Double-Station (Double-Sided) Glovebox Lab2000/1200/1000

Double-Station (Double-Sided) Glovebox Lab2000/1200/1000

Supplier
Etelux
Part Number
Lab2000/1200/1000
Category
Material-based Production Equipment
Origin
China

Box:3mm stainless1.4301(SUS type304),1200mm(L)x1000mm(W)x900mm(H). Front panel:8mm tempered safety glass or10mm polycarbonate,1123mm(L)x839mm(H). Glove ports:hard aluminum alloy or polyoxymethylene,220mm diameter,O-ring sealed. Butyl gloves:0.4mm or0.8mm options. Inlet/outlet filters are specified as filtering<0.3μm. Final box acceptance uses ISO10648-2:1994/EJ/T1096-1999 oxygen-content/pressure-change methods,Class1 leak-tightness<0.0005vol%/h. GP20 automatically removes H₂O/O₂ with a single regenerating purification column; GP200 dual columns are optional. Gas circulation is sealed. Working gases:N₂,Ar orHe,purity≥99.999%; regeneration uses5%-10% H₂ and the remainder working gas(purity≥99.999%). Pump options:rotary-vane with oil-mist filter/gas-ballast control,12m³/h(7cfm),described as dual-substrate,vacuum<2x10⁻³mbar,or dry pump. GP20 acceptance uses the same standards/methods but Class1<0.001vol%/h. Timed pressure-controlled gas replacement is automatic. Other oxygen analyzer:GE oxy.IQ™ Oxygen Transmitter. Moisture analyzer:acid-resistant AD-160P phosphorus-pentoxide analyzer; other:GE VeriDri™ Dew-Point Transmitter. Solvent purifier:3mm stainless1.4301/SUS304,internal220mm(Φ)x450mm(H),high-quality activated carbon. Optional side-mounted independently controlled refrigerator:-35℃,18L/32L,304 stainless tubing,five adjustable shelves,imported R404 refrigerant. Optional large-airlock heating:200℃ with±1℃ control. Listed certifications:ISO9001,CE and UL. One-year warranty,lifetime repair; consult manual danger/warning/caution provisions.

Specification Snapshot
Dimensions
1950mm×1000mm×1900mm
Request a Quote Download Datasheet
Save to Favorites Save to Favorites

Overview

Box:3mm stainless1.4301(SUS type304),1200mm(L)x1000mm(W)x900mm(H). Front panel:8mm tempered safety glass or10mm polycarbonate,1123mm(L)x839mm(H). Glove ports:hard aluminum alloy or polyoxymethylene,220mm diameter,O-ring sealed. Butyl gloves:0.4mm or0.8mm options. Inlet/outlet filters are specified as filtering<0.3μm. Final box acceptance uses ISO10648-2:1994/EJ/T1096-1999 oxygen-content/pressure-change methods,Class1 leak-tightness<0.0005vol%/h. GP20 automatically removes H₂O/O₂ with a single regenerating purification column; GP200 dual columns are optional. Gas circulation is sealed. Working gases:N₂,Ar orHe,purity≥99.999%; regeneration uses5%-10% H₂ and the remainder working gas(purity≥99.999%). Pump options:rotary-vane with oil-mist filter/gas-ballast control,12m³/h(7cfm),described as dual-substrate,vacuum<2x10⁻³mbar,or dry pump. GP20 acceptance uses the same standards/methods but Class1<0.001vol%/h. Timed pressure-controlled gas replacement is automatic. Other oxygen analyzer:GE oxy.IQ™ Oxygen Transmitter. Moisture analyzer:acid-resistant AD-160P phosphorus-pentoxide analyzer; other:GE VeriDri™ Dew-Point Transmitter. Solvent purifier:3mm stainless1.4301/SUS304,internal220mm(Φ)x450mm(H),high-quality activated carbon. Optional side-mounted independently controlled refrigerator:-35℃,18L/32L,304 stainless tubing,five adjustable shelves,imported R404 refrigerant. Optional large-airlock heating:200℃ with±1℃ control. Listed certifications:ISO9001,CE and UL. One-year warranty,lifetime repair; consult manual danger/warning/caution provisions.

