Whispering-Gallery Optical Microcavity PY-MR-MF-D-M001

Whispering-Gallery Optical Microcavity PY-MR-MF-D-M001

Supplier
Jcoptix
Part Number
PY-MR-MF-D-M001
Category
Fiber Optomechanics
Origin
China

JCOPTIX whispering-gallery optical microcavities confine light by total internal reflection at curved surfaces, creating high-Q resonators with evanescent input/output coupling. High Q, small mode volume, strong field enhancement, and narrow linewidth suit narrow-linewidth lasers, optical oscillators, soliton sources, nonlinear optics, and precision sensing. Multiple models and extensive customization are available; contact support. Whispering-gallery microcavities. Models: PY-MR-MF-D-M001, PY-MR-CA-D-M001, PY-MR-MF-D-M101, PY-MR-CA-D-M101, PY-MR-MF-D-M011, PY-MR-CA-D-M011. High Q; low cavity loss; high nonlinear coefficient; environmental robustness. Ultraprecision-machined MgF₂/CaF₂ fluoride crystals provide ultrahigh Q, ultralow loss, high nonlinearity, and strongly hydrophobic surfaces. Packaged microdisks improve parameter stability/lifetime; contact support for customization. Technical reference table 1: Magnesium fluoride, MgF₂: no=1.37 at 1.55 μm; transmission window 0.15-7.00; thermal expansion (10⁻⁶/k) 8.8c, 13.1a. Calcium fluoride, CaF₂: no=1.42 at 1.55 μm; window 0.16-7.00; thermal expansion (10⁻⁶/k) 18.85. Technical reference table 2: Magnesium-fluoride microdisk MFD, fully enclosed steel package, diameter 2-5 mm, Q>10⁸, linewidth at 1550nm <2 MHz, FSR 35-3.5 GHz, F≈17500. Magnesium-fluoride MFD, fully enclosed steel package, diameter 5-20 mm, Q>10⁹, linewidth at 1550nm <0.2 MHz, FSR 35-3.5 GHz, F≈17500. Calcium-fluoride microdisk CFD, fully enclosed steel package, diameter 2-5 mm, Q>10⁸, linewidth at 1550nm <2 MHz, FSR 33-3.3 GHz, F≈16500. Calcium-fluoride CFD, fully enclosed steel package, diameter 5-20 mm, Q>10⁹, linewidth at 1550nm <0.2 MHz, FSR 33-3.3 GHz, F≈16500. Crystal microdisks use ultraprecision CaF₂/MgF₂ cavities. Compared with ordinary planar optics, they offer lower temperature sensitivity, high nonlinearity, long energy storage/retention, repeatability, ultrahigh Q, complete interfaces, and plug-and-play use. Standard FC/APC is available; FC/PC, LC, SC, LT, and other connectors are customizable. Material index, transmission window, and expansion guide selection. FSR, cavity size, and interfaces can be customized for nonstandard environments, nonlinear optics, precision sensing, or low-noise optical time/frequency transfer. Material table, columns name/formula/index/window/thermal expansion 10⁻⁶/k: Magnesium fluoride, MgF₂: no=1.37 at 1.55 μm; transmission window 0.15-7.00; thermal expansion 8.8c, 13.1a. Calcium fluoride, CaF₂: no=1.42 at 1.55 μm; window 0.16-7.00; thermal expansion 18.85. Table 1. Crystal-microdisk material parameters. Selection table, columns model/product/package/diameter in mm/Q/linewidth at 1550nm/FSR/finesse F: Magnesium-fluoride microdisk MFD, fully