Polarization-Maintaining Fiber
Panda polarization-maintaining fiber is made by MCVD (modified chemical vapor deposition), offering excellent polarization retention, precise refractive-index profiles, symmetric cross-sectional geometry, longitudinal uniformity and optical performance. Dual UV-cured coatings provide environmental stability. Low attenuation and excellent birefringence suit fiber gyros and other polarization-related devices. The straight-line PM fiber has an independently developed structure combining advantages of bow-tie and elliptical-jacket fibers. Its distinctive small stress region, only 1/3–1/4 the Panda area, gives equal or better polarization retention while greatly improving temperature behavior, bend resistance and strength. It is successfully used in navigation, positioning and attitude control on maritime, land, airborne and space platforms.
Overview
Specifications
| Parameter | Value |
|---|---|
| Attenuation [PANDA Type; Polarization-Maintaining Fiber for Gyroscopes; Product Type: 125/245] | ≤1.0 dB/km |
| Polarization Crosstalk [PANDA Type; Polarization-Maintaining Fiber for Gyroscopes; Product Type: 125/245] | ≤-30 dB/km |
| Cladding Diameter [PANDA Type; Polarization-Maintaining Fiber for Gyroscopes; Product Type: 125/245] | 125.0±1.0 |
| Coating Diameter [PANDA Type; Polarization-Maintaining Fiber for Gyroscopes; Product Type: 125/245] | 245.0±3.0 |
| Core-Cladding Concentricity [PANDA Type; Polarization-Maintaining Fiber for Gyroscopes; Product Type: 125/245] | ≤1.0 μm |
| Cladding Non-Circularity [PANDA Type; Polarization-Maintaining Fiber for Gyroscopes; Product Type: 125/245] | ≤1 % |
| Operating Temperature Range [PANDA Type; Polarization-Maintaining Fiber for Gyroscopes; Product Type: 125/245] | -45~+85 °C |
| Proof-Test Level [PANDA Type; Polarization-Maintaining Fiber for Gyroscopes; Product Type: 125/245] | 100 kpsi |
| Coating Noncircularity [PANDA Type; Polarization-Maintaining Fiber for Gyroscopes; Product Type: 125/245] | ≤5 % |
| Operating Wavelength [Panda Type; Polarization-Maintaining Fiber for Gyroscopes; Product Type: 125/245; Operating Wavelength: 1310nm] | 1310 nm |
| Cutoff Wavelength [Panda Type; Polarization-Maintaining Fiber for Gyroscopes; Product Type: 125/245; Operating Wavelength: 1310nm] | 1100-1290 nm |
| Mode Field Diameter [Panda Type; Polarization-Maintaining Fiber for Gyroscopes; Product Type: 125/245; Operating Wavelength: 1310nm] | 6.0±0.5 |
| Beat Length [Panda Type; Polarization-Maintaining Fiber for Gyroscopes; Product Type: 125/245; Operating Wavelength: 1310nm] | ≤3.0 mm |
| Operating Wavelength [Panda Type; Polarization-Maintaining Fiber for Gyroscopes; Product Type: 125/245; Operating Wavelength: 1550nm] | 1550 nm |
| Cutoff Wavelength [Panda Type; Polarization-Maintaining Fiber for Gyroscopes; Product Type: 125/245; Operating Wavelength: 1550nm] | 1290-1520 nm |
| Mode Field Diameter [Panda Type; Polarization-Maintaining Fiber for Gyroscopes; Product Type: 125/245; Operating Wavelength: 1550nm] | 6.5±0.5 |
| Beat Length [Panda Type; Polarization-Maintaining Fiber for Gyroscopes; Product Type: 125/245; Operating Wavelength: 1550nm] | ≤3.5 mm |
| Attenuation [PANDA Type; Polarization-Maintaining Fiber for Gyroscopes; Product Type: 80/165(135*)] | ≤1.0 dB/km |
