Cold Thermal Impact Test Box STSII Series
The results of the results of the chemical changes or physical injuries caused by the cold-heated contraction of the sample itself, which are available at short notice to detect the degree to which the sample is tolerated in a continuous environment of extreme and extremely low temperatures at short notice, can be used as an important basis for the next production, development and development of the sample itself. The two-box cold-heat-impact test boxes are divided into high- and low-temperature chambers, which are a basket, and are also called “scaling-heat-sh-testing boxes” and are placed in the basket. When the heat is tested, the basket is raised to high-temperature rooms; when the temperature is low, the basket is lowered to low-temperature rooms.
Overview
Specifications
| Parameter | Value |
|---|---|
| Volume [STSⅡ60-40W] | 60 L |
| Box size (mm)-W [STSⅡ60-40W] | 400 mm |
| Box size (mm)-H [STSⅡ60-40W] | 370 mm |
| Box size (mm)-D [STSⅡ60-40W] | 430 mm |
| Outer box size (mm)-W [STSⅡ60-40W] | 860 mm |
| Outer box size (mm)-H [STSⅡ60-40W] | 2000 mm |
| Outer box dimensions (mm)-D [STSⅡ60-40W] | 2050 mm |
| Maximum sample weight [STSⅡ60-40W] | 20 kg |
| Test Method [STSⅡ60-40W] | Scandles in test area up or down |
| Preheat pre-cold temperature [STSⅡ60-40W] | Preheat: (60 ~ 185) °C Precipice: (-80 ~ 5) °C |
| Temperature recovery/toggle time [STSⅡ60-40W] | Recovery time: 2-5min Switch time: ≤10s |
| Temperature deviation [STSⅡ60-40W] | ±2.0 ℃ |
| Exposure Time [High/low temperature exposure; STSII60-40W] | High-temperature exposure:30min; low-temperature exposure:30min |
| Weight [STSⅡ60-40W] | 880 kg |
| Maximum Current [STSⅡ60-40W] | 30 A |
| Power Supply Power [STSⅡ60-40W] | 20 kW |
| Cooling Water Flow Rate [STSⅡ60-40W] | 4 t/h |
| Materials - Boxes [STSⅡ60-40W] | SUS304 Stainless Steel Plate |
| Materials - outer boxes [STSⅡ60-40W] | Double-sided zinc-plating steel, surface treatment and electrostatic spray treatment |
| Materials - Temperature [STSⅡ60-40W] | Fibres, Khmer + polyamino hair bubble |
| Executor - High Temperature Cell [STSⅡ60-40W] | Heating machines: Importing nickel chromium alloy hair heaters, heat shock winders, axle winders during preheating |
| Executor - Low Temperature Cell [STSⅡ60-40W] | Heating machines: Imported nickel alloyed hairline chillers: tablet aluminium panels Wind machines: cooling wind machines |
| Executor -- homing basket driver [STSⅡ60-40W] | Electric screw drive moves the specimen basket vertically; motor drive(380V) |
| Executor - Refrigeration System [STSⅡ60-40W] | Piston compressor with binary cascade refrigeration; environmentally friendly refrigerants R404A and R23 |
| Control system - Touch screen + PLC [STSⅡ60-40W] | 7.0 "or 10.0", 800 × 480 resolution, Mixed output PLC |
| Control system -- mode of operation [STSⅡ60-40W] | Program Run, Time Run |
| Control system -- set [STSⅡ60-40W] | CREDIT + English, Touch input |
| Controller system - program capacity [STSⅡ60-40W] | 96 programs,3 segments each;32000 cycles can be set; program-linking functionality |
| Control system -- set range [STSⅡ60-40W] | Adjustments to the maximum range of equipment performance ± 5.0°C |
| Control system - display resolution [STSⅡ60-40W] | Temperature: 0.1°C, time:s |
| Controller system -- sensors [STSⅡ60-40W] | PT100 (Pilpium Retardation) |
| Controller system - control method [STSⅡ60-40W] | Cold-temperature balance + anti-saturation PID + self-regulating |
| Control system - Curve record [STSⅡ60-40W] | Have electrical data preservation capability, which allows slide viewing and mapping of data on screen |
| Control system -- additional function [STSⅡ60-40W] | The alarm will pop up the cause of the alarm, the time switch, power outage protection, user access. |
| Control system -- communication function [STSⅡ60-40W] | Support for communication, including RS485, LAN (web portal), GPRS (cell phone), for remote monitoring, data collection: IBM PC compatible, memory above PII CPU, 128M, CREDIT operating system |
| Controller system -- data acquisition [STSⅡ60-40W] | 1. USB supports storage of3 months of curve data and download of historical curves/data.2. Large built-in storage replaces a recorder or PC storage:3 months of continuous24-hour data at1-minute sampling. USB-drive export of selected historical times produces CSV files.3. Optional PC connection uses monitoring software to record data/display curves and enables the PC to serve as a remote-monitoring terminal. |
| Compressed Air [STSⅡ60-40W] | Pressure: 0.5 ~ 0.7 MPa flow: 0.1 cubics |
| Cold water. [STSⅡ60-40W] | Water pressure: 0.25 ~ 0.4 MPa Water temperature: ≤30°C |
| Power (V)/ [STSⅡ60-40W] | AC voltage 380V±38V; frequency 50Hz±0.5Hz; three-phase four-wire + protective grounding |
| Security devices [STSⅡ60-40W] | Fault switches, electrics, compressors, sequences, super-temperature protections. |
| Volume [STSⅡ125-40W] | 125 L |
| Box size (mm)-W [STSⅡ125-40W] | 470 mm |
| Box size (mm)-H [STSⅡ125-40W] | 410 mm |
| Box size (mm)-D [STSⅡ125-40W] | 650 mm |
| Outer box size (mm)-W [STSⅡ125-40W] | 875 mm |
| Outer box size (mm)-H [STSⅡ125-40W] | 2000 mm |
| Outer box dimensions (mm)-D [STSⅡ125-40W] | 2250 mm |
| Maximum sample weight [STSⅡ125-40W] | 50 kg |
| Test Method [STSⅡ125-40W] | Scandles in test area up or down |
| Preheat pre-cold temperature [STSⅡ125-40W] | Preheat: (60 ~ 185) °C Precipice: (-80 ~ 5) °C |
| Temperature recovery/toggle time [STSⅡ125-40W] | Recovery time: 2-5min Switch time: ≤10s |
| Temperature deviation [STSⅡ125-40W] | ±2.0 ℃ |
| Exposure Time [High/low temperature exposure; STSII125-40W] | High-temperature exposure:30min; low-temperature exposure:30min |
| Weight [STSⅡ125-40W] | 950 kg |
| Maximum Current [STSⅡ125-40W] | 42 A |
| Power Supply Power [STSⅡ125-40W] | 20 kW |
| Cooling Water Flow Rate [STSⅡ125-40W] | 5 t/h |
| Materials - Boxes [STSⅡ125-40W] | SUS304 Stainless Steel Plate |
| Materials - outer boxes [STSⅡ125-40W] | Double-sided zinc-plating steel, surface treatment and electrostatic spray treatment |
| Materials - Temperature [STSⅡ125-40W] | Fibres, Khmer + polyamino hair bubble |