enclosed steel package, diameter 2-5 mm, Q>10⁸, linewidth <2 MHz, FSR 35-3.5 GHz, F≈17500. Magnesium-fluoride MFD, fully enclosed steel package, diameter 5-20 mm, Q>10⁹, linewidth <0.2 MHz, FSR 35-3.5 GHz, F≈17500. Calcium-fluoride microdisk CFD, fully enclosed steel package, diameter 2-5 mm, Q>10⁸, linewidth <2 MHz, FSR 33-3.3 GHz, F≈16500. Calcium-fluoride CFD, fully enclosed steel package, diameter 5-20 mm, Q>10⁹, linewidth <0.2 MHz, FSR 33-3.3 GHz, F≈16500. Table 2. Microdisk selection, WGMR-MF/CF/LN-D. FSR estimates depend on effective index and diameter; different modes have different effective indices. Application value comes from high Q, narrow resonances, strong enhancement, and sensitive responses to environmental disturbances. Uses include ultranarrow lasers, microcavity nonlinear optics, photoacoustics, physical sensing, biochemical detection, ultrastable frequency references, and optical gyroscopes. JCOPTIX supplies cavities plus packaging/coupling, stability management, thermal tuning, and interface customization. They lower research barriers to high-Q devices and provide instrument/industrial teams an expandable path from components to modules. For precision metrology, communications, biomedicine, and quantum sensing, ultrahigh-Q cavities link basic research and engineering; application-specific customization is available. Thermal compensation improves stability and overcomes frequency drift as stated. Ultrahigh Q/stability, narrow modes, and small size facilitate integration for gyroscopes, particle/acoustic sensors, light-matter studies, and ultrasensitive broadband ultrasound. Before delivery, national-/industry-standard procedures test temperature/humidity, salt spray, vibration, acceleration, drops, failure analysis, and aging, with good performance reported. Devices ship packaged or unpackaged. Packaging extends life, limits Q degradation, adds functions, and isolates thermal/vibration disturbances. Resonant-mode distribution and typical linewidth: FSR≈c/(n_g*L). The source defines cc as vacuum light speed, n_g as frequency-dependent group index, and L as optical-path length. For custom spherical cavities the geometric circumference is 2π*R. FSR is a fixed frequency interval determining sparse/dense modal distribution: larger FSR separates modes more, smaller FSR packs them closer. Geometry dominates; smaller cavities generally have larger FSR. Resolving modes also depends on linewidth Δν, normally FWHM, with Q=ν/Δν. Q measures storage ability and total absorption/scattering/radiation loss; high Q and suitable FSR jointly determine spectra. Crystal characteristics include low absorption/scattering, controllable index dispersion, anisotropy, and thermal stability. Precision crystal cavities can have higher Q than conventional silicon devices and more consistent mode spacing than amorphous cavities. JCOPTIX illustrates mode distributions for 1. fused silica, 2. MgF₂, 3. CaF₂.

