High- and Low-Temperature Rapid Temperature Change Test Chamber RK-THX-408
The rapid high/low-temperature chamber offers customizable linear/nonlinear rates of 5℃/min~25℃/min. In-house controls, precision refrigeration design and manufacturing provide stability, efficiency and energy savings. Intelligent electronic expansion valves adjust refrigerant flow and electric-heating power (%) to load, matching automatic simulated heating/cooling output. A cascade compressor/condenser/evaporator/throttling system provides rapid cooling, while heaters provide rapid heating. Test purpose: Identify component operating and storage temperatures and approach design temperature limits and repeatedly expose products to severe conditions to reveal faults from latent design, manufacturing and component defects. Detecting and removing early failures allows delivery at the inherent reliability level, in the random-failure phase, ensuring quality.
Overview
Specifications
| Parameter | Value |
|---|---|
| Capacity | 408L |
| Internal dimensions W*H*D | 600 mm × 850 mm × 800 mm |
| External dimensions W*H*D | 820 mm × 1850 mm × 1570 mm |
| Temperature Range | -70~180°C( optional :-60~180°C,-40~180°C) |
| Heating rate [Linear; Customizable] | 10°C/min Linear (Customizable) |
| Cooling Rate [Linear; Customizable] | 5°C/min Linear (Customizable) |
| Temperature Fluctuation [No load Steady state] | ≤±0.2°C( No load Steady state ) |
| Temperature Deviation [No load Steady state] | ≤±2.0°C( No load Steady state ) |
| Temperature Uniformity [No load Steady state] | ≤±1.0°C( No load Steady state ) |
| Humidity Range [(+10°C~+95)°C] | 10%R.H~98%R.H |
| Humidity Fluctuation [No load Steady state] | ±2.0%RH( No load Steady state ) |
| Humidity Deviation [No load Steady state] | ±3.0%RH( No load Steady state ) |
| Humidity Uniformity [No load Steady state] | ≤5.0%RH( No load Steady state ) |
| Temperature Change Rate - Heating Rate [-55~+85°C Average over the Entire Range] | Not less than 2.0°C/min |
| Temperature Change Rate - Cooling Rate [+85~-55°C Average over the Entire Range] | Not less than 2.0°C/min |
| Cooling method | Air cooling ( or Water cooling ) |
| Energy-Saving Method | Hot-gas bypass technology + cold-side self-balancing technology |
| Inner chamber Material [Customizable SUS316 Mirror-Finish Stainless Steel] | SUS304 mirror-finish stainless steel (custom SUS316 mirror-finish stainless steel available) |
| Outer box material | Cold-rolled steel plate with an electrostatically sprayed surface finish |
| Refrigeration System | Dual/cascade refrigeration system + piston compressor + environmentally friendly R-404a/R-23 refrigerants |
| Water supply method | Extra-large water tank + automatic water replenishment |
| Controller | 10-inch industrial true-color touchscreen + Siemens PLC, Pacoologic temperature-control module, selectable Chinese and English |
| Protective device | Compressor overpressure, overcurrent, overheating and differential-oil-pressure protection; chamber overtemperature protection; heater dry-run protection; overcurrent trip; humidifier dry-run protection; fan overcurrent protection; leakage-current protection; tank low-water protection |
| Operating environment - Temperature | +5°C~+35°C |
| Operating environment - Power supply [Customizable Other Power Supply Specifications] | Three-Phase 380V 50HZ( Customizable Other Power Supply Specifications ) |
| Meets Standard | GB2423.1/IEC60068-2-1;GB/T2423.2/IEC60068-2-2;GB/T2423.3/IEC60068-2-78;GB/T2423.4/IEC60068-2-30;GB/T2423.22/IEC60068-2-14;GJB150.3;GJB150.4;GJB150.9;GB/T5170.18;GB/T10586;GB/T10589 |