Fully Automatic Microscopic Transmission/Reflection Measurement Instrument
Sunny large microscope stand with an 8-megapixel camera and automatic xy stage. Resolution is 1um, effective motorized measurement area 70mm*70mm, and measured spot size under a 50× objective is 4 micrometers. Demonstrated leaf reflectance measurement, 350-1000nm spectral range, software-controlled automatic microscale scanning and hyperspectral capability. Introduction: Full-spectrum measurement across 380nm~950nm combines microscopy and motorized stages for fast, fine-resolution visible-band measurements. It measures small regions and curved-surface reflectance unavailable to ordinary spectrophotometers, suiting optics and miniature electronics. One instrument measures reflectance, transmittance and film thickness. Reflectance: Objective-focused Φ17~70μm spots. Film thickness: Reflectance data determine single-/multilayer thickness from about 50nm to about 100μm. Transmittance: Ø2mm parallel illumination through the stage measures planar samples. High speed: A plane grating and line sensor measure all wavelengths simultaneously.
Overview
Specifications
| Parameter | Value |
|---|---|
| Measurement Function | Transmittance, Reflectance and Film Thickness |
| Illumination Reception Conditions [Transmission] | Transmission : Vertical Illumination Vertical Reception |
| Illumination Reception Conditions [Reflection] | Reflection: 8-Degree Illumination with Perpendicular Reception (Integrating-Sphere Method) |
| Wavelength Range | 380-950nm |
| Spot size [Transmission] | Transmission :φ0.1-5mm adjustable |
| Spot size [Reflection] | Reflection :φ1-5mm adjustable |
| Measurement Range | Transmittance/Reflectance: 0-100% |
| Detector | 2048 Pixels, CMOS Imported from Japan |
| Single Acquisition Time | better than 1s |
| Wavelength Accuracy | <1nm |
| Wavelength Repeatability | 0.2nm |
| Display Accuracy | 0.01% |
| Instrument Repeatability | <1% |
| Dark Background Subtraction | Automatic Subtraction |
| Illumination Accessories | Dedicated halogen lamp source; output stability <0.1% over 8 hours; continuous use for 4000 hours |
| Translation stage - Load-bearing surface dimensions | 200(W)×200(D)mm |
| Translation stage - Load capacity | 3 kg |
| Translation stage - Working range [(XY)] | (XY) ±40mm |
| Translation stage - Working range [(Z)] | (Z)125mm |
| Operating environment | Horizontal, Vibration-Free Location, Room Temperature and Atmospheric Pressure |
| Minimum Measurable Sample Size | >1mm |
| Maximum Measurable Sample Size | Transmission/Reflection: Any Size |