| Executor - High Temperature Cell [STSⅡ125-40W] | Heating machines: Importing nickel chromium alloy hair heaters, heat shock winders, axle winders during preheating |
| Executor - Low Temperature Cell [STSⅡ125-40W] | Heating machines: Imported nickel alloyed hairline chillers: tablet aluminium panels Wind machines: cooling wind machines |
| Executor -- homing basket driver [STSⅡ125-40W] | Electric screw drive moves the specimen basket vertically; motor drive(380V) |
| Executor - Refrigeration System [STSⅡ125-40W] | Piston compressor with binary cascade refrigeration; environmentally friendly refrigerants R404A and R23 |
| Control system - Touch screen + PLC [STSⅡ125-40W] | 7.0 "or 10.0", 800 × 480 resolution, Mixed output PLC |
| Control system -- mode of operation [STSⅡ125-40W] | Program Run, Time Run |
| Control system -- set [STSⅡ125-40W] | CREDIT + English, Touch input |
| Controller system - program capacity [STSⅡ125-40W] | 96 programs,3 segments each;32000 cycles can be set; program-linking functionality |
| Control system -- set range [STSⅡ125-40W] | Adjustments to the maximum range of equipment performance ± 5.0°C |
| Control system - display resolution [STSⅡ125-40W] | Temperature: 0.1°C, time:s |
| Controller system -- sensors [STSⅡ125-40W] | PT100 (Pilpium Retardation) |
| Controller system - control method [STSⅡ125-40W] | Cold-temperature balance + anti-saturation PID + self-regulating |
| Control system - Curve record [STSⅡ125-40W] | Have electrical data preservation capability, which allows slide viewing and mapping of data on screen |
| Control system -- additional function [STSⅡ125-40W] | The alarm will pop up the cause of the alarm, the time switch, power outage protection, user access. |
| Control system -- communication function [STSⅡ125-40W] | Support for communication, including RS485, LAN (web portal), GPRS (cell phone), for remote monitoring, data collection: IBM PC compatible, memory above PII CPU, 128M, CREDIT operating system |
| Controller system -- data acquisition [STSⅡ125-40W] | 1. USB supports storage of3 months of curve data and download of historical curves/data.2. Large built-in storage replaces a recorder or PC storage:3 months of continuous24-hour data at1-minute sampling. USB-drive export of selected historical times produces CSV files.3. Optional PC connection uses monitoring software to record data/display curves and enables the PC to serve as a remote-monitoring terminal. |
| Compressed Air [STSⅡ125-40W] | Pressure: 0.5 ~ 0.7 MPa flow: 0.1 cubics |
| Cold water. [STSⅡ125-40W] | Water pressure: 0.25 ~ 0.4 MPa Water temperature: ≤30°C |
| Power (V)/ [STSⅡ125-40W] | AC voltage 380V±38V; frequency 50Hz±0.5Hz; three-phase four-wire + protective grounding |
| Security devices [STSⅡ125-40W] | Fault switches, electrics, compressors, sequences, super-temperature protections. |
| Volume [STSⅡ200-40W] | 200 L |
| Box size (mm)-W [STSⅡ200-40W] | 770 mm |
| Box size (mm)-H [STSⅡ200-40W] | 610 mm |
| Box size (mm)-D [STSⅡ200-40W] | 450 mm |
| Outer box size (mm)-W [STSⅡ200-40W] | 1190 mm |
| Outer box size (mm)-H [STSⅡ200-40W] | 2400 mm |
| Outer box dimensions (mm)-D [STSⅡ200-40W] | 2250 mm |
| Maximum sample weight [STSⅡ200-40W] | 70 kg |
| Test Method [STSⅡ200-40W] | Scandles in test area up or down |
| Preheat pre-cold temperature [STSⅡ200-40W] | Preheat: (60 ~ 185) °C Precipice: (-80 ~ 5) °C |
| Temperature recovery/toggle time [STSⅡ200-40W] | Recovery time: 2-5min Switch time: ≤10s |
| Temperature deviation [STSⅡ200-40W] | ±2.0 ℃ |
| Exposure Time [High/low temperature exposure; STSII200-40W] | High-temperature exposure:30min; low-temperature exposure:30min |
| Weight [STSⅡ200-40W] | 1100 kg |
| Maximum Current [STSⅡ200-40W] | 47 A |
| Power Supply Power [STSⅡ200-40W] | 25 kW |
| Cooling Water Flow Rate [STSⅡ200-40W] | 7 t/h |
| Materials - Boxes [STSⅡ200-40W] | SUS304 Stainless Steel Plate |
| Materials - outer boxes [STSⅡ200-40W] | Double-sided zinc-plating steel, surface treatment and electrostatic spray treatment |
| Materials - Temperature [STSⅡ200-40W] | Fibres, Khmer + polyamino hair bubble |
| Executor - High Temperature Cell [STSⅡ200-40W] | Heating machines: Importing nickel chromium alloy hair heaters, heat shock winders, axle winders during preheating |
| Executor - Low Temperature Cell [STSⅡ200-40W] | Heating machines: Imported nickel alloyed hairline chillers: tablet aluminium panels Wind machines: cooling wind machines |
| Executor -- homing basket driver [STSⅡ200-40W] | Electric screw drive moves the specimen basket vertically; motor drive(380V) |
| Executor - Refrigeration System [STSⅡ200-40W] | Piston compressor with binary cascade refrigeration; environmentally friendly refrigerants R404A and R23 |
| Control system - Touch screen + PLC [STSⅡ200-40W] | 7.0 "or 10.0", 800 × 480 resolution, Mixed output PLC |
| Control system -- mode of operation [STSⅡ200-40W] | Program Run, Time Run |
| Control system -- set [STSⅡ200-40W] | CREDIT + English, Touch input |
| Controller system - program capacity [STSⅡ200-40W] | 96 programs,3 segments each;32000 cycles can be set; program-linking functionality |
| Control system -- set range [STSⅡ200-40W] | Adjustments to the maximum range of equipment performance ± 5.0°C |
| Control system - display resolution [STSⅡ200-40W] | Temperature: 0.1°C, time:s |
| Controller system -- sensors [STSⅡ200-40W] | PT100 (Pilpium Retardation) |
| Controller system - control method [STSⅡ200-40W] | Cold-temperature balance + anti-saturation PID + self-regulating |
| Control system - Curve record [STSⅡ200-40W] | Have electrical data preservation capability, which allows slide viewing and mapping of data on screen |
| Control system -- additional function [STSⅡ200-40W] | The alarm will pop up the cause of the alarm, the time switch, power outage protection, user access. |
| Control system -- communication function [STSⅡ200-40W] | Support for communication, including RS485, LAN (web portal), GPRS (cell phone), for remote monitoring, data collection: IBM PC compatible, memory above PII CPU, 128M, CREDIT operating system |
| Controller system -- data acquisition [STSⅡ200-40W] | 1. USB supports storage of3 months of curve data and download of historical curves/data.2. Large built-in storage replaces a recorder or PC storage:3 months of continuous24-hour data at1-minute sampling. USB-drive export of selected historical times produces CSV files.3. Optional PC connection uses monitoring software to record data/display curves and enables the PC to serve as a remote-monitoring terminal. |
