High and Low Temperature Test Chamber Repair (YCT-150)
Guangdong Yuanyao Instrument Equipment Co., Ltd. main repair categories for high and low temperature test chambers: 1 Control system (uncontrolled temperature, uncontrolled humidity, controller temperature and humidity calibration, control system not working properly, sensor failure, electronic door lock replacement and repair, etc.) 2 Refrigeration system (refrigerant leakage R404A, R502, F13, R23, R134A, R508B, ISC89) various refrigerants are in stock, pipe rupture welding, expansion valve repair, filter replacement, compressor lubricating oil filling, condenser cleaning, needle valve installation, etc.) 3 Heating system (heater repair, thyristor replacement, solid state relay, contactor, time relay, intermediate relay, heating high-temperature wire replacement, adding heaters, etc.) 4 Mechanical system (repair of circulation motor, fan blades, improvement of circulation air duct, modification of unreasonable chamber structure, installation of lead holes, etc.) 5 Humidity system (repair of humidification filter, repair and replacement of humidity sensor, repair of humidification water supply pipe, repair of drainage pipe, repair of humidification and dehumidification system, wet bulb gauze replacement, etc.)
Overview
Specifications
| Parameter | Value |
|---|---|
| Inner Chamber Dimensions W×H×D | 50 cm × 60 cm × 50 cm |
| Outer box size W×H×D | 70 cm × 174 cm × 130 cm |
| Temperature Range [Other temperatures can be customized] | -70 ℃, -60 ℃, -40 ℃, -20 ℃, 0 ℃~150 ℃, other temperatures can be customized |
| Humidity Range [Low humidity 10%RH~98%RH or 5%RH~98%RH customizable] | 20 %RH~98 %RH (low humidity 10 %RH~98 %RH or 5 %RH~98 %RH customizable) |
| Temperature and Humidity Fluctuation | ±0.3 ℃;±0.5 %RH |
| Temperature and Humidity Uniformity [No load, 30min after stabilization] | ±2 ℃;±3 %RH (No load, 30 min after stabilization) ±2 ℃;±3 %RH |
| Resolution Accuracy | 0.01 ℃;0.1 %RH |
| Heating and Cooling Time | Heating: average 3 degrees per minute; Cooling: average 1 degree per minute |
| Outer Chamber Material | Cold-rolled steel plate + baked paint |
| Inner Chamber Material | SUS#304 Stainless Steel Plate |
| Insulation Material | PU |
| Circulation System | Centrifugal fan air circulation system |
| Heating System | SUS# stainless steel high-speed heater |
| Humidification System | Electric Heating Steam Humidification |
| Dehumidification System | ADP Critical Dew Point Cooling/Dehumidification Method ADP |
| Refrigeration System | Compressor + Finned Evaporator + Air-Cooled (water-cooled) Condenser |
| Control System | Touch LCD Screen + SSR + PID |
| Protection Devices | Overheat Protection Circuit Breaker, Humidification System Overheat Protection, Compressor Overload Protection, Control System Overload Protection, Overload Indicator Light, Phase Sequence Protection, Water Shortage Protection, High/Low Pressure Protection, Over-Temperature Protection, Water Supply Delay Protection, Fan Overcurrent Protection |
| Power Supply [AC;1Ψ;3Ψ;60/50Hz] | AC 1Ψ 220 V; 3Ψ 380 V 60/50 Hz |
| Accessories | Vacuum Glass Observation Window, Power-On Test Port (50 mm), Control Status Indicator Light, Window Light, Shelves (2 pcs, height adjustable) |