Request a Quote Download Datasheet
Save to Favorites Save to Favorites

Overview

JCOPTIX whispering-gallery optical microcavities confine light by total internal reflection at curved surfaces, creating high-Q resonators with evanescent input/output coupling. High Q, small mode volume, strong field enhancement, and narrow linewidth suit narrow-linewidth lasers, optical oscillators, soliton sources, nonlinear optics, and precision sensing. Multiple models and extensive customization are available; contact support. Whispering-gallery microcavities. Models: PY-MR-MF-D-M001, PY-MR-CA-D-M001, PY-MR-MF-D-M101, PY-MR-CA-D-M101, PY-MR-MF-D-M011, PY-MR-CA-D-M011. High Q; low cavity loss; high nonlinear coefficient; environmental robustness. Ultraprecision-machined MgF₂/CaF₂ fluoride crystals provide ultrahigh Q, ultralow loss, high nonlinearity, and strongly hydrophobic surfaces. Packaged microdisks improve parameter stability/lifetime; contact support for customization. Technical reference table 1: Magnesium fluoride, MgF₂: no=1.37 at 1.55 μm; transmission window 0.15-7.00; thermal expansion (10⁻⁶/k) 8.8c, 13.1a. Calcium fluoride, CaF₂: no=1.42 at 1.55 μm; window 0.16-7.00; thermal expansion (10⁻⁶/k) 18.85. Technical reference table 2: Magnesium-fluoride microdisk MFD, fully enclosed steel package, diameter 2-5 mm, Q>10⁸, linewidth at 1550nm <2 MHz, FSR 35-3.5 GHz, F≈17500. Magnesium-fluoride MFD, fully enclosed steel package, diameter 5-20 mm, Q>10⁹, linewidth at 1550nm <0.2 MHz, FSR 35-3.5 GHz, F≈17500. Calcium-fluoride microdisk CFD, fully enclosed steel package, diameter 2-5 mm, Q>10⁸, linewidth at 1550nm <2 MHz, FSR 33-3.3 GHz, F≈16500. Calcium-fluoride CFD, fully enclosed steel package, diameter 5-20 mm, Q>10⁹, linewidth at 1550nm <0.2 MHz, FSR 33-3.3 GHz, F≈16500. Crystal microdisks use ultraprecision CaF₂/MgF₂ cavities. Compared with ordinary planar optics, they offer lower temperature sensitivity, high nonlinearity, long energy storage/retention, repeatability, ultrahigh Q, complete interfaces, and plug-and-play use. Standard FC/APC is available; FC/PC, LC, SC, LT, and other connectors are customizable. Material index, transmission window, and expansion guide selection. FSR, cavity size, and interfaces can be customized for nonstandard environments, nonlinear optics, precision sensing, or low-noise optical time/frequency transfer. Material table, columns name/formula/index/window/thermal expansion 10⁻⁶/k: Magnesium fluoride, MgF₂: no=1.37 at 1.55 μm; transmission window 0.15-7.00; thermal expansion 8.8c, 13.1a. Calcium fluoride, CaF₂: no=1.42 at 1.55 μm; window 0.16-7.00; thermal expansion 18.85. Table 1. Crystal-microdisk material parameters. Selection table, columns model/product/package/diameter in mm/Q/linewidth at 1550nm/FSR/finesse F: Magnesium-fluoride microdisk MFD, fully enclosed steel package, diameter 2-5 mm, Q>10⁸, linewidth <2 MHz, FSR 35-3.5 GHz, F≈17500. Magnesium-fluoride MFD, fully enclosed steel package, diameter 5-20 mm, Q>10⁹, linewidth <0.2 MHz, FSR 35-3.5 GHz, F≈17500. Calcium-fluoride microdisk CFD, fully enclosed steel package, diameter 2-5 mm, Q>10⁸, linewidth <2 MHz, FSR 33-3.3 GHz, F≈16500. Calcium-fluoride CFD, fully enclosed steel package, diameter 5-20 mm, Q>10⁹, linewidth <0.2 MHz, FSR 33-3.3 GHz, F≈16500. Table 2. Microdisk selection, WGMR-MF/CF/LN-D. FSR estimates depend on effective index and diameter; different modes have different effective indices. Application value comes from high Q, narrow resonances, strong enhancement, and sensitive responses to environmental disturbances. Uses include ultranarrow lasers, microcavity nonlinear optics, photoacoustics, physical sensing, biochemical detection, ultrastable frequency references, and optical gyroscopes. JCOPTIX supplies cavities plus packaging/coupling, stability management, thermal tuning, and interface customization. They lower research barriers to high-Q devices and provide instrument/industrial teams an expandable path from components to modules. For precision metrology, communications, biomedicine, and quantum sensing, ultrahigh-Q cavities link basic research and engineering; application-specific customization is available. Thermal compensation improves stability and overcomes frequency drift as stated. Ultrahigh Q/stability, narrow modes, and small size facilitate integration for gyroscopes, particle/acoustic sensors, light-matter studies, and ultrasensitive broadband ultrasound. Before delivery, national-/industry-standard procedures test temperature/humidity, salt spray, vibration, acceleration, drops, failure analysis, and aging, with good performance reported. Devices ship packaged or unpackaged. Packaging extends life, limits Q degradation, adds functions, and isolates thermal/vibration disturbances. Resonant-mode distribution and typical linewidth: FSR≈c/(n_g*L). The source defines cc as vacuum light speed, n_g as frequency-dependent group index, and L as optical-path length. For custom spherical cavities the geometric circumference is 2π*R. FSR is a fixed frequency interval determining sparse/dense modal distribution: larger FSR separates modes more, smaller FSR packs them closer. Geometry dominates; smaller cavities generally have larger FSR. Resolving modes also depends on linewidth Δν, normally FWHM, with Q=ν/Δν. Q measures storage ability and total absorption/scattering/radiation loss; high Q and suitable FSR jointly determine spectra. Crystal characteristics include low absorption/scattering, controllable index dispersion, anisotropy, and thermal stability. Precision crystal cavities can have higher Q than conventional silicon devices and more consistent mode spacing than amorphous cavities. JCOPTIX illustrates mode distributions for 1. fused silica, 2. MgF₂, 3. CaF₂.