| Compressed Air [STSⅡ200-40W] | Pressure: 0.5 ~ 0.7 MPa flow: 0.1 cubics |
| Cold water. [STSⅡ200-40W] | Water pressure: 0.25 ~ 0.4 MPa Water temperature: ≤30°C |
| Power (V)/ [STSⅡ200-40W] | AC voltage 380V±38V; frequency 50Hz±0.5Hz; three-phase four-wire + protective grounding |
| Security devices [STSⅡ200-40W] | Fault switches, electrics, compressors, sequences, super-temperature protections. |
| Volume [STSⅡ300-40W] | 300 L |
| Box size (mm)-W [STSⅡ300-40W] | 770 mm |
| Box size (mm)-H [STSⅡ300-40W] | 610 mm |
| Box size (mm)-D [STSⅡ300-40W] | 650 mm |
| Outer box size (mm)-W [STSⅡ300-40W] | 1190 mm |
| Outer box size (mm)-H [STSⅡ300-40W] | 2400 mm |
| Outer box dimensions (mm)-D [STSⅡ300-40W] | 2450 mm |
| Maximum sample weight [STSⅡ300-40W] | 80 kg |
| Test Method [STSⅡ300-40W] | Scandles in test area up or down |
| Preheat pre-cold temperature [STSⅡ300-40W] | Preheat: (60 ~ 185) °C Precipice: (-80 ~ 5) °C |
| Temperature recovery/toggle time [STSⅡ300-40W] | Recovery time: 2-5min Switch time: ≤10s |
| Temperature deviation [STSⅡ300-40W] | ±2.0 ℃ |
| Exposure Time [High/low temperature exposure; STSII300-40W] | High-temperature exposure:30min; low-temperature exposure:30min |
| Weight [STSⅡ300-40W] | 1300 kg |
| Maximum Current [STSⅡ300-40W] | 52 A |
| Power Supply Power [STSⅡ300-40W] | 30 kW |
| Cooling Water Flow Rate [STSⅡ300-40W] | 9 t/h |
| Materials - Boxes [STSⅡ300-40W] | SUS304 Stainless Steel Plate |
| Materials - outer boxes [STSⅡ300-40W] | Double-sided zinc-plating steel, surface treatment and electrostatic spray treatment |
| Materials - Temperature [STSⅡ300-40W] | Fibres, Khmer + polyamino hair bubble |
| Executor - High Temperature Cell [STSⅡ300-40W] | Heating machines: Importing nickel chromium alloy hair heaters, heat shock winders, axle winders during preheating |
| Executor - Low Temperature Cell [STSⅡ300-40W] | Heating machines: Imported nickel alloyed hairline chillers: tablet aluminium panels Wind machines: cooling wind machines |
| Executor -- homing basket driver [STSⅡ300-40W] | Electric screw drive moves the specimen basket vertically; motor drive(380V) |
| Executor - Refrigeration System [STSⅡ300-40W] | Piston compressor with binary cascade refrigeration; environmentally friendly refrigerants R404A and R23 |
| Control system - Touch screen + PLC [STSⅡ300-40W] | 7.0 "or 10.0", 800 × 480 resolution, Mixed output PLC |
| Control system -- mode of operation [STSⅡ300-40W] | Program Run, Time Run |
| Control system -- set [STSⅡ300-40W] | CREDIT + English, Touch input |
| Controller system - program capacity [STSⅡ300-40W] | 96 programs,3 segments each;32000 cycles can be set; program-linking functionality |
| Control system -- set range [STSⅡ300-40W] | Adjustments to the maximum range of equipment performance ± 5.0°C |
| Control system - display resolution [STSⅡ300-40W] | Temperature: 0.1°C, time:s |
| Controller system -- sensors [STSⅡ300-40W] | PT100 (Pilpium Retardation) |
| Controller system - control method [STSⅡ300-40W] | Cold-temperature balance + anti-saturation PID + self-regulating |
| Control system - Curve record [STSⅡ300-40W] | Have electrical data preservation capability, which allows slide viewing and mapping of data on screen |
| Control system -- additional function [STSⅡ300-40W] | The alarm will pop up the cause of the alarm, the time switch, power outage protection, user access. |
| Control system -- communication function [STSⅡ300-40W] | Support for communication, including RS485, LAN (web portal), GPRS (cell phone), for remote monitoring, data collection: IBM PC compatible, memory above PII CPU, 128M, CREDIT operating system |
| Controller system -- data acquisition [STSⅡ300-40W] | 1. USB supports storage of3 months of curve data and download of historical curves/data.2. Large built-in storage replaces a recorder or PC storage:3 months of continuous24-hour data at1-minute sampling. USB-drive export of selected historical times produces CSV files.3. Optional PC connection uses monitoring software to record data/display curves and enables the PC to serve as a remote-monitoring terminal. |
| Compressed Air [STSⅡ300-40W] | Pressure: 0.5 ~ 0.7 MPa flow: 0.1 cubics |
| Cold water. [STSⅡ300-40W] | Water pressure: 0.25 ~ 0.4 MPa Water temperature: ≤30°C |
| Power (V)/ [STSⅡ300-40W] | AC voltage 380V±38V; frequency 50Hz±0.5Hz; three-phase four-wire + protective grounding |
| Security devices [STSⅡ300-40W] | Fault switches, electrics, compressors, sequences, super-temperature protections. |
| Volume [STSⅡ60-55W] | 60 L |
| Box size (mm)-W [STSⅡ60-55W] | 400 mm |
| Box size (mm)-H [STSⅡ60-55W] | 370 mm |
| Box size (mm)-D [STSⅡ60-55W] | 430 mm |
| Outer box size (mm)-W [STSⅡ60-55W] | 860 mm |
| Outer box size (mm)-H [STSⅡ60-55W] | 2000 mm |
| Outer box dimensions (mm)-D [STSⅡ60-55W] | 2050 mm |
| Maximum sample weight [STSⅡ60-55W] | 20 kg |
| Test Method [STSⅡ60-55W] | Scandles in test area up or down |
| Preheat pre-cold temperature [STSⅡ60-55W] | Preheat: (60 ~ 185) °C Precipice: (-80 ~ 5) °C |
| Temperature recovery/toggle time [STSⅡ60-55W] | Recovery time: 2-5min Switch time: ≤10s |
| Temperature deviation [STSⅡ60-55W] | ±2.0 ℃ |
| Exposure Time [High/low temperature exposure; STSII60-55W] | High-temperature exposure:30min; low-temperature exposure:30min |
| Weight [STSⅡ60-55W] | 910 kg |
| Maximum Current [STSⅡ60-55W] | 42 A |
| Power Supply Power [STSⅡ60-55W] | 23 kW |
| Cooling Water Flow Rate [STSⅡ60-55W] | 7 t/h |
| Materials - Boxes [STSⅡ60-55W] | SUS304 Stainless Steel Plate |
| Materials - outer boxes [STSⅡ60-55W] | Double-sided zinc-plating steel, surface treatment and electrostatic spray treatment |
| Materials - Temperature [STSⅡ60-55W] | Fibres, Khmer + polyamino hair bubble |
| Executor - High Temperature Cell [STSⅡ60-55W] | Heating machines: Importing nickel chromium alloy hair heaters, heat shock winders, axle winders during preheating |
| Executor - Low Temperature Cell [STSⅡ60-55W] | Heating machines: Imported nickel alloyed hairline chillers: tablet aluminium panels Wind machines: cooling wind machines |
