Current Category:
- 3D Scanner
- Beam Profilers
- Conventional Microscopes
- Displacement Gages
- Sensors
- Fiber Inspection Tools
- Fiber Test & Measurement
- Gas Analysis
- Interferometers
- Laser Scanning and Ranging
- LiDAR
- Material Analysis and Forensics
- Measurement Devices
- Metrology Accessories
- Microscope Accessories
- Microscopes
- Optical Cells
- Optical Inspection
- Optical Metrology
- Optical Power Meters
- Optical Spectrum Analyzers
- Optical Surface Profiler
- Optical Wavelength Meters
- Scanners and Rangefinders
- Size Measurement
- Spectrometers
- Terahertz
- Thermal Solutions
- Waveform Generators and Analyzers
- Other
- Probe Station
- Probe Station Accessories
Country:
More
Photonics Source provides 639 products. Download datasheets, request quotes, and compare function, price, and availability.
-
Precision Waveform Measurement Essentials
Maximum Input Voltage: 1000V DC+ACpeak Frequency Range: 100MHz Attenuation Ratio: 10:1 Input Capacitance: 57.5pF Total Length: 2.5m -
Precision waveform measurement essentials
Maximum Input Voltage: 900MHz Frequency Range: 10V DC+ACpeak Attenuation Ratio: 10:1 Input Capacitance: 4500/9500pF Total Length: 1.1m -
Precision waveform measurement essentials
Maximum Input Voltage: 600V DC+ACpeak Frequency Range: 200MHz Attenuation Ratio: 10:1 Input Capacitance: 13.5pF Total Length: 1.5m -
Precision waveform measurement essentials
Maximum Input Voltage: 900MHz Frequency Range: 10V DC+ACpeak Attenuation Ratio: 10:1 Input Capacitance: 4500/90.25pF Total Length: 1.1m -
Precision Waveform Measurement Probes and Accessories
Maximum Input Voltage 701938: 600V(DC+ACpeak) Maximum Input Voltage 701939: 600V(DC+ACpeak) Maximum Input Voltage 701940: 1000V(DC+ACpeak) Maximum Input Voltage 701946: 400V(DC+ACpeak) Maximum Input Voltage 701943: 1000V(DC+ACpeak) -
Precision waveform measurement essentials
Maximum Input Voltage: 600V(DC+ACpeak) Frequency Range: 200MHz Attenuation Ratio: 10:1 Input Capacitance: 13.5pF Total Length: 1.5m -
Precision waveform measurement essentials
Frequency Bandwidth: 10MHz-5000MHz Maximum Input Voltage: 20V-7000V Attenuation Ratio: 10:1-1000:1 Input Impedance: 10MΩ/approx. 22pF Maximum Input Current: 0.5A-500A -
Precision Waveform Measurement Accessories
Frequency Bandwidth: 10MHz-5GHz Maximum Input Voltage: 20V-7000V Attenuation Ratio: 10:1-1000:1 Input Impedance: 10MΩ/10pF-100kΩ/3pF Maximum Input Current: 0.5A-500A -
SMARTDAC+ GM Data Acquisition System
Maximum System Channels: 420 Storage Capacity: 1.2GB Operating Temperature Range: -20°C to 60°C Supported Network Protocols: Modbus, EtherNet/IP, SLMP, OPC-UA Measurement Accuracy: ±0.05% -
VZ20X Analog Sensing Unit
Number of inputs: 8 channels Input types: DC voltage, unified signal, 4-wire resistor, thermocouple, and 3-wire/4-wire RTD Data acquisition interval: 1ms (fastest, 8 channels simultaneous measurement) Measurement synchronization accuracy: Within ±100μs (between input channels, between units) Measurement Accuracy: 0.025% of FS (with DC voltage, and power supply frequency noise removal filter enabled) -