Specifications

ParameterValue
Figure of Merit~10⁹
Applicable Wavelength1550 nm
Coupling MethodTapered Fiber Coupling
Damage Threshold21.8 dBm (150 mW)
Operating Temperature Range15~35 ℃
Interface TypeFC/APC
Package TypeFully Enclosed Aluminum Housing
Package Dimensions59 mm × 25 mm × 14.2 mm
Suitable EnvironmentNonclean Laboratory
Cavity MaterialMgF₂
Cavity Dimensions (Customizable) [Customizable; Listed Standard Specifications]Ø10 mm
Free Spectral Range (Customizable) [Customizable; Listed Standard Specifications]7 GHz
Tuning FunctionTemperature-Controlled Tuning
FWHM<0.1 MHz or <1 MHz
Insertion Loss [off resonance]<1.5 dB(off resonance)
Refractive Index [Material Parameter Table: Magnesium Fluoride (MgF₂), Cavity Material Property; @1.55 μm]no=1.37(@1.55 μm)
Transmission Window [Material Parameter Table: Magnesium Fluoride (MgF₂), Cavity Material Property; Source Does Not Specify Transmission Window Unit]0.15-7.00
Coefficient of Thermal Expansion [Material Parameter Table: Magnesium Fluoride (MgF₂), Cavity Material Property; Crystal Axes Retain Original c/a Labels]8.8c, 13.1a

Key Features

Compact Package, Complete Interfaces, Plug and Play

Datasheet

Please provide your email to download the datasheet.

Your name
Email Address

Invalid email format. Please try again.

Send Request

Supplier Information

Jc
Jcoptix
View Supplier →
Nanjing Jingcui Optical Technology Co., Ltd. (formerly Suzhou Jingcui Optical Technology Co., Ltd., abbreviated as JCOPTIX) is a national high-tech enterprise and a national-level specialized and sophisticated 'little giant' enterprise, established on the foundation of the Liquid Crystal and Photonics Research Center of Nanjing University. It engages in R&D, manufacturing, and sales of advanced optical technologies and products. JCOPTIX is dedicated to building a product platform for China's optical community, offering liquid crystal photonics components, precision optical components, optomechanics, fiber optic assemblies, motion control devices, and system solutions. All listed products can be found and ordered online at www.JCOPTIX.com.

Request a Quote

Our team responds within 24–48 hours
Whispering-Gallery Optical Microcavity PY-MR-MF-D-M001
Jcoptix · Fiber Optomechanics
Direct from Manufacturer
Your inquiry will be sent directly to the manufacturer
Photonics Source Platform
We handles the inquiry on your behalf
Your information is protected and will never be shared without consent.
Contact Us

Loading...

GetExperimental Plan

Name

Phone

+86

Organization

Use Case

AI Parametric Selection
Smart Match · Precise Recs
Enter Specifications
AI Smart Matching
Get Best Matches
Skip Manual Comparison
Find Best Solutions Fast
Select Now →