| Executor -- homing basket driver [STSⅡ60-55W] | Electric screw drive moves the specimen basket vertically; motor drive(380V) |
| Executor - Refrigeration System [STSⅡ60-55W] | Piston compressor with binary cascade refrigeration; environmentally friendly refrigerants R404A and R23 |
| Control system - Touch screen + PLC [STSⅡ60-55W] | 7.0 "or 10.0", 800 × 480 resolution, Mixed output PLC |
| Control system -- mode of operation [STSⅡ60-55W] | Program Run, Time Run |
| Control system -- set [STSⅡ60-55W] | CREDIT + English, Touch input |
| Controller system - program capacity [STSⅡ60-55W] | 96 programs,3 segments each;32000 cycles can be set; program-linking functionality |
| Control system -- set range [STSⅡ60-55W] | Adjustments to the maximum range of equipment performance ± 5.0°C |
| Control system - display resolution [STSⅡ60-55W] | Temperature: 0.1°C, time:s |
| Controller system -- sensors [STSⅡ60-55W] | PT100 (Pilpium Retardation) |
| Controller system - control method [STSⅡ60-55W] | Cold-temperature balance + anti-saturation PID + self-regulating |
| Control system - Curve record [STSⅡ60-55W] | Have electrical data preservation capability, which allows slide viewing and mapping of data on screen |
| Control system -- additional function [STSⅡ60-55W] | The alarm will pop up the cause of the alarm, the time switch, power outage protection, user access. |
| Control system -- communication function [STSⅡ60-55W] | Support for communication, including RS485, LAN (web portal), GPRS (cell phone), for remote monitoring, data collection: IBM PC compatible, memory above PII CPU, 128M, CREDIT operating system |
| Controller system -- data acquisition [STSⅡ60-55W] | 1. USB supports storage of3 months of curve data and download of historical curves/data.2. Large built-in storage replaces a recorder or PC storage:3 months of continuous24-hour data at1-minute sampling. USB-drive export of selected historical times produces CSV files.3. Optional PC connection uses monitoring software to record data/display curves and enables the PC to serve as a remote-monitoring terminal. |
| Compressed Air [STSⅡ60-55W] | Pressure: 0.5 ~ 0.7 MPa flow: 0.1 cubics |
| Cold water. [STSⅡ60-55W] | Water pressure: 0.25 ~ 0.4 MPa Water temperature: ≤30°C |
| Power (V)/ [STSⅡ60-55W] | AC voltage 380V±38V; frequency 50Hz±0.5Hz; three-phase four-wire + protective grounding |
| Security devices [STSⅡ60-55W] | Fault switches, electrics, compressors, sequences, super-temperature protections. |
| Volume [STSⅡ125-55W] | 125 L |
| Box size (mm)-W [STSⅡ125-55W] | 470 mm |
| Box size (mm)-H [STSⅡ125-55W] | 410 mm |
| Box size (mm)-D [STSⅡ125-55W] | 650 mm |
| Outer box size (mm)-W [STSⅡ125-55W] | 875 mm |
| Outer box size (mm)-H [STSⅡ125-55W] | 2000 mm |
| Outer box dimensions (mm)-D [STSⅡ125-55W] | 2250 mm |
| Maximum sample weight [STSⅡ125-55W] | 50 kg |
| Test Method [STSⅡ125-55W] | Scandles in test area up or down |
| Preheat pre-cold temperature [STSⅡ125-55W] | Preheat: (60 ~ 185) °C Precipice: (-80 ~ 5) °C |
| Temperature recovery/toggle time [STSⅡ125-55W] | Recovery time: 2-5min Switch time: ≤10s |
| Temperature deviation [STSⅡ125-55W] | ±2.0 ℃ |
| Exposure Time [High/low temperature exposure; STSII125-55W] | High-temperature exposure:30min; low-temperature exposure:30min |
| Weight [STSⅡ125-55W] | 980 kg |
| Maximum Current [STSⅡ125-55W] | 42 A |
| Power Supply Power [STSⅡ125-55W] | 23 kW |
| Cooling Water Flow Rate [STSⅡ125-55W] | 8 t/h |
| Materials - Boxes [STSⅡ125-55W] | SUS304 Stainless Steel Plate |
| Materials - outer boxes [STSⅡ125-55W] | Double-sided zinc-plating steel, surface treatment and electrostatic spray treatment |
| Materials - Temperature [STSⅡ125-55W] | Fibres, Khmer + polyamino hair bubble |
| Executor - High Temperature Cell [STSⅡ125-55W] | Heating machines: Importing nickel chromium alloy hair heaters, heat shock winders, axle winders during preheating |
| Executor - Low Temperature Cell [STSⅡ125-55W] | Heating machines: Imported nickel alloyed hairline chillers: tablet aluminium panels Wind machines: cooling wind machines |
| Executor -- homing basket driver [STSⅡ125-55W] | Electric screw drive moves the specimen basket vertically; motor drive(380V) |
| Executor - Refrigeration System [STSⅡ125-55W] | Piston compressor with binary cascade refrigeration; environmentally friendly refrigerants R404A and R23 |
| Control system - Touch screen + PLC [STSⅡ125-55W] | 7.0 "or 10.0", 800 × 480 resolution, Mixed output PLC |
| Control system -- mode of operation [STSⅡ125-55W] | Program Run, Time Run |
| Control system -- set [STSⅡ125-55W] | CREDIT + English, Touch input |
| Controller system - program capacity [STSⅡ125-55W] | 96 programs,3 segments each;32000 cycles can be set; program-linking functionality |
| Control system -- set range [STSⅡ125-55W] | Adjustments to the maximum range of equipment performance ± 5.0°C |
| Control system - display resolution [STSⅡ125-55W] | Temperature: 0.1°C, time:s |
| Controller system -- sensors [STSⅡ125-55W] | PT100 (Pilpium Retardation) |
| Controller system - control method [STSⅡ125-55W] | Cold-temperature balance + anti-saturation PID + self-regulating |
| Control system - Curve record [STSⅡ125-55W] | Have electrical data preservation capability, which allows slide viewing and mapping of data on screen |
| Control system -- additional function [STSⅡ125-55W] | The alarm will pop up the cause of the alarm, the time switch, power outage protection, user access. |
| Control system -- communication function [STSⅡ125-55W] | Support for communication, including RS485, LAN (web portal), GPRS (cell phone), for remote monitoring, data collection: IBM PC compatible, memory above PII CPU, 128M, CREDIT operating system |
| Controller system -- data acquisition [STSⅡ125-55W] | 1. USB supports storage of3 months of curve data and download of historical curves/data.2. Large built-in storage replaces a recorder or PC storage:3 months of continuous24-hour data at1-minute sampling. USB-drive export of selected historical times produces CSV files.3. Optional PC connection uses monitoring software to record data/display curves and enables the PC to serve as a remote-monitoring terminal. |