| Polarization Crosstalk [PANDA Type; Polarization-Maintaining Fiber for Gyroscopes; Product Type: 80/165(135*)] | ≤-30 dB/km |
| Cladding Diameter [PANDA Type; Polarization-Maintaining Fiber for Gyroscopes; Product Type: 80/165(135*)] | 80.0±1.0 |
| Coating Diameter [PANDA Type; Polarization-Maintaining Fiber for Gyroscopes; Product Type: 80/165(135*)] | 165.0±3.0/135.0±3.0 |
| Core-Cladding Concentricity [PANDA Type; Polarization-Maintaining Fiber for Gyroscopes; Product Type: 80/165(135*)] | ≤1.0 μm |
| Cladding Non-Circularity [PANDA Type; Polarization-Maintaining Fiber for Gyroscopes; Product Type: 80/165(135*)] | ≤1 % |
| Operating Temperature Range [PANDA Type; Polarization-Maintaining Fiber for Gyroscopes; Product Type: 80/165(135*)] | -45~+85 °C |
| Proof-Test Level [PANDA Type; Polarization-Maintaining Fiber for Gyroscopes; Product Type: 80/165(135*)] | 100 kpsi |
| Coating Noncircularity [PANDA Type; Polarization-Maintaining Fiber for Gyroscopes; Product Type: 80/165(135*)] | ≤5 % |
| Operating Wavelength [PANDA Type; Polarization-Maintaining Fiber for Gyroscopes; Product Type: 80/165(135*); Operating Wavelength: 1310nm] | 1310 nm |
| Cutoff Wavelength [PANDA Type; Polarization-Maintaining Fiber for Gyroscopes; Product Type: 80/165(135*); Operating Wavelength: 1310nm] | 1100-1290 nm |
| Mode Field Diameter [PANDA Type; Polarization-Maintaining Fiber for Gyroscopes; Product Type: 80/165(135*); Operating Wavelength: 1310nm] | 6.0±0.5 |
| Beat Length [PANDA Type; Polarization-Maintaining Fiber for Gyroscopes; Product Type: 80/165(135*); Operating Wavelength: 1310nm] | ≤3.0 mm |
| Operating Wavelength [PANDA Type; Polarization-Maintaining Fiber for Gyroscopes; Product Type: 80/165(135*); Operating Wavelength: 1550nm] | 1550 nm |
| Cutoff Wavelength [PANDA Type; Polarization-Maintaining Fiber for Gyroscopes; Product Type: 80/165(135*); Operating Wavelength: 1550nm] | 1290-1520 nm |
| Mode Field Diameter [PANDA Type; Polarization-Maintaining Fiber for Gyroscopes; Product Type: 80/165(135*); Operating Wavelength: 1550nm] | 6.5±0.5 |
| Beat Length [PANDA Type; Polarization-Maintaining Fiber for Gyroscopes; Product Type: 80/165(135*); Operating Wavelength: 1550nm] | ≤3.5 mm |
| Attenuation [PANDA Type; Polarization-Maintaining Fiber for Gyroscopes; Product Type: 60/100] | ≤1.0 dB/km |
| Polarization Crosstalk [PANDA Type; Polarization-Maintaining Fiber for Gyroscopes; Product Type: 60/100] | ≤-25 dB/km |
| Cladding Diameter [PANDA Type; Polarization-Maintaining Fiber for Gyroscopes; Product Type: 60/100] | 60.0±1.0 |
| Coating Diameter [PANDA Type; Polarization-Maintaining Fiber for Gyroscopes; Product Type: 60/100] | 100.0±3.0 |
| Core-Cladding Concentricity [PANDA Type; Polarization-Maintaining Fiber for Gyroscopes; Product Type: 60/100] | ≤1.0 μm |
| Cladding Non-Circularity [PANDA Type; Polarization-Maintaining Fiber for Gyroscopes; Product Type: 60/100] | ≤1 % |
| Operating Temperature Range [PANDA Type; Polarization-Maintaining Fiber for Gyroscopes; Product Type: 60/100] | -45~+85 °C |
| Proof-Test Level [PANDA Type; Polarization-Maintaining Fiber for Gyroscopes; Product Type: 60/100] | 100 kpsi |
