavelength (nm): 1020-1080; Pump fiber : 200/220 0.22; Signal input fiber : 20/400um,NA0.065/0.46; Output fiber : 20/400um,NA0.065/0.46]95%
max [Temperature measurement ambient conditions: 25℃; max; Type : (2+1)x1; Signal Wavelength (nm): 1020-1080; Pump fiber : 200/220 0.22; Signal input fiber : 20/400um,NA0.065/0.46; Output fiber : 20/400um,NA0.065/0.46]300W
max [Temperature measurement ambient conditions: 25℃; max; Type : (2+1)x1; Signal Wavelength (nm): 1530-1575; Pump fiber : 105/125 0.22; Signal input fiber : SMF-28e; Output fiber : SM-GDF-1550]0.5dB
min [Temperature measurement ambient conditions: 25℃; min; Type : (2+1)x1; Signal Wavelength (nm): 1530-1575; Pump fiber : 105/125 0.22; Signal input fiber : SMF-28e; Output fiber : SM-GDF-1550]90%
max [Temperature measurement ambient conditions: 25℃; max; Type : (2+1)x1; Signal Wavelength (nm): 1530-1575; Pump fiber : 105/125 0.22; Signal input fiber : SMF-28e; Output fiber : SM-GDF-1550]50W
max [Temperature measurement ambient conditions: 25℃; max; Type : (2+1)x1; Signal Wavelength (nm): 1530-1575; Pump fiber : 105/125 0.22; Signal input fiber : SM-GDF-1550; Output fiber : SM-GDF-1550]0.5dB
min [Temperature measurement ambient conditions: 25℃; min; Type : (2+1)x1; Signal Wavelength (nm): 1530-1575; Pump fiber : 105/125 0.22; Signal input fiber : SM-GDF-1550; Output fiber : SM-GDF-1550]90%
max [Temperature measurement ambient conditions: 25℃; max; Type : (2+1)x1; Signal Wavelength (nm): 1530-1575; Pump fiber : 105/125 0.22; Signal input fiber : SM-GDF-1550; Output fiber : SM-GDF-1550]50W
max [Temperature measurement ambient conditions: 25℃; max; Type : (2+1)x1; Signal Wavelength (nm): 1530-1575; Pump fiber : 105/125 0.22; Signal input fiber : 12/130um,NA0.20/0.46; Output fiber : 12/130um,NA0.20/0.46]0.5dB
min [Temperature measurement ambient conditions: 25℃; min; Type : (2+1)x1; Signal Wavelength (nm): 1530-1575; Pump fiber : 105/125 0.22; Signal input fiber : 12/130um,NA0.20/0.46; Output fiber : 12/130um,NA0.20/0.46]90%
max [Temperature measurement ambient conditions: 25℃; max; Type : (2+1)x1; Signal Wavelength (nm): 1530-1575; Pump fiber : 105/125 0.22; Signal input fiber : 12/130um,NA0.20/0.46; Output fiber : 12/130um,NA0.20/0.46]50W
max [Temperature measurement ambient conditions: 25℃; max; Type : (2+1)x1; Signal Wavelength (nm): 1530-1575; Pump fiber : 105/125 0.22; Signal input fiber : 12/130um,NA0.20/0.46; Output fiber : 25/300um,NA0.09/0.46]0.5dB
min [Temperature measurement ambient conditions: 25℃; min; Type : (2+1)x1; Signal Wavelength (nm): 1530-1575; Pump fiber : 105/125 0.22; Signal input fiber : 12/130um,NA0.20/0.46; Output fiber : 25/300um,NA0.09/0.46]95%
max [Temperature measurement ambient conditions: 25℃; max; Type : (2+1)x1; Signal Wavelength (nm): 1530-1575; Pump fiber : 105/125 0.22; Signal input fiber : 12/130um,NA0.20/0.46; Output fiber : 25/300um,NA0.09/0.46]100W
max [Temperature measurement ambient conditions: 25℃; max; Type : (2+1)x1; Signal Wavelength (nm): 1950-2050; Pump fiber : 105/125 0.22; Signal input fiber : SM1950; Output fiber : 10/130um,NA0.15/0.46]0.5dB
min [Temperature measurement ambient conditions: 25℃; min; Type : (2+1)x1; Signal Wavelength (nm): 1950-2050; Pump fiber : 105/125 0.22; Signal input fiber : SM1950; Output fiber : 10/130um,NA0.15/0.46]90%
max [Temperature measurement ambient conditions: 25℃; max; Type : (2+1)x1; Signal Wavelength (nm): 1950-2050; Pump fiber : 105/125 0.22; Signal input fiber : SM1950; Output fiber : 10/130um,NA0.15/0.46]50W
max [Temperature measurement ambient conditions: 25℃; max; Type : (2+1)x1; Signal Wavelength (nm): 1950-2050; Pump fiber : 105/125 0.22; Signal input fiber : 10/130um,NA0.15/0.46; Output fiber : 10/130um,NA0.15/0.46]0.5dB
min [Temperature measurement ambient conditions: 25℃; min; Type : (2+1)x1; Signal Wavelength (nm): 1950-2050; Pump fiber : 105/125 0.22; Signal input fiber : 10/130um,NA0.15/0.46; Output fiber : 10/130um,NA0.15/0.46]90%
max [Temperature measurement ambient conditions: 25℃; max; Type : (2+1)x1; Signal Wavelength (nm): 1950-2050; Pump fiber : 105/125 0.22; Signal input fiber : 10/130um,NA0.15/0.46; Output fiber : 10/130um,NA0.15/0.46]50W
max [Temperature measurement ambient conditions: 25℃; max; Type : (2+1)x1; Signal Wavelength (nm): 1950-2050; Pump fiber : 105/125 0.22; Signal input fiber : 10/130um,NA0.15/0.46; Output fiber : 25/250um,NA0.09/0.46]0.7dB
min [Temperature measurement ambient conditions: 25℃; min; Type : (2+1)x1; Signal Wavelength (nm): 1950-2050; Pump fiber : 105/125 0.22; Signal input fiber : 10/130um,NA0.15/0.46; Output fiber : 25/250um,NA0.09/0.46]95%
max [Temperature measurement ambient conditions: 25℃; max; Type : (2+1)x1; Signal Wavelength (nm): 1950-2050; Pump fiber : 105/125 0.22; Signal input fiber : 10/130um,NA0.15/0.46; Output fiber : 25/250um,NA0.09/0.46]100W
max [Temperature measurement ambient conditions: 25℃; max; Type : (2+1)x1; Signal Wavelength (nm): 1950-2050; Pump fiber : 105/125 0.22; Signal input fiber : 10/130um,NA0.15/0.46; Output fiber : 25/400um,NA0.09/0.46]0.7dB
min [Temperature measurement ambient conditions: 25℃; min; Type : (2+1)x1; Signal Wavelength (nm): 1950-2050; Pump fiber : 105/125 0.22; Signal input fiber : 10/130um,NA0.15/0.46; Output fiber : 25/400um,NA0.09/0.46]95%
max [Temperature measurement ambient conditions: 25℃; max; Type : (2+1)x1; Signal Wavelength (nm): 1950-2050; Pump fiber : 105/125 0.22; Signal input fiber : 10/130um,NA0.15/0.46; Output fiber : 25/400um,NA0.09/0.46]100W
Package dimensions [Package dimensions : P1]50 mm × 5 mm × 5 mm
Package dimensions [Package dimensions : P2]65 mm × 12 mm × 7 mm
Package dimensions [Package dimensions : P3]80 mm × 12 mm × 8 mm
Package dimensions [Package dimensions : P4]100 mm × 15 mm × 10 mm