Specifications

ParameterValue
Dimensions1950mm×1000mm×1900mm
Working Dimensions1200mm×1000mm×900mm
Water content< 0.1 ppm, can reach 0.01 ppm
Oxygen content< 0.1 ppm, can reach 0.01 ppm
Box leak rate≤0.001vol%/h, capable of reaching 0.0008vol%/h
Boxes - Materialsstainless steel 1.4301 (SUS type 304)
Box - thickness3 mm
Boxes - Dimensions1200mm(L) x 1000mm(W) x 900mm(H)
Box - Volume1.1 m³
Box - Front Window - Panel Selection8 mm thick, safe steel-coated glass or 10 mm thick polycarbonate (optional)
Box - Front Window - Size1123mm(L) x 839mm(H)
Boxes - Gloves - Material Selection [Options]Hard aluminium alloy or polysalm material
Boxes - Gloves Ports - caliber220 mm
Boxes - Gloves mouths - SealedO-circle seal.
Boxes - Gloves - MaterialsButyl rubber
Box - Glove - thickness selection0.4 mm or 0.8 mm (optional)
Boxes - Filters - Filter Indicators [Export and entrance filters]<0.3 μm
Boxes - LightingLED lighting is on top of the front window.
GP20 Gas purification system - purified objectH₂O and O₂
GP20 Gas purification system - structureSingle-purification column system
GP20 Gas purification system - RegenerationAutomatic regeneration
GP20 Gas purification system - Cyclical pipelineClosed gas circulation pipe
GP20 Gas purification system - use of voltageAC 230 V / 50-60 Hz, 10 A or AC 115 V / 50-60 Hz, 20 A (optional)
GP20 Gas purification system - working gasN₂、Ar 、He
GP20 Gas purification system - working gas purity [Working: N₂, Ar, He]≥99.999 %
GP20 Gas purification system - re-asymmetric - H₂ ratio [And get angry.]5%—10%
GP20 Gas purification system - re-emergence - residual compositionThe rest is for work.
GP20 Gas purification system - re-emergence - residual work-gas purity [The rest is for work.]≥99.999 %
GP20 Gas purification system - vacuum pump - typeSlipple vacuum pump
GP20 Gas purification system -- spiral vacuum pump -- attachment [Slipple vacuum pump]Oil Mist Filter
GP20 Gas purification system -- spiral vacuum pump -- control of gas town [Slipple vacuum pump]Airborne control.
GP20 Gas purification system - spiral vacuum pump - flow [Slipple vacuum pump]12 m³/h (7 cfm)
GP20 Gas purification system - spiral vacuum pump - structure [Slipple vacuum pump]Double Base
GP20 Gas purification system - Slipper vacuum pump - vacuum [Slipple vacuum pump]< 2 x 10⁻³ mbar
GP20 Gas purification system - Circulatory unit - TypeOil-free high-speed wind
GP20 Gas purification system - Circulatory unit - Wind volume80 m³/h
GP20 Gas purification system - valveKF40 High Vacuum Valve
Transition class -- large transition class -- materialsstainless steel type 304 (1.4301)
Transition class -- large transition class -- thickness3 mm
Transition class -- large transition class -- size selectionφ360 mmx600mm(L) or φ390mmx600mm(L) (optional)
Transition class -- large transition module -- vacuum< 1 x 10⁻² mbar
Transition class -- small transition module -- materialsstainless steel type 304 (1.4301)
Transition class - small transition module - thickness2 mm
Transition class -- small transition class -- sizeφ150mm x 330mm(L)
Transition class -- small transition module -- vacuum< 1 x 10⁻² mbar
Analyzer-oxygen analyser-modelAF-360Z
Analyzers - oxygen analysers - dimensions [AF-360Z]205 mm(L) x 80 mm(W) x 60 mm(H)
Analyzers - oxygen analysers - range measurement [AF-360Z]0-1000 ppm
Analyzer - Hydrological analyser - ModelAD-160P
Analyzers - hydrometric analysers - typesHydrophosphorus dioxide water analyser (acid anti-acid)
Analyzer-water analyser-size [AD-160P]205 mm(L) x 80 mm(W) x 60 mm(H)
Analyzers - hydrometric analysers - range of measurements [AD-160P]0-500 ppm
Solvent purification systems - materialsstainless steel 1.4301 (SUS type 304)
Solvent purification system - thickness3 mm
Solvent purification systems - internal dimensions220mm(Φ) x 450mm(H)
Solvent purification system - mediaHigh-quality activated carbon
Refrigerator-control system [Selecting Devices]Independent control system
Refrigerator - Integration Position [Selecting Devices]Integration on the sideboard of the box.
Refrigerator - Temperature [Selecting Devices]-35 ℃
Refrigerator - Volume Selection [Selecting Devices]18L or 32L options.
Refrigerator - main material [Selecting Devices]304 stainless steel pipes
Refrigerator - Sewer [Selecting Devices]5-Story variable ionosphere
Refrigerator - Refrigerant [Selecting Devices]R404 Environmentally friendly refrigerant
Transition class -- large transition module -- selection of heating temperature [Selection equipment; large transition module]200 ℃
Transition module - Large Transition module - Selection with heat control [Selection equipment; large transition module]±1 ℃
Package Dimensions (W×D×H)2100mm×1350mm×2100mm
Weight630 KG