| Coating Noncircularity [PANDA Type; Polarization-Maintaining Fiber for Gyroscopes; Product Type: 60/100] | ≤5 % |
| Operating Wavelength [Panda Type; Polarization-Maintaining Fiber for Gyroscopes; Product Type: 60/100; Operating Wavelength: 1310nm] | 1310 nm |
| Cutoff Wavelength [Panda Type; Polarization-Maintaining Fiber for Gyroscopes; Product Type: 60/100; Operating Wavelength: 1310nm] | 1100-1290 nm |
| Mode Field Diameter [Panda Type; Polarization-Maintaining Fiber for Gyroscopes; Product Type: 60/100; Operating Wavelength: 1310nm] | 6.0±0.5 |
| Beat Length [Panda Type; Polarization-Maintaining Fiber for Gyroscopes; Product Type: 60/100; Operating Wavelength: 1310nm] | ≤3.0 mm |
| Operating Wavelength [Panda Type; Polarization-Maintaining Fiber for Gyroscopes; Product Type: 60/100; Operating Wavelength: 1550nm] | 1550 nm |
| Cutoff Wavelength [Panda Type; Polarization-Maintaining Fiber for Gyroscopes; Product Type: 60/100; Operating Wavelength: 1550nm] | 1290-1520 nm |
| Mode Field Diameter [Panda Type; Polarization-Maintaining Fiber for Gyroscopes; Product Type: 60/100; Operating Wavelength: 1550nm] | 6.5±0.5 |
| Beat Length [Panda Type; Polarization-Maintaining Fiber for Gyroscopes; Product Type: 60/100; Operating Wavelength: 1550nm] | ≤3.5 mm |
| Attenuation [In-Line Type Polarization-Maintaining Fiber; Product Type: 125/245] | ≤1.0 dB/km |
| Polarization Crosstalk [In-Line Type Polarization-Maintaining Fiber; Product Type: 125/245] | ≤-30 dB/km |
| Cladding Diameter [In-Line Type Polarization-Maintaining Fiber; Product Type: 125/245] | 125.0±1.0 |
| Coating Diameter [In-Line Type Polarization-Maintaining Fiber; Product Type: 125/245] | 245.0±3.0 |
| Core-Cladding Concentricity [In-Line Type Polarization-Maintaining Fiber; Product Type: 125/245] | ≤1.0 μm |
| Cladding Non-Circularity [In-Line Type Polarization-Maintaining Fiber; Product Type: 125/245] | ≤1 % |
| Operating Temperature Range [In-Line Type Polarization-Maintaining Fiber; Product Type: 125/245] | -45~+85 °C |
| Proof-Test Level [In-Line Type Polarization-Maintaining Fiber; Product Type: 125/245] | 100 kpsi |
| Operating Wavelength [Straight-Type Polarization-Maintaining Fiber; Product Type: 125/245; Operating Wavelength: 1310nm] | 1310 nm |
| Cutoff Wavelength [Straight-Type Polarization-Maintaining Fiber; Product Type: 125/245; Operating Wavelength: 1310nm] | 1100-1290 nm |
| Mode Field Diameter [Straight-Type Polarization-Maintaining Fiber; Product Type: 125/245; Operating Wavelength: 1310nm] | 6.0±0.5 |
| Beat Length [Straight-Type Polarization-Maintaining Fiber; Product Type: 125/245; Operating Wavelength: 1310nm] | ≤3.0 mm |
| Operating Wavelength [Straight-Type Polarization-Maintaining Fiber; Product Type: 125/245; Operating Wavelength: 1550nm] | 1550 nm |
| Cutoff Wavelength [Straight-Type Polarization-Maintaining Fiber; Product Type: 125/245; Operating Wavelength: 1550nm] | 1290-1520 nm |
| Mode Field Diameter [Straight-Type Polarization-Maintaining Fiber; Product Type: 125/245; Operating Wavelength: 1550nm] | 6.5±0.5 |
| Beat Length [Straight-Type Polarization-Maintaining Fiber; Product Type: 125/245; Operating Wavelength: 1550nm] | ≤3.5 mm |
| Attenuation [In-Line Type Polarization-Maintaining Fiber; Product Type: 80/165(135*)] | ≤1.0 dB/km |