| Compressed Air [STSⅡ125-55W] | Pressure: 0.5 ~ 0.7 MPa flow: 0.1 cubics |
| Cold water. [STSⅡ125-55W] | Water pressure: 0.25 ~ 0.4 MPa Water temperature: ≤30°C |
| Power (V)/ [STSⅡ125-55W] | AC voltage 380V±38V; frequency 50Hz±0.5Hz; three-phase four-wire + protective grounding |
| Security devices [STSⅡ125-55W] | Fault switches, electrics, compressors, sequences, super-temperature protections. |
| Volume [STSⅡ200-55W] | 200 L |
| Box size (mm)-W [STSⅡ200-55W] | 770 mm |
| Box size (mm)-H [STSⅡ200-55W] | 610 mm |
| Box size (mm)-D [STSⅡ200-55W] | 450 mm |
| Outer box size (mm)-W [STSⅡ200-55W] | 1190 mm |
| Outer box size (mm)-H [STSⅡ200-55W] | 2400 mm |
| Outer box dimensions (mm)-D [STSⅡ200-55W] | 2250 mm |
| Maximum sample weight [STSⅡ200-55W] | 70 kg |
| Test Method [STSⅡ200-55W] | Scandles in test area up or down |
| Preheat pre-cold temperature [STSⅡ200-55W] | Preheat: (60 ~ 185) °C Precipice: (-80 ~ 5) °C |
| Temperature recovery/toggle time [STSⅡ200-55W] | Recovery time: 2-5min Switch time: ≤10s |
| Temperature deviation [STSⅡ200-55W] | ±2.0 ℃ |
| Exposure Time [High/low temperature exposure; STSII200-55W] | High-temperature exposure:30min; low-temperature exposure:30min |
| Weight [STSⅡ200-55W] | 1300 kg |
| Maximum Current [STSⅡ200-55W] | 55 A |
| Power Supply Power [STSⅡ200-55W] | 34 kW |
| Cooling Water Flow Rate [STSⅡ200-55W] | 9 t/h |
| Materials - Boxes [STSⅡ200-55W] | SUS304 Stainless Steel Plate |
| Materials - outer boxes [STSⅡ200-55W] | Double-sided zinc-plating steel, surface treatment and electrostatic spray treatment |
| Materials - Temperature [STSⅡ200-55W] | Fibres, Khmer + polyamino hair bubble |
| Executor - High Temperature Cell [STSⅡ200-55W] | Heating machines: Importing nickel chromium alloy hair heaters, heat shock winders, axle winders during preheating |
| Executor - Low Temperature Cell [STSⅡ200-55W] | Heating machines: Imported nickel alloyed hairline chillers: tablet aluminium panels Wind machines: cooling wind machines |
| Executor -- homing basket driver [STSⅡ200-55W] | Electric screw drive moves the specimen basket vertically; motor drive(380V) |
| Executor - Refrigeration System [STSⅡ200-55W] | Piston compressor with binary cascade refrigeration; environmentally friendly refrigerants R404A and R23 |
| Control system - Touch screen + PLC [STSⅡ200-55W] | 7.0 "or 10.0", 800 × 480 resolution, Mixed output PLC |
| Control system -- mode of operation [STSⅡ200-55W] | Program Run, Time Run |
| Control system -- set [STSⅡ200-55W] | CREDIT + English, Touch input |
| Controller system - program capacity [STSⅡ200-55W] | 96 programs,3 segments each;32000 cycles can be set; program-linking functionality |
| Control system -- set range [STSⅡ200-55W] | Adjustments to the maximum range of equipment performance ± 5.0°C |
| Control system - display resolution [STSⅡ200-55W] | Temperature: 0.1°C, time:s |
| Controller system -- sensors [STSⅡ200-55W] | PT100 (Pilpium Retardation) |
| Controller system - control method [STSⅡ200-55W] | Cold-temperature balance + anti-saturation PID + self-regulating |
| Control system - Curve record [STSⅡ200-55W] | Have electrical data preservation capability, which allows slide viewing and mapping of data on screen |
| Control system -- additional function [STSⅡ200-55W] | The alarm will pop up the cause of the alarm, the time switch, power outage protection, user access. |
| Control system -- communication function [STSⅡ200-55W] | Support for communication, including RS485, LAN (web portal), GPRS (cell phone), for remote monitoring, data collection: IBM PC compatible, memory above PII CPU, 128M, CREDIT operating system |
| Controller system -- data acquisition [STSⅡ200-55W] | 1. USB supports storage of3 months of curve data and download of historical curves/data.2. Large built-in storage replaces a recorder or PC storage:3 months of continuous24-hour data at1-minute sampling. USB-drive export of selected historical times produces CSV files.3. Optional PC connection uses monitoring software to record data/display curves and enables the PC to serve as a remote-monitoring terminal. |
| Compressed Air [STSⅡ200-55W] | Pressure: 0.5 ~ 0.7 MPa flow: 0.1 cubics |
| Cold water. [STSⅡ200-55W] | Water pressure: 0.25 ~ 0.4 MPa Water temperature: ≤30°C |
| Power (V)/ [STSⅡ200-55W] | AC voltage 380V±38V; frequency 50Hz±0.5Hz; three-phase four-wire + protective grounding |
| Security devices [STSⅡ200-55W] | Fault switches, electrics, compressors, sequences, super-temperature protections. |
| Volume [STSⅡ300-55W] | 300 L |
| Box size (mm)-W [STSⅡ300-55W] | 770 mm |
| Box size (mm)-H [STSⅡ300-55W] | 610 mm |
| Box size (mm)-D [STSⅡ300-55W] | 650 mm |
| Outer box size (mm)-W [STSⅡ300-55W] | 1470 mm |
| Outer box size (mm)-H [STSⅡ300-55W] | 2200 mm |
| Outer box dimensions (mm)-D [STSⅡ300-55W] | 2500 mm |
| Maximum sample weight [STSⅡ300-55W] | 80 kg |
| Test Method [STSⅡ300-55W] | Scandles in test area up or down |
| Preheat pre-cold temperature [STSⅡ300-55W] | Preheat: (60 ~ 185) °C Precipice: (-80 ~ 5) °C |
| Temperature recovery/toggle time [STSⅡ300-55W] | Recovery time: 2-5min Switch time: ≤10s |
| Temperature deviation [STSⅡ300-55W] | ±2.0 ℃ |
| Exposure Time [High/low temperature exposure; STSII300-55W] | High-temperature exposure:30min; low-temperature exposure:30min |
| Weight [STSⅡ300-55W] | 1500 kg |
| Maximum Current [STSⅡ300-55W] | 65 A |
| Power Supply Power [STSⅡ300-55W] | 45 kW |
| Cooling Water Flow Rate [STSⅡ300-55W] | 13 t/h |
| Materials - Boxes [STSⅡ300-55W] | SUS304 Stainless Steel Plate |
| Materials - outer boxes [STSⅡ300-55W] | Double-sided zinc-plating steel, surface treatment and electrostatic spray treatment |
| Materials - Temperature [STSⅡ300-55W] | Fibres, Khmer + polyamino hair bubble |
| Executor - High Temperature Cell [STSⅡ300-55W] | Heating machines: Importing nickel chromium alloy hair heaters, heat shock winders, axle winders during preheating |
| Executor - Low Temperature Cell [STSⅡ300-55W] | Heating machines: Imported nickel alloyed hairline chillers: tablet aluminium panels Wind machines: cooling wind machines |
| Executor -- homing basket driver [STSⅡ300-55W] | Electric screw drive moves the specimen basket vertically; motor drive(380V) |
