Double-Station (Single-Sided) Glovebox Lab2000/1800/750

Double-Station (Single-Sided) Glovebox Lab2000/1800/750

Supplier
Etelux
Part Number
Lab2000/1800/750
Category
Material-based Production Equipment
Origin
China

Chamber: 1.4301 stainless steel (SUS type 304), 3 mm thick; dimensions 1800 mm (L) × 750 mm (W) × 900 mm (H). Front window: either 8 mm-thick safety-tempered glass or 10 mm-thick polycarbonate; 1723 mm (L) × 839 mm (H). Glove ports: hard aluminum alloy or polyoxymethylene, selectable; 220 mm diameter with O-ring sealing. Gloves: butyl rubber, with selectable 0.4 mm or 0.8 mm thickness. Inlet and outlet filters: filtration <0.3 μm. LED lighting is located above the top of the front window. Chamber leakage testing: oxygen-content and pressure-change methods under ISO 10648-2:1994 / EJ/T 1096-1999, Containment enclosures—Part 2: Classification according to leak tightness and associated checking methods; final acceptance according to Class 1 leak tightness <0.0005 vol%/h. GP20 gas purification: automatic H₂O and O₂ removal, a single purification column with automatic regeneration, optionally a GP200 dual-column system; sealed gas-circulation piping. Power supply options: AC 230 V / 50–60 Hz, 10 A, or AC 115 V / 50–60 Hz, 20 A. Working gases: N₂, Ar or He, purity ≥99.999%. Regeneration gas: 5%–10% H₂, with the balance being working gas of purity ≥99.999%. Vacuum pump: rotary-vane pump with oil-mist filter and gas-ballast control; flow 12 m³/h (7 cfm), described as dual-substrate; vacuum <2 × 10⁻³ mbar, or an optional dry pump. Circulation unit: oil-free high-speed blower, airflow 80 m³/h. Valves: KF40 high-vacuum valves. GP20 leakage testing: oxygen-content and pressure-change methods under ISO 10648-2:1994 / EJ/T 1096-1999, with final acceptance to Class 1 leak tightness <0.001 vol%/h. Large antechamber: type 304 (1.4301) stainless steel, 3 mm thick. Purging system: after the corresponding duration and pressure are set, the system automatically replaces the chamber gas. Oxygen analyzer: AF-360Z; alternative GE oxy.IQ™ Oxygen Transmitter. Moisture analyzer: acid-resistant AD-160P phosphorus pentoxide instrument; alternative GE VeriDri™ Dew-Point Transmitter. Solvent purification: 1.4301 stainless steel (SUS type 304), 3 mm thick; internal dimensions 220 mm (Φ) × 450 mm (H), with high-quality activated carbon. Optional refrigerator: independently controlled and integrated into the chamber side panel; -35°C, selectable 18 L or 32 L capacity, 304 stainless-steel tubular main structure, five adjustable shelf levels and imported R404 refrigerant described as environmentally friendly. Optional heated antechamber: heating system in the large antechamber, 200°C with temperature control ±1°C. Product certifications stated: ISO9001, CE and UL. Warranty: one year, with lifetime repair service. Application precautions: consult the Danger, Warning, Caution and related sections of the instruction manual.

Specification Snapshot
Dimensions
2550mm×750mm×1900mm
Request a Quote Download Datasheet
Save to Favorites Save to Favorites