| Polarization Crosstalk [In-Line Type Polarization-Maintaining Fiber; Product Type: 80/165(135*)] | ≤-30 dB/km |
| Cladding Diameter [In-Line Type Polarization-Maintaining Fiber; Product Type: 80/165(135*)] | 80.0±1.0 |
| Coating Diameter [In-Line Type Polarization-Maintaining Fiber; Product Type: 80/165(135*)] | 165.0±3.0/135.0±3.0 |
| Core-Cladding Concentricity [In-Line Type Polarization-Maintaining Fiber; Product Type: 80/165(135*)] | ≤1.0 μm |
| Cladding Non-Circularity [In-Line Type Polarization-Maintaining Fiber; Product Type: 80/165(135*)] | ≤1 % |
| Operating Temperature Range [In-Line Type Polarization-Maintaining Fiber; Product Type: 80/165(135*)] | -45~+85 °C |
| Proof-Test Level [In-Line Type Polarization-Maintaining Fiber; Product Type: 80/165(135*)] | 100 kpsi |
| Operating Wavelength [In-Line Polarization-Maintaining Fiber; Product Type: 80/165(135*); Operating Wavelength: 1310nm] | 1310 nm |
| Cutoff Wavelength [In-Line Polarization-Maintaining Fiber; Product Type: 80/165(135*); Operating Wavelength: 1310nm] | 1100-1290 nm |
| Mode Field Diameter [In-Line Polarization-Maintaining Fiber; Product Type: 80/165(135*); Operating Wavelength: 1310nm] | 6.0±0.5 |
| Beat Length [In-Line Polarization-Maintaining Fiber; Product Type: 80/165(135*); Operating Wavelength: 1310nm] | ≤3.0 mm |
| Operating Wavelength [In-Line Polarization-Maintaining Fiber; Product Type: 80/165(135*); Operating Wavelength: 1550nm] | 1550 nm |
| Cutoff Wavelength [In-Line Polarization-Maintaining Fiber; Product Type: 80/165(135*); Operating Wavelength: 1550nm] | 1290-1520 nm |
| Mode Field Diameter [In-Line Polarization-Maintaining Fiber; Product Type: 80/165(135*); Operating Wavelength: 1550nm] | 6.5±0.5 |
| Beat Length [In-Line Polarization-Maintaining Fiber; Product Type: 80/165(135*); Operating Wavelength: 1550nm] | ≤3.5 mm |
| Attenuation [In-Line Type Polarization-Maintaining Fiber; Product Type: 60/100] | ≤1.0 dB/km |
| Polarization Crosstalk [In-Line Type Polarization-Maintaining Fiber; Product Type: 60/100] | ≤-25 dB/km |
| Cladding Diameter [In-Line Type Polarization-Maintaining Fiber; Product Type: 60/100] | 60.0±1.0 |
| Coating Diameter [In-Line Type Polarization-Maintaining Fiber; Product Type: 60/100] | 100.0±3.0 |
| Core-Cladding Concentricity [In-Line Type Polarization-Maintaining Fiber; Product Type: 60/100] | ≤1.0 μm |
| Cladding Non-Circularity [In-Line Type Polarization-Maintaining Fiber; Product Type: 60/100] | ≤1 % |
| Operating Temperature Range [In-Line Type Polarization-Maintaining Fiber; Product Type: 60/100] | -45~+85 °C |
| Proof-Test Level [In-Line Type Polarization-Maintaining Fiber; Product Type: 60/100] | 100 kpsi |
| Operating Wavelength [Straight-Type Polarization-Maintaining Fiber; Product Type: 60/100; Operating Wavelength: 1310nm] | 1310 nm |
| Cutoff Wavelength [Straight-Type Polarization-Maintaining Fiber; Product Type: 60/100; Operating Wavelength: 1310nm] | 1100-1290 nm |
| Mode Field Diameter [Straight-Type Polarization-Maintaining Fiber; Product Type: 60/100; Operating Wavelength: 1310nm] | 6.0±0.5 |
| Beat Length [Straight-Type Polarization-Maintaining Fiber; Product Type: 60/100; Operating Wavelength: 1310nm] | ≤3.0 mm |