| Executor - Refrigeration System [STSⅡ300-55W] | Piston compressor with binary cascade refrigeration; environmentally friendly refrigerants R404A and R23 |
| Control system - Touch screen + PLC [STSⅡ300-55W] | 7.0 "or 10.0", 800 × 480 resolution, Mixed output PLC |
| Control system -- mode of operation [STSⅡ300-55W] | Program Run, Time Run |
| Control system -- set [STSⅡ300-55W] | CREDIT + English, Touch input |
| Controller system - program capacity [STSⅡ300-55W] | 96 programs,3 segments each;32000 cycles can be set; program-linking functionality |
| Control system -- set range [STSⅡ300-55W] | Adjustments to the maximum range of equipment performance ± 5.0°C |
| Control system - display resolution [STSⅡ300-55W] | Temperature: 0.1°C, time:s |
| Controller system -- sensors [STSⅡ300-55W] | PT100 (Pilpium Retardation) |
| Controller system - control method [STSⅡ300-55W] | Cold-temperature balance + anti-saturation PID + self-regulating |
| Control system - Curve record [STSⅡ300-55W] | Have electrical data preservation capability, which allows slide viewing and mapping of data on screen |
| Control system -- additional function [STSⅡ300-55W] | The alarm will pop up the cause of the alarm, the time switch, power outage protection, user access. |
| Control system -- communication function [STSⅡ300-55W] | Support for communication, including RS485, LAN (web portal), GPRS (cell phone), for remote monitoring, data collection: IBM PC compatible, memory above PII CPU, 128M, CREDIT operating system |
| Controller system -- data acquisition [STSⅡ300-55W] | 1. USB supports storage of3 months of curve data and download of historical curves/data.2. Large built-in storage replaces a recorder or PC storage:3 months of continuous24-hour data at1-minute sampling. USB-drive export of selected historical times produces CSV files.3. Optional PC connection uses monitoring software to record data/display curves and enables the PC to serve as a remote-monitoring terminal. |
| Compressed Air [STSⅡ300-55W] | Pressure: 0.5 ~ 0.7 MPa flow: 0.1 cubics |
| Cold water. [STSⅡ300-55W] | Water pressure: 0.25 ~ 0.4 MPa Water temperature: ≤30°C |
| Power (V)/ [STSⅡ300-55W] | AC voltage 380V±38V; frequency 50Hz±0.5Hz; three-phase four-wire + protective grounding |
| Security devices [STSⅡ300-55W] | Fault switches, electrics, compressors, sequences, super-temperature protections. |
| Volume [STSⅡ60-65W] | 60 L |
| Box size (mm)-W [STSⅡ60-65W] | 400 mm |
| Box size (mm)-H [STSⅡ60-65W] | 370 mm |
| Box size (mm)-D [STSⅡ60-65W] | 430 mm |
| Outer box size (mm)-W [STSⅡ60-65W] | 860 mm |
| Outer box size (mm)-H [STSⅡ60-65W] | 2000 mm |
| Outer box dimensions (mm)-D [STSⅡ60-65W] | 2050 mm |
| Maximum sample weight [STSⅡ60-65W] | 20 kg |
| Test Method [STSⅡ60-65W] | Scandles in test area up or down |
| Preheat pre-cold temperature [STSⅡ60-65W] | Preheat: (60 ~ 185) °C Precipice: (-80 ~ 5) °C |
| Temperature recovery/toggle time [STSⅡ60-65W] | Recovery time: 2-5min Switch time: ≤10s |
| Temperature deviation [STSⅡ60-65W] | ±2.0 ℃ |
| Exposure Time [High/low temperature exposure; STSII60-65W] | High-temperature exposure:30min; low-temperature exposure:30min |
| Weight [STSⅡ60-65W] | 950 kg |
| Maximum Current [STSⅡ60-65W] | 47 A |
| Power Supply Power [STSⅡ60-65W] | 26 kW |
| Cooling Water Flow Rate [STSⅡ60-65W] | 9 t/h |
| Materials - Boxes [STSⅡ60-65W] | SUS304 Stainless Steel Plate |
| Materials - outer boxes [STSⅡ60-65W] | Double-sided zinc-plating steel, surface treatment and electrostatic spray treatment |
| Materials - Temperature [STSⅡ60-65W] | Fibres, Khmer + polyamino hair bubble |
| Executor - High Temperature Cell [STSⅡ60-65W] | Heating machines: Importing nickel chromium alloy hair heaters, heat shock winders, axle winders during preheating |
| Executor - Low Temperature Cell [STSⅡ60-65W] | Heating machines: Imported nickel alloyed hairline chillers: tablet aluminium panels Wind machines: cooling wind machines |
| Executor -- homing basket driver [STSⅡ60-65W] | Electric screw drive moves the specimen basket vertically; motor drive(380V) |
| Executor - Refrigeration System [STSⅡ60-65W] | Piston compressor with binary cascade refrigeration; environmentally friendly refrigerants R404A and R23 |
| Control system - Touch screen + PLC [STSⅡ60-65W] | 7.0 "or 10.0", 800 × 480 resolution, Mixed output PLC |
| Control system -- mode of operation [STSⅡ60-65W] | Program Run, Time Run |
| Control system -- set [STSⅡ60-65W] | CREDIT + English, Touch input |
| Controller system - program capacity [STSⅡ60-65W] | 96 programs,3 segments each;32000 cycles can be set; program-linking functionality |
| Control system -- set range [STSⅡ60-65W] | Adjustments to the maximum range of equipment performance ± 5.0°C |
| Control system - display resolution [STSⅡ60-65W] | Temperature: 0.1°C, time:s |
| Controller system -- sensors [STSⅡ60-65W] | PT100 (Pilpium Retardation) |
| Controller system - control method [STSⅡ60-65W] | Cold-temperature balance + anti-saturation PID + self-regulating |
| Control system - Curve record [STSⅡ60-65W] | Have electrical data preservation capability, which allows slide viewing and mapping of data on screen |
| Control system -- additional function [STSⅡ60-65W] | The alarm will pop up the cause of the alarm, the time switch, power outage protection, user access. |
| Control system -- communication function [STSⅡ60-65W] | Support for communication, including RS485, LAN (web portal), GPRS (cell phone), for remote monitoring, data collection: IBM PC compatible, memory above PII CPU, 128M, CREDIT operating system |
| Controller system -- data acquisition [STSⅡ60-65W] | 1. USB supports storage of3 months of curve data and download of historical curves/data.2. Large built-in storage replaces a recorder or PC storage:3 months of continuous24-hour data at1-minute sampling. USB-drive export of selected historical times produces CSV files.3. Optional PC connection uses monitoring software to record data/display curves and enables the PC to serve as a remote-monitoring terminal. |
| Compressed Air [STSⅡ60-65W] | Pressure: 0.5 ~ 0.7 MPa flow: 0.1 cubics |
| Cold water. [STSⅡ60-65W] | Water pressure: 0.25 ~ 0.4 MPa Water temperature: ≤30°C |