Applications

For aviation, space, engines, medical, motor, electronic, moulds, scientific research institutes

Key Features

Etelux patented double-O-ring flange window — features and benefits (patent CN104260114B). A thick, one-piece stainless-steel plate is laser-cut into a strong rectangular ring resistant to impact, compression and deformation. The complete flange window and annular seal grooves are machined in one setup on a large gantry machining center. Double dovetail grooves provide sealing support surfaces and groove bottoms with flatness <0.05mm/m. Continuous cooled welding joins the flange window to the enclosure, with full nondestructive weld inspection and no leakage at the welds. Two seamless annular O-rings fit into integral grooves, using vacuum isolation between the two seals to block inward diffusion of airborne H₂0, 0₂ and N₂ molecules and outward diffusion of toxic molecules. This provides a leak-free sealing effect, with enclosure leakage <0.0005vol%/h.

Datasheet

Please provide your email to download the datasheet.

Your name
Email Address

Invalid email format. Please try again.

Send Request

Supplier Information

Et
Etelux
View Supplier →
Etelux Inert Gas System (Beijing) Co., Ltd. was established in February 1998, introducing and absorbing European and American technologies to develop inert gas protection equipment, used for glove boxes in science and technology education, university research, lithium battery industry, laser industry, etc., filling the history of long-term dependence on imports in China, greatly reducing procurement costs, and deeply trusted by users. We have always adhered to the business philosophy of "customer first, excellence" and the principle of "customer first" to provide quality services to our customers. We bravely shoulder the responsibilities of the times and social missions, provide customers with higher value service experiences, focus on research and development, continuous innovation, and maintain a leading position in the glove box industry. Etelux Inert Gas System (Beijing) Co., Ltd. has a registered capital of 50 million yuan and owns two major production bases covering an area of more than 10,000 square meters. The company produces various products such as biochemical experimental glove boxes, lithium battery glove boxes, glove boxes for special lamp production, solvent filtration systems, solvent purification systems, gas purification systems, etc. They have been adopted by more than 1,000 customers in aerospace, weapons, military, power supply, biochemistry, physics, metallurgy, electronics, materials and other fields. In recent years, more than 5,000 sets of various equipment not only cover various provinces and regions in China, but also cover Europe and the United States. Its service network has covered major cities in China, and has sales and after-sales service institutions in Beijing, Shanghai, Wuhan, and Guangzhou.

Request a Quote

Our team responds within 24–48 hours
Double-Station (Double-Sided) Glovebox Lab2000/1200/1000
Etelux · Material-based Production Equipment
Direct from Manufacturer
Your inquiry will be sent directly to the manufacturer
Photonics Source Platform
We handles the inquiry on your behalf
Your information is protected and will never be shared without consent.
Contact Us

Loading...

GetExperimental Plan

Name

Phone

+86

Organization

Use Case

AI Parametric Selection
Smart Match · Precise Recs
Enter Specifications
AI Smart Matching
Get Best Matches
Skip Manual Comparison
Find Best Solutions Fast
Select Now →