| Operating Wavelength [Straight-Type Polarization-Maintaining Fiber; Product Type: 60/100; Operating Wavelength: 1550nm] | 1550 nm |
| Cutoff Wavelength [Straight-Type Polarization-Maintaining Fiber; Product Type: 60/100; Operating Wavelength: 1550nm] | 1290-1520 nm |
| Mode Field Diameter [Straight-Type Polarization-Maintaining Fiber; Product Type: 60/100; Operating Wavelength: 1550nm] | 6.5±0.5 |
| Beat Length [Straight-Type Polarization-Maintaining Fiber; Product Type: 60/100; Operating Wavelength: 1550nm] | ≤3.5 mm |
| Attenuation [Polarization-Maintaining Fiber for Waveguides; Product Type: PMF125/245YP] | ≤1.0 dB/km |
| Polarization Crosstalk [Polarization-Maintaining Fiber for Waveguides; Product Type: PMF125/245YP] | ≤-30 dB/km |
| Cladding Diameter [Polarization-Maintaining Fiber for Waveguides; Product Type: PMF125/245YP] | 125.0±1.0 |
| Coating Diameter [Polarization-Maintaining Fiber for Waveguides; Product Type: PMF125/245YP] | 245.0±3.0 |
| Core-Cladding Concentricity [Polarization-Maintaining Fiber for Waveguides; Product Type: PMF125/245YP] | ≤1.0 μm |
| Cladding Non-Circularity [Polarization-Maintaining Fiber for Waveguides; Product Type: PMF125/245YP] | ≤1 % |
| Operating Temperature Range [Polarization-Maintaining Fiber for Waveguides; Product Type: PMF125/245YP] | -45~+85 °C |
| Proof-Test Level [Polarization-Maintaining Fiber for Waveguides; Product Type: PMF125/245YP] | 100 kpsi |
| Coating Noncircularity [Polarization-Maintaining Fiber for Waveguides; Product Type: PMF125/245YP] | ≤5 % |
| Operating Wavelength [Polarization-Maintaining Fiber for Waveguides; Product Type: PMF125/245YP; Operating Wavelength: 1310nm] | 1310 nm |
| Cutoff Wavelength [Polarization-Maintaining Fiber for Waveguides; Product Type: PMF125/245YP; Operating Wavelength: 1310nm] | 1100-1290 nm |
| Mode Field Diameter [Polarization-Maintaining Fiber for Waveguides; Product Type: PMF125/245YP; Operating Wavelength: 1310nm] | 6.0±0.5 |
| Beat Length [Polarization-Maintaining Fiber for Waveguides; Product Type: PMF125/245YP; Operating Wavelength: 1310nm] | 2.5~3.5 mm |
| Operating Wavelength [Polarization-Maintaining Fiber for Waveguides; Product Type: PMF125/245YP; Operating Wavelength: 1550nm] | 1550 nm |
| Cutoff Wavelength [Polarization-Maintaining Fiber for Waveguides; Product Type: PMF125/245YP; Operating Wavelength: 1550nm] | 1290-1520 nm |
| Mode Field Diameter [Polarization-Maintaining Fiber for Waveguides; Product Type: PMF125/245YP; Operating Wavelength: 1550nm] | 6.5±0.5 |
| Beat Length [Polarization-Maintaining Fiber for Waveguides; Product Type: PMF125/245YP; Operating Wavelength: 1550nm] | 3.0~4.5 mm |
| Attenuation [Polarization-Maintaining Fiber for Waveguides; Product Type: PMF80/165] | ≤1.0 dB/km |
| Polarization Crosstalk [Polarization-Maintaining Fiber for Waveguides; Product Type: PMF80/165] | ≤-30 dB/km |
| Cladding Diameter [Polarization-Maintaining Fiber for Waveguides; Product Type: PMF80/165] | 80.0±1.0 |
| Coating Diameter [Polarization-Maintaining Fiber for Waveguides; Product Type: PMF80/165] | 165.0±3.0 |
| Core-Cladding Concentricity [Polarization-Maintaining Fiber for Waveguides; Product Type: PMF80/165] | ≤1.0 μm |
| Cladding Non-Circularity [Polarization-Maintaining Fiber for Waveguides; Product Type: PMF80/165] | ≤1 % |