| Power (V)/ [STSⅡ60-65W] | AC voltage 380V±38V; frequency 50Hz±0.5Hz; three-phase four-wire + protective grounding |
| Security devices [STSⅡ60-65W] | Fault switches, electrics, compressors, sequences, super-temperature protections. |
| Volume [STSⅡ125-65W] | 125 L |
| Box size (mm)-W [STSⅡ125-65W] | 470 mm |
| Box size (mm)-H [STSⅡ125-65W] | 410 mm |
| Box size (mm)-D [STSⅡ125-65W] | 650 mm |
| Outer box size (mm)-W [STSⅡ125-65W] | 875 mm |
| Outer box size (mm)-H [STSⅡ125-65W] | 2000 mm |
| Outer box dimensions (mm)-D [STSⅡ125-65W] | 2250 mm |
| Maximum sample weight [STSⅡ125-65W] | 50 kg |
| Test Method [STSⅡ125-65W] | Scandles in test area up or down |
| Preheat pre-cold temperature [STSⅡ125-65W] | Preheat: (60 ~ 185) °C Precipice: (-80 ~ 5) °C |
| Temperature recovery/toggle time [STSⅡ125-65W] | Recovery time: 2-5min Switch time: ≤10s |
| Temperature deviation [STSⅡ125-65W] | ±2.0 ℃ |
| Exposure Time [High/low temperature exposure; STSII125-65W] | High-temperature exposure:30min; low-temperature exposure:30min |
| Weight [STSⅡ125-65W] | 1100 kg |
| Maximum Current [STSⅡ125-65W] | 47 A |
| Power Supply Power [STSⅡ125-65W] | 26 kW |
| Cooling Water Flow Rate [STSⅡ125-65W] | 10 t/h |
| Materials - Boxes [STSⅡ125-65W] | SUS304 Stainless Steel Plate |
| Materials - outer boxes [STSⅡ125-65W] | Double-sided zinc-plating steel, surface treatment and electrostatic spray treatment |
| Materials - Temperature [STSⅡ125-65W] | Fibres, Khmer + polyamino hair bubble |
| Executor - High Temperature Cell [STSⅡ125-65W] | Heating machines: Importing nickel chromium alloy hair heaters, heat shock winders, axle winders during preheating |
| Executor - Low Temperature Cell [STSⅡ125-65W] | Heating machines: Imported nickel alloyed hairline chillers: tablet aluminium panels Wind machines: cooling wind machines |
| Executor -- homing basket driver [STSⅡ125-65W] | Electric screw drive moves the specimen basket vertically; motor drive(380V) |
| Executor - Refrigeration System [STSⅡ125-65W] | Piston compressor with binary cascade refrigeration; environmentally friendly refrigerants R404A and R23 |
| Control system - Touch screen + PLC [STSⅡ125-65W] | 7.0 "or 10.0", 800 × 480 resolution, Mixed output PLC |
| Control system -- mode of operation [STSⅡ125-65W] | Program Run, Time Run |
| Control system -- set [STSⅡ125-65W] | CREDIT + English, Touch input |
| Controller system - program capacity [STSⅡ125-65W] | 96 programs,3 segments each;32000 cycles can be set; program-linking functionality |
| Control system -- set range [STSⅡ125-65W] | Adjustments to the maximum range of equipment performance ± 5.0°C |
| Control system - display resolution [STSⅡ125-65W] | Temperature: 0.1°C, time:s |
| Controller system -- sensors [STSⅡ125-65W] | PT100 (Pilpium Retardation) |
| Controller system - control method [STSⅡ125-65W] | Cold-temperature balance + anti-saturation PID + self-regulating |
| Control system - Curve record [STSⅡ125-65W] | Have electrical data preservation capability, which allows slide viewing and mapping of data on screen |
| Control system -- additional function [STSⅡ125-65W] | The alarm will pop up the cause of the alarm, the time switch, power outage protection, user access. |
| Control system -- communication function [STSⅡ125-65W] | Support for communication, including RS485, LAN (web portal), GPRS (cell phone), for remote monitoring, data collection: IBM PC compatible, memory above PII CPU, 128M, CREDIT operating system |
| Controller system -- data acquisition [STSⅡ125-65W] | 1. USB supports storage of3 months of curve data and download of historical curves/data.2. Large built-in storage replaces a recorder or PC storage:3 months of continuous24-hour data at1-minute sampling. USB-drive export of selected historical times produces CSV files.3. Optional PC connection uses monitoring software to record data/display curves and enables the PC to serve as a remote-monitoring terminal. |
| Compressed Air [STSⅡ125-65W] | Pressure: 0.5 ~ 0.7 MPa flow: 0.1 cubics |
| Cold water. [STSⅡ125-65W] | Water pressure: 0.25 ~ 0.4 MPa Water temperature: ≤30°C |
| Power (V)/ [STSⅡ125-65W] | AC voltage 380V±38V; frequency 50Hz±0.5Hz; three-phase four-wire + protective grounding |
| Security devices [STSⅡ125-65W] | Fault switches, electrics, compressors, sequences, super-temperature protections. |
| Volume [STSⅡ200-65W] | 200 L |
| Box size (mm)-W [STSⅡ200-65W] | 770 mm |
| Box size (mm)-H [STSⅡ200-65W] | 610 mm |
| Box size (mm)-D [STSⅡ200-65W] | 450 mm |
| Outer box size (mm)-W [STSⅡ200-65W] | 1190 mm |
| Outer box size (mm)-H [STSⅡ200-65W] | 2400 mm |
| Outer box dimensions (mm)-D [STSⅡ200-65W] | 2250 mm |
| Maximum sample weight [STSⅡ200-65W] | 70 kg |
| Test Method [STSⅡ200-65W] | Scandles in test area up or down |
| Preheat pre-cold temperature [STSⅡ200-65W] | Preheat: (60 ~ 185) °C Precipice: (-80 ~ 5) °C |
| Temperature recovery/toggle time [STSⅡ200-65W] | Recovery time: 2-5min Switch time: ≤10s |
| Temperature deviation [STSⅡ200-65W] | ±2.0 ℃ |
| Exposure Time [High/low temperature exposure; STSII200-65W] | High-temperature exposure:30min; low-temperature exposure:30min |
| Weight [STSⅡ200-65W] | 1500 kg |
| Maximum Current [STSⅡ200-65W] | 65 A |
| Power Supply Power [STSⅡ200-65W] | 45 kW |
| Cooling Water Flow Rate [STSⅡ200-65W] | 14 t/h |
| Materials - Boxes [STSⅡ200-65W] | SUS304 Stainless Steel Plate |
| Materials - outer boxes [STSⅡ200-65W] | Double-sided zinc-plating steel, surface treatment and electrostatic spray treatment |
| Materials - Temperature [STSⅡ200-65W] | Fibres, Khmer + polyamino hair bubble |
| Executor - High Temperature Cell [STSⅡ200-65W] | Heating machines: Importing nickel chromium alloy hair heaters, heat shock winders, axle winders during preheating |
| Executor - Low Temperature Cell [STSⅡ200-65W] | Heating machines: Imported nickel alloyed hairline chillers: tablet aluminium panels Wind machines: cooling wind machines |
| Executor -- homing basket driver [STSⅡ200-65W] | Electric screw drive moves the specimen basket vertically; motor drive(380V) |
| Executor - Refrigeration System [STSⅡ200-65W] | Piston compressor with binary cascade refrigeration; environmentally friendly refrigerants R404A and R23 |
| Control system - Touch screen + PLC [STSⅡ200-65W] | 7.0 "or 10.0", 800 × 480 resolution, Mixed output PLC |