EY200 Digital Earth Tester
Measuring Range and Accuracy: Earth voltage: 0 to 199.9V ±(1.0%rdg+4dgt), Earth resistance: 20Ω: 0 to 19.99Ω ±(2.0%rdg+0.1Ω), 200Ω: 0 to 199.9Ω ±(2.0%rdg+3dgt), 2000Ω: 0 to 1999Ω ±(Auxiliary earth resistance 100Ω±5%) EMC Standards: EN61326-1 Class B Table 1, EN61326-2-2 Safety Standards: EN61010-1, EN IEC61010-2-030, Measurement category III (CAT III) 300V, Pollution degree 2 Environmental standards: EU RoHS Directive compliant Measuring Method: Earth voltage measurement: Mean value, Earth resistance measurement: Constant current inverter, Measuring current: Approx. AC3mA (at 20Ω range), Frequency: Approx. 820Hz -
GA10 Data Logging Software
Maximum Connected Devices: 100台 High-Speed Acquisition Rate: 100ms或更低 Maximum Data Tags: 10000 complete plans标签 Operating System: Windows 8.1, Windows 10, Windows Server 2008 R2, Windows Server 2012, Windows Server 2012 R2, Windows Server 2016, Windows Server 2019 CPU: Intel Core2 Duo E6300或更高 -
CT Series Current Sensors and Probes
Rated Current (DC): 0 to 60A, 0 to 200A, 0 to 1000A, 0 to 2000A Rated Current (AC): 60Apeak, 200Apeak, 1000Apeak, 2000Apeak Current Transformation Ratio: 600:1, 1000:1, 1500:1, 2000:1 Accuracy: DC ±0.05% of rdg + 30μA (CT60), DC ±0.05% of rdg + 30μA (CT200), DC ±0.04% of rdg + 30μA (CT1000, CT1000A), DC ±0.05% of rdg + 30μA (CT2000A) Measurement Range: DC to 800kHz (CT60), DC to 500kHz (CT200), DC to 300kHz (CT1000, CT1000A), DC to 40kHz (CT2000A) -
DM7560 Digital Multimeter
Measurement Method: Delta-sigma A/D converter Measurement mode: AUTO/SINGLE (selectable) Sampling Rate: Up to 30kS/s Display Resolution: 6½ digits Display: 4.3-inch TFT active matrix LCD, 480×272 dots, 16-bit color -
DM7560 Digital Multimeter
Measurement Method: Delta-sigma A/D converter Measurement mode: AUTO/SINGLE selectable Sampling Rate: Up to 30kS/s Display Size: 4.3 inch Display Resolution: 480×272 dots -
AQ2200 Series
Insertion Loss (dB) 1x2: ≤4.0 Insertion Loss (dB) 1x4: ≤7.4 Uniformity (dB) 1x2: ≤0.6 Uniformity (dB) 1x4: ≤1.0 Light Source Wavelength Range: 1310nm, 1550nm, 1625nm -
701934 Power Supply
Input Voltage: AC100-240V (50/60Hz) Output Voltage: ±12V, ±5V Output Current: ±12V: 2.5A, ±5V: 2.5A Dimensions: 598mm×111mm×200mm Weight: Approx. 12kg -
CA71 Portable Process Calibrator
Voltage Measurement Range: 0-1100V Current Measurement Range: 0-24mA Resistance Measurement Range: 0-3200Ω Thermocouple Measurement Range: -200°C to 1800°C Frequency Measurement Range: 0.01Hz to 110kHz -
Precision Waveform Measurement Probes
Maximum Input Voltage: 600VDC+ACpeak Frequency Range: 200MHz Attenuation Ratio: 10:1 Input Resistance/Capacitance: 10MΩ/13.5pF Total Length: 1.5m -
Precision waveform measurement essentials
Maximum Input Voltage: 600VDC+ACpeak Frequency Range: 200MHz Attenuation Ratio: 10:1 Input Resistance/Capacitance: 10MΩ/13.5pF Total Length: 1.5m