| Operating Temperature Range [Polarization-Maintaining Fiber for Waveguides; Product Type: PMF80/165] | -45~+85 °C |
| Proof-Test Level [Polarization-Maintaining Fiber for Waveguides; Product Type: PMF80/165] | 100 kpsi |
| Coating Noncircularity [Polarization-Maintaining Fiber for Waveguides; Product Type: PMF80/165] | ≤5 % |
| Operating Wavelength [Polarization-Maintaining Fiber for Waveguides; Product Type: PMF80/165; Operating Wavelength: 1310nm] | 1310 nm |
| Cutoff Wavelength [Polarization-Maintaining Fiber for Waveguides; Product Type: PMF80/165; Operating Wavelength: 1310nm] | 1100-1290 nm |
| Mode Field Diameter [Polarization-Maintaining Fiber for Waveguides; Product Type: PMF80/165; Operating Wavelength: 1310nm] | 6.0±0.5 |
| Beat Length [Polarization-Maintaining Fiber for Waveguides; Product Type: PMF80/165; Operating Wavelength: 1310nm] | 2.5~3.5 mm |
| Operating Wavelength [Polarization-Maintaining Fiber for Waveguides; Product Type: PMF80/165; Operating Wavelength: 1550nm] | 1550 nm |
| Cutoff Wavelength [Polarization-Maintaining Fiber for Waveguides; Product Type: PMF80/165; Operating Wavelength: 1550nm] | 1290-1520 nm |
| Mode Field Diameter [Polarization-Maintaining Fiber for Waveguides; Product Type: PMF80/165; Operating Wavelength: 1550nm] | 6.5±0.5 |
| Beat Length [Polarization-Maintaining Fiber for Waveguides; Product Type: PMF80/165; Operating Wavelength: 1550nm] | 3.0~4.5 mm |
| Operating Wavelength [Polarization-Maintaining Fiber for Components; Product Type: PM980-125/245DP] | 980 nm |
| Cutoff Wavelength [Polarization-Maintaining Fiber for Components; Product Type: PM980-125/245DP] | 800-970 nm |
| Mode Field Diameter [Polarization-Maintaining Fiber for Components; Product Type: PM980-125/245DP] | 6.5±0.5 |
| Beat Length [Polarization-Maintaining Fiber for Components; Product Type: PM980-125/245DP] | ≤3.0 mm |
| Attenuation [Polarization-Maintaining Fiber for Components; Product Type: PM980-125/245DP] | ≤2.5 dB/km |
| Polarization Crosstalk [Polarization-Maintaining Fiber for Components; Product Type: PM980-125/245DP] | ≤-40 dB/4m |
| Polarization Crosstalk [Polarization-Maintaining Fiber for Components; Product Type: PM980-125/245DP] | ≤-30 dB/100m |
| Cladding Diameter [Polarization-Maintaining Fiber for Components; Product Type: PM980-125/245DP] | 125.0±1.0 |
| Coating Diameter [Polarization-Maintaining Fiber for Components; Product Type: PM980-125/245DP] | 245.0±3.0 |
| Core-Cladding Concentricity [Polarization-Maintaining Fiber for Components; Product Type: PM980-125/245DP] | ≤0.5 μm |
| Cladding Non-Circularity [Polarization-Maintaining Fiber for Components; Product Type: PM980-125/245DP] | ≤1 % |
| Coating Noncircularity [Polarization-Maintaining Fiber for Components; Product Type: PM980-125/245DP] | ≤5 % |
| Operating Temperature Range [Polarization-Maintaining Fiber for Components; Product Type: PM980-125/245DP] | -45~+85 °C |
| Proof-Test Level [Polarization-Maintaining Fiber for Components; Product Type: PM980-125/245DP] | 100 kpsi |
| Operating Wavelength [Polarization-Maintaining Fiber for Components; Product Type: PMF13-125/245DP] | 1310 nm |
| Cutoff Wavelength [Polarization-Maintaining Fiber for Components; Product Type: PMF13-125/245DP] | 1100-1290 nm |
