USB-DT UV-Visible combined light source
USB-DT Deuterium Light Source Tungsten Halogen Lamp; Our most powerful UV-Visible combination light source; The USB-DT Deuterium Light Source Tungsten Halogen Lamp is a compact light source, only the size of a deck of cards, that provides stable broad-band output in the range of 200~2000nm. USB-DT is our most powerful UV-Visible light source developed, allowing users to control its functions via software so that it can satisfy measurement requirements in various ways.; Software control; Adjust the brightness of the tungsten filament; Activate the internal shutter to block the optical path; Independently control the on/off shutter of each light source; Utilize the low-power shutdown mode; Save settings of experimental conditions; UV-Visible combination light source used together with the USB4000 fiber optic spectrometer; The USB-DT light source can be configured in different ways and can be connected above the USB4000 line spectrometer via the USB-ADP-DT2 connector, in the form shown in the picture on the right. The USB-ADP-DT2 connector must be purchased separately. Since the USB-DT light source is connected to the USB2000 spectrometer in a stacked manner, it cannot be like a directly attached light source that requires no fiber connection, so a fiber optic and a 5V transformer (included) are also required.; Innovative Deuterium Light Source Tungsten Halogen Lamp; Spectral output diagram of the USB-DT light source; Product Specifications; Dimensions; Weight; 260 g; Power Consumption; 1.5A, 5V (DC); Spectral Range; Warm-up Time for Stable Output; 15min; Bulb Life; Deuterium lamp 800h; Tungsten 2000h; Connector; Power Output; Refer to the spectral output diagram above; Stability; 0.5% peak-to-peak (after warm-up); Ordering Information; Model; USB-DT; Deuterium Light Source Tungsten Lamp; USB-DT-B Bulb; Replacement bulb for the USB-DT light source; USB-ADP-DT2; Adapter for connecting and synchronizing the USB-DT with the USB2000; UV-Visible combination light source used together with the USB4000 fiber optic spectrometer The USB-DT light source can be configured in different ways and can be connected above the USB4000 line spectrometer via the USB-ADP-DT2 connector, in the form shown in the picture on the right. The USB-ADP-DT2 connector must be purchased separately. Since the USB-DT light source is connected to the USB2000 spectrometer in a stacked manner, it cannot be like a directly attached light source that requires no fiber connection, so a fiber optic and a 5V transformer (included) are also required.
Overview
Specifications
| Parameter | Value |
|---|---|
| Dimensions | 81 mm × 90 mm × 37 mm |
| Weight | 260 g |
| Power consumption | 1.5 A, 5 V (DC) |
| Spectral Range | 200-2000 nm |
| Warm-up time for stable output | 15 min |
| Bulb lifetime | Deuterium lamp 800 h; tungsten 2000 h |
| Connector | SMA 905 |
| Power output | Refer to the spectral output figure above |
| Stability | 0.5 % peak-to-peak (after warm-up) |
Datasheet
Please provide your email to download the datasheet.
Invalid email format. Please try again.
Supplier Information
Loading...
Name
Phone
Organization
Use Case

Database Platform