Overview

Chamber: 1.4301 stainless steel (SUS type 304), 3 mm thick; dimensions 1800 mm (L) × 750 mm (W) × 900 mm (H). Front window: either 8 mm-thick safety-tempered glass or 10 mm-thick polycarbonate; 1723 mm (L) × 839 mm (H). Glove ports: hard aluminum alloy or polyoxymethylene, selectable; 220 mm diameter with O-ring sealing. Gloves: butyl rubber, with selectable 0.4 mm or 0.8 mm thickness. Inlet and outlet filters: filtration <0.3 μm. LED lighting is located above the top of the front window. Chamber leakage testing: oxygen-content and pressure-change methods under ISO 10648-2:1994 / EJ/T 1096-1999, Containment enclosures—Part 2: Classification according to leak tightness and associated checking methods; final acceptance according to Class 1 leak tightness <0.0005 vol%/h. GP20 gas purification: automatic H₂O and O₂ removal, a single purification column with automatic regeneration, optionally a GP200 dual-column system; sealed gas-circulation piping. Power supply options: AC 230 V / 50–60 Hz, 10 A, or AC 115 V / 50–60 Hz, 20 A. Working gases: N₂, Ar or He, purity ≥99.999%. Regeneration gas: 5%–10% H₂, with the balance being working gas of purity ≥99.999%. Vacuum pump: rotary-vane pump with oil-mist filter and gas-ballast control; flow 12 m³/h (7 cfm), described as dual-substrate; vacuum <2 × 10⁻³ mbar, or an optional dry pump. Circulation unit: oil-free high-speed blower, airflow 80 m³/h. Valves: KF40 high-vacuum valves. GP20 leakage testing: oxygen-content and pressure-change methods under ISO 10648-2:1994 / EJ/T 1096-1999, with final acceptance to Class 1 leak tightness <0.001 vol%/h. Large antechamber: type 304 (1.4301) stainless steel, 3 mm thick. Purging system: after the corresponding duration and pressure are set, the system automatically replaces the chamber gas. Oxygen analyzer: AF-360Z; alternative GE oxy.IQ™ Oxygen Transmitter. Moisture analyzer: acid-resistant AD-160P phosphorus pentoxide instrument; alternative GE VeriDri™ Dew-Point Transmitter. Solvent purification: 1.4301 stainless steel (SUS type 304), 3 mm thick; internal dimensions 220 mm (Φ) × 450 mm (H), with high-quality activated carbon. Optional refrigerator: independently controlled and integrated into the chamber side panel; -35°C, selectable 18 L or 32 L capacity, 304 stainless-steel tubular main structure, five adjustable shelf levels and imported R404 refrigerant described as environmentally friendly. Optional heated antechamber: heating system in the large antechamber, 200°C with temperature control ±1°C. Product certifications stated: ISO9001, CE and UL. Warranty: one year, with lifetime repair service. Application precautions: consult the Danger, Warning, Caution and related sections of the instruction manual.