| Mode Field Diameter [Polarization-Maintaining Fiber for Components; Product Type: PMF13-125/245DP] | 9.0±0.5 |
| Beat Length [Polarization-Maintaining Fiber for Components; Product Type: PMF13-125/245DP] | ≤4.0 mm |
| Attenuation [Polarization-Maintaining Fiber for Components; Product Type: PMF13-125/245DP] | ≤0.6 dB/km |
| Polarization Crosstalk [Polarization-Maintaining Fiber for Components; Product Type: PMF13-125/245DP] | ≤-40 dB/4m |
| Polarization Crosstalk [Polarization-Maintaining Fiber for Components; Product Type: PMF13-125/245DP] | ≤-30 dB/100m |
| Cladding Diameter [Polarization-Maintaining Fiber for Components; Product Type: PMF13-125/245DP] | 125.0±1.0 |
| Coating Diameter [Polarization-Maintaining Fiber for Components; Product Type: PMF13-125/245DP] | 245.0±3.0 |
| Core-Cladding Concentricity [Polarization-Maintaining Fiber for Components; Product Type: PMF13-125/245DP] | ≤1.0 μm |
| Cladding Non-Circularity [Polarization-Maintaining Fiber for Components; Product Type: PMF13-125/245DP] | ≤1 % |
| Coating Noncircularity [Polarization-Maintaining Fiber for Components; Product Type: PMF13-125/245DP] | ≤5 % |
| Operating Temperature Range [Polarization-Maintaining Fiber for Components; Product Type: PMF13-125/245DP] | -45~+85 °C |
| Proof-Test Level [Polarization-Maintaining Fiber for Components; Product Type: PMF13-125/245DP] | 100 kpsi |
| Operating Wavelength [Polarization-Maintaining Fiber for Components; Product Type: PMF15-125/245DP] | 1550 nm |
| Cutoff Wavelength [Polarization-Maintaining Fiber for Components; Product Type: PMF15-125/245DP] | 1290-1520 nm |
| Mode Field Diameter [Polarization-Maintaining Fiber for Components; Product Type: PMF15-125/245DP] | 10.5±0.5 |
| Beat Length [Polarization-Maintaining Fiber for Components; Product Type: PMF15-125/245DP] | ≤5.0 mm |
| Attenuation [Polarization-Maintaining Fiber for Components; Product Type: PMF15-125/245DP] | ≤0.6 dB/km |
| Polarization Crosstalk [Polarization-Maintaining Fiber for Components; Product Type: PMF15-125/245DP] | ≤-40 dB/4m |
| Polarization Crosstalk [Polarization-Maintaining Fiber for Components; Product Type: PMF15-125/245DP] | ≤-30 dB/100m |
| Cladding Diameter [Polarization-Maintaining Fiber for Components; Product Type: PMF15-125/245DP] | 125.0±1.0 |
| Coating Diameter [Polarization-Maintaining Fiber for Components; Product Type: PMF15-125/245DP] | 245.0±3.0 |
| Core-Cladding Concentricity [Polarization-Maintaining Fiber for Components; Product Type: PMF15-125/245DP] | ≤1.0 μm |
| Cladding Non-Circularity [Polarization-Maintaining Fiber for Components; Product Type: PMF15-125/245DP] | ≤1 % |
| Coating Noncircularity [Polarization-Maintaining Fiber for Components; Product Type: PMF15-125/245DP] | ≤5 % |
| Operating Temperature Range [Polarization-Maintaining Fiber for Components; Product Type: PMF15-125/245DP] | -45~+85 °C |
| Proof-Test Level [Polarization-Maintaining Fiber for Components; Product Type: PMF15-125/245DP] | 100 kpsi |
Applications
Key Features
Datasheet
Please provide your email to download the datasheet.
Invalid email format. Please try again.
Supplier Information
Loading...
Name
Phone
Organization
Use Case

Database Platform