| Control system -- mode of operation [STSⅡ200-65W] | Program Run, Time Run |
| Control system -- set [STSⅡ200-65W] | CREDIT + English, Touch input |
| Controller system - program capacity [STSⅡ200-65W] | 96 programs,3 segments each;32000 cycles can be set; program-linking functionality |
| Control system -- set range [STSⅡ200-65W] | Adjustments to the maximum range of equipment performance ± 5.0°C |
| Control system - display resolution [STSⅡ200-65W] | Temperature: 0.1°C, time:s |
| Controller system -- sensors [STSⅡ200-65W] | PT100 (Pilpium Retardation) |
| Controller system - control method [STSⅡ200-65W] | Cold-temperature balance + anti-saturation PID + self-regulating |
| Control system - Curve record [STSⅡ200-65W] | Have electrical data preservation capability, which allows slide viewing and mapping of data on screen |
| Control system -- additional function [STSⅡ200-65W] | The alarm will pop up the cause of the alarm, the time switch, power outage protection, user access. |
| Control system -- communication function [STSⅡ200-65W] | Support for communication, including RS485, LAN (web portal), GPRS (cell phone), for remote monitoring, data collection: IBM PC compatible, memory above PII CPU, 128M, CREDIT operating system |
| Controller system -- data acquisition [STSⅡ200-65W] | 1. USB supports storage of3 months of curve data and download of historical curves/data.2. Large built-in storage replaces a recorder or PC storage:3 months of continuous24-hour data at1-minute sampling. USB-drive export of selected historical times produces CSV files.3. Optional PC connection uses monitoring software to record data/display curves and enables the PC to serve as a remote-monitoring terminal. |
| Compressed Air [STSⅡ200-65W] | Pressure: 0.5 ~ 0.7 MPa flow: 0.1 cubics |
| Cold water. [STSⅡ200-65W] | Water pressure: 0.25 ~ 0.4 MPa Water temperature: ≤30°C |
| Power (V)/ [STSⅡ200-65W] | AC voltage 380V±38V; frequency 50Hz±0.5Hz; three-phase four-wire + protective grounding |
| Security devices [STSⅡ200-65W] | Fault switches, electrics, compressors, sequences, super-temperature protections. |
| Volume [STSⅡ300-65W] | 300 L |
| Box size (mm)-W [STSⅡ300-65W] | 770 mm |
| Box size (mm)-H [STSⅡ300-65W] | 610 mm |
| Box size (mm)-D [STSⅡ300-65W] | 650 mm |
| Outer box size (mm)-W [STSⅡ300-65W] | 1470 mm |
| Outer box size (mm)-H [STSⅡ300-65W] | 2200 mm |
| Outer box dimensions (mm)-D [STSⅡ300-65W] | 2500 mm |
| Maximum sample weight [STSⅡ300-65W] | 80 kg |
| Test Method [STSⅡ300-65W] | Scandles in test area up or down |
| Preheat pre-cold temperature [STSⅡ300-65W] | Preheat: (60 ~ 185) °C Precipice: (-80 ~ 5) °C |
| Temperature recovery/toggle time [STSⅡ300-65W] | Recovery time: 2-5min Switch time: ≤10s |
| Temperature deviation [STSⅡ300-65W] | ±2.0 ℃ |
| Exposure Time [High/low temperature exposure; STSII300-65W] | High-temperature exposure:30min; low-temperature exposure:30min |
| Weight [STSⅡ300-65W] | 1700 kg |
| Maximum Current [STSⅡ300-65W] | 72 A |
| Power Supply Power [STSⅡ300-65W] | 55 kW |
| Cooling Water Flow Rate [STSⅡ300-65W] | 16 t/h |
| Materials - Boxes [STSⅡ300-65W] | SUS304 Stainless Steel Plate |
| Materials - outer boxes [STSⅡ300-65W] | Double-sided zinc-plating steel, surface treatment and electrostatic spray treatment |
| Materials - Temperature [STSⅡ300-65W] | Fibres, Khmer + polyamino hair bubble |
| Executor - High Temperature Cell [STSⅡ300-65W] | Heating machines: Importing nickel chromium alloy hair heaters, heat shock winders, axle winders during preheating |
| Executor - Low Temperature Cell [STSⅡ300-65W] | Heating machines: Imported nickel alloyed hairline chillers: tablet aluminium panels Wind machines: cooling wind machines |
| Executor -- homing basket driver [STSⅡ300-65W] | Electric screw drive moves the specimen basket vertically; motor drive(380V) |
| Executor - Refrigeration System [STSⅡ300-65W] | Piston compressor with binary cascade refrigeration; environmentally friendly refrigerants R404A and R23 |
| Control system - Touch screen + PLC [STSⅡ300-65W] | 7.0 "or 10.0", 800 × 480 resolution, Mixed output PLC |
| Control system -- mode of operation [STSⅡ300-65W] | Program Run, Time Run |
| Control system -- set [STSⅡ300-65W] | CREDIT + English, Touch input |
| Controller system - program capacity [STSⅡ300-65W] | 96 programs,3 segments each;32000 cycles can be set; program-linking functionality |
| Control system -- set range [STSⅡ300-65W] | Adjustments to the maximum range of equipment performance ± 5.0°C |
| Control system - display resolution [STSⅡ300-65W] | Temperature: 0.1°C, time:s |
| Controller system -- sensors [STSⅡ300-65W] | PT100 (Pilpium Retardation) |
| Controller system - control method [STSⅡ300-65W] | Cold-temperature balance + anti-saturation PID + self-regulating |
| Control system - Curve record [STSⅡ300-65W] | Have electrical data preservation capability, which allows slide viewing and mapping of data on screen |
| Control system -- additional function [STSⅡ300-65W] | The alarm will pop up the cause of the alarm, the time switch, power outage protection, user access. |
| Control system -- communication function [STSⅡ300-65W] | Support for communication, including RS485, LAN (web portal), GPRS (cell phone), for remote monitoring, data collection: IBM PC compatible, memory above PII CPU, 128M, CREDIT operating system |
| Controller system -- data acquisition [STSⅡ300-65W] | 1. USB supports storage of3 months of curve data and download of historical curves/data.2. Large built-in storage replaces a recorder or PC storage:3 months of continuous24-hour data at1-minute sampling. USB-drive export of selected historical times produces CSV files.3. Optional PC connection uses monitoring software to record data/display curves and enables the PC to serve as a remote-monitoring terminal. |
| Compressed Air [STSⅡ300-65W] | Pressure: 0.5 ~ 0.7 MPa flow: 0.1 cubics |
| Cold water. [STSⅡ300-65W] | Water pressure: 0.25 ~ 0.4 MPa Water temperature: ≤30°C |
| Power (V)/ [STSⅡ300-65W] | AC voltage 380V±38V; frequency 50Hz±0.5Hz; three-phase four-wire + protective grounding |
| Security devices [STSⅡ300-65W] | Fault switches, electrics, compressors, sequences, super-temperature protections. |