Applications

Fiber lasers; fiber amplifiers; fiber optic communications

Key Features

Low insertion loss; broad wavelength range/high power handling; high stability and reliability

Datasheet

Product Datasheet
PDF
Download

Supplier Information

Mc
Mchlight
View Supplier →
Shenzhen MCHLight Photoelectric Co., Ltd. was established in 2012, with its headquarters located in Guangming District, Shenzhen. It is a specialized and innovative small and medium-sized enterprise in Shenzhen, and has passed the ISO9001-2015 quality management system certification. After years of continuous R&D investment and focused development, MCHLight has become a comprehensive fiber optic product service provider in fields such as fiber lasers, LiDAR, fiber sensing, laser medical treatment, and laser communication. The company currently has a fiber optic device R&D and production center and a laser R&D and production center. The fiber optic device R&D and production center is equipped with standard cleanrooms and can provide high-power fiber devices, polarization-maintaining fiber devices, and ultra-small fiber devices at various wavelengths. The laser R&D center develops and produces laser light sources at special wavelengths, fiber lasers, fiber amplifiers, and conducts technical research and reserves for new products. The R&D and production centers cooperate with scientific research institutions in multiple locations, enabling them to quickly and efficiently provide customers with devices, equipment, systems, and cost-effective solutions in related fields. "Mingxin Tongde, Innovation and Pragmatism" is the purpose and philosophy of MCHLight. Over the years, with a high-quality management team and an innovative work philosophy, the company has persisted in R&D in specialized and customized product fields, overcome difficulties, and its products have been highly recognized by the industry and partners. With continuous investment in product R&D and solution design, and with strict control of product quality and the pursuit of excellence, MCHLight creates greater value for customers.

Request a Quote

Our team responds within 24–48 hours
(2+1)x1 Pump & Signal Combiner MCPSC-21-F-1064-915/25-105/125/22-H1-10/125/08D-10-2
Mchlight · Fiber Combiners
Direct from Manufacturer
Your inquiry will be sent directly to the manufacturer
Photonics Source Platform
We handles the inquiry on your behalf
Your information is protected and will never be shared without consent.
Contact Us

Loading...

GetExperimental Plan

Name

Phone

+86

Organization

Use Case

AI Parametric Selection
Smart Match · Precise Recs
Enter Specifications
AI Smart Matching
Get Best Matches
Skip Manual Comparison
Find Best Solutions Fast
Select Now →