VarioCAM HD head (980)
The VarioCAM HD head series of high-definition long-wave infrared thermal imagers delivers excellent imaging quality and accurate temperature measurement. It adopts a 1024x768-pixel microbolometer focal plane array detector, with a full frame rate of 30Hz and a frame rate of up to 240Hz in sub-frame imaging mode. Through the built-in third-generation MicroScan opto-mechanical micro-scanning displacement high-resolution imaging component, it can generate 2048x1536-pixel ultra-high-resolution infrared thermal images. The entire series uses high-quality large-aperture infrared lenses, including microscopic, close-focus close-up, wide-angle, standard and telephoto, with automatic recognition. It comes with the highly acclaimed IRBIS professional infrared thermal image analysis and management software, integrating functions such as online control of the thermal imager, infrared thermal image data acquisition, real-time and offline infrared thermal image analysis and evaluation, image browsing and management, and report generation.
Overview
Specifications
| Parameter | Value |
|---|---|
| Detector Type | High-definition uncooled microbolometer focal plane detector |
| Detector specifications [30Hz] | 1024x768 pixels@30 Hz |
| Subwindow mode [60Hz] | 640×480 pixels @60 Hz |
| Subwindow mode [120Hz] | 384×288 pixels @120 Hz |
| Subwindow mode [240Hz] | 1024×96 pixels @240 Hz |
| MicroScan optical-mechanical micro-scanning imaging [2Hz] | 2048x1536 pixel thermal image, capable of continuous operation, 2 Hz |
| Spectral Range | 7.5~14 um |
| Thermal sensitivity (NETD) [30℃] | 20 mK@30 ℃ |
| Digital Zoom | Maximum 32x continuous zoom |
| Dynamic Range | 16 bit |
| Temperature Measurement Range | (-40~+1200)℃ |
| Temperature measurement range extension | Expandable up to +2000 ℃ |
| Range switching method | Automatic or manual switching |
| Temperature measurement accuracy [at 0~100℃] | ±1.0 ℃ |
| Temperature measurement accuracy [at <0 or >100℃] | ±1 % |
| Measurement Mode | Movable point or area automatic tracking of maximum/minimum temperature, line temperature profile, histogram, △T, temperature difference between two points (time, position) |
| Temperature alarm | Settable upper and lower temperature alarm values provide automatic audible or color alarm alerts |
| Color isotherms | Settable 10 high-contrast color isotherms |
| Emissivity Correction | Manual setting: 0.1~1.0, 0.01/step; or use preset material table |
| Atmospheric transmittance correction | Automatic, based on input distance, atmospheric temperature and relative humidity |
| Optical transmittance correction | Automatic, based on the thermal imager's internal sensor signals |
| Reflected ambient temperature correction | Automatic, based on input reflected temperature |
| External optics/window correction | Automatic, based on input optical/window transmittance and temperature |
| Focus Method | Built-in precise stepper focusing motor supports automatic and manual focus |
| Close-up function [When using standard lens] | When using the standard lens, a 10 cm close-range imaging function is optional |
| Infrared thermal image storage | Single frame or continuous, via GigE Vision to the computer hard disk |
| Image transmission interface | GigE Vision, DVI-D, C-Video |
| Thermal imager control interface | GigE Vision, optional RS232, Trigger analog output, digital I/O |
| Software | IRBIS 3 series infrared thermal image management, thermal image analysis, online control, and real-time measurement and thermal image acquisition |
| Power Supply Method | DC power adapter 15 VDC, PoE power supply (optional) |
| Operating Temperature | -25~+50 ℃ |
| Storage Temperature | -40 ℃~+70 ℃ |
| Relative humidity [Non-condensing] | 10 %~95 % non-condensing |
| Shock resistance/vibration resistance [During operation] | 2G, IEC 68-2-29 / 25G, IEC 68-2-6 Note: during operation |
| Package | IP54, IEC 529; optional IP67 |
| Body dimensions | 190 mm × 90 mm × 94 mm |
| Weight | Approx. 1.15 kg |
| Infrared lens - minimum focal distance [30mm standard] | 0.3 m |
| Infrared lens - field of view [30mm standard] | 32×24 |
| Infrared lens - spatial resolution [30mm standard] | 0.57 mrad. |
| Infrared lens - minimum focal distance [15mm wide-angle] | 0.2 m |
| Infrared lens - field of view [15mm wide-angle] | 60x47 |
| Infrared lens - Spatial resolution [15mm wide-angle] | 1.1 mrad. |
| Infrared lens - Minimum focal length [7.5mm ultra-wide angle] | 0.1 m |
| Infrared lens - Field of view [7.5mm ultra-wide angle] | 98x82 |
| Infrared lens - Spatial resolution [7.5mm ultra-wide angle] | 2.3 mrad. |
| Infrared lens - Minimum focal length [60mm telephoto] | 2.0 m |
| Infrared lens - Field of view [60mm telephoto] | 16×12 |
| Infrared lens - Spatial resolution [60mm telephoto] | 0.28 mrad. |
| Infrared lens - Minimum focal length [120mm telephoto] | 4.0 m |
| Infrared lens - Field of view [120mm telephoto] | 8.3x6.2 |
| Infrared lens - Spatial resolution [120mm telephoto] | 0.14 mrad. |
| Infrared lens - Minimum focal length [0.2x/30mm close-up] | (75 .135)mm |
| Infrared lens - Field of view [0.2x/30mm close-up] | 54 mm × 40 mm |
| Infrared lens - Spatial resolution [0.2x/30mm close-up] | 53 μm |
| Infrared lens - Minimum focal length [0.5x/30mm close-up] | (30.45)mm |
| Infrared lens - Field of view [0.5x/30mm close-up] | 30 mm × 23 mm |
| Infrared lens - Spatial resolution [0.5x/30mm close-up] | 29 μm |
| Infrared lens - Minimum focal length [0.5×/60mm close-up] | (75 .100)mm |
| Infrared lens - Field of view [0.5×/60mm close-up] | 30 mm × 23 mm |
| Infrared lens - Spatial resolution [0.5×/60mm close-up] | 29 μm |
| Infrared lens - Minimum focal length [1.0× microscopic] | 40 mm |
| Infrared lens - Spatial resolution [1.0× microscopic] | 17 μm |
Applications