Specifications

ParameterValue
Boxes - Materialsstainless steel 1.4301 (SUS type 304)
Box - thickness3 mm
Boxes - Dimensions1800mm(L) x 750mm(W) x 900mm(H)
Box - Volume1.2 m³
Box - Front Window - Panel [Options]8 mm thick, safe steel-coated glass or 10 mm thick polycarbonate (optional)
Box - Front Window - Size1723mm(L) x 839mm(H)
Boxes - Gloves - Materials [Options]Hard aluminium alloy or polymether formaldehyde material (optional)
Boxes - Gloves Ports - caliber220 mm
Boxes - Gloves mouths - SealedO-circle seal.
Boxes - Gloves - MaterialsButyl rubber
Box - Glove - Thickness [Options]0.4 mm or 0.8 mm (optional)
Box - FilterOutlet and inlet filters, filtration <0.3μm
Boxes - LightingLED lighting is on top of the front window.
Boxes - leakage rate [The leakage is based on ISO 10648-2: 1994 / EJ/T 1096-1999 Seal-part II: Sealed classification and associated test methods for oxygen and pressure change testing of the container, according to the first-level sealing]< 0.0005 vol%/h
GP20 Gas purification system - use of voltage [Options]AC 230 V / 50-60 Hz, 10 A or AC 115 V / 50-60 Hz, 20 A (optional)
GP20 Gas purification system - working gas - working gas [Purity ≥99.999%]N₂, Ar, He (purity ≥99.999%)
GP20 Gas purification system - working gas - re-emergence [The balance is working gas (purity ≥99.999%)]H₂ 5%—10%, with the balance being working gas (purity ≥99.999%)
GP20 Gas purification system - Vacuum pump - SpecificationSpiral vacuum pump, with oil fog filters, gas town control
GP20 Gas purification system - Vacuum pump - Flow12 m³/h (7 cfm)
GP20 Gas purification system - Vacuum pump - Vacuity< 2 x 10⁻³mbar
GP20 Gas purification system - Circulatory unit - Wind volume80 m³/h
GP20 Gas purification system - valveKF40 High Vacuum Valve
GP20 Gas purification system - leakage rate [The leakage is based on ISO 10648-2: 1994/EJ/T 1096-1999 Seal-part II: Sealed classification and associated test methods for oxygen and pressure change testing of the container, according to level 1 sealing]< 0.001 vol%/h
Transition class -- large transition class -- materialsstainless steel type 304 (1.4301)
Transition class -- large transition class -- thickness3 mm
Transition class -- large transition class -- size [Options]φ360 mmx600mm(L) or φ390mmx600mm(L) (optional)
Transition class -- large transition module -- vacuum< 1 x 10⁻² mbar
Transition class -- small transition module -- materialsstainless steel type 304 (1.4301)
Transition class - small transition module - thickness2 mm
Transition class -- small transition class -- sizeφ150mm x 330mm(L)
Transition class -- small transition module -- vacuum< 1 x 10⁻² mbar
Analyzers - oxygen analysers - dimensions [AF-360Z]205 mm(L) x 80 mm(W) x 60 mm(H)
Analyzers - oxygen analysers - range measurement [AF-360Z]0-1000 ppm
Analyzer-water analyser-size [AD-160P Dioxidated phosphorus water analyser (acid anti-acid)]205 mm(L) x 80 mm(W) x 60 mm(H)
Analyzers - hydrometric analysers - range of measurements [AD-160P Dioxidated phosphorus water analyser (acid anti-acid)]0-500 ppm
Solvent purification systems - materialsstainless steel 1.4301 (SUS type 304)
Solvent purification system - thickness3 mm
Solvent purification systems - internal dimensions220mm(Φ) x 450mm(H)
Selective equipment - refrigerator - temperature-35 ℃
Selective equipment - refrigerator - volume [Optional]18L or 32L options.
Selector equipment - refrigerator - main304 stainless steel pipes
Selective equipment - refrigerator - compartment5-Story variable ionosphere
Selection equipment - refrigerator - refrigerantR404 Environmentally friendly refrigerant, original import
Selection equipment - heating module - temperature [- Big transition.]200 ℃
Selection equipment - Heating module - temperature control [- Big transition.]±1 ℃
Package Dimensions (W×D×H)2700mm×1100mm×2100mm
Weight650 KG
Dimensions2550mm×750mm×1900mm
Working Dimensions1800mm×750mm×900mm
Water content< 0.1 ppm, can reach 0.01 ppm
Oxygen content< 0.1 ppm, can reach 0.01 ppm
Box leak rate≤0.001vol%/h, capable of reaching 0.0008vol%/h

Applications

For aviation, space, engines, medical, motor, electronic, moulds, scientific research institutes

Key Features

Etelux patented double-O-ring flange window — features and benefits (patent CN104260114B). A thick, one-piece stainless-steel plate is laser-cut into a strong rectangular ring resistant to impact, compression and deformation. The complete flange window and annular seal grooves are machined in one setup on a large gantry machining center. Double dovetail grooves provide sealing support surfaces and groove bottoms with flatness <0.05mm/m. Continuous cooled welding joins the flange window to the enclosure, with full nondestructive weld inspection and no leakage at the welds. Two seamless annular O-rings fit into integral grooves, using vacuum isolation between the two seals to block inward diffusion of airborne H₂0, 0₂ and N₂ molecules and outward diffusion of toxic molecules. This provides a leak-free sealing effect, with enclosure leakage <0.0005vol%/h.

Datasheet

Please provide your email to download the datasheet.

Your name
Email Address

Invalid email format. Please try again.

Send Request

Supplier Information

Et
Etelux
View Supplier →
Etelux Inert Gas System (Beijing) Co., Ltd. was established in February 1998, introducing and absorbing European and American technologies to develop inert gas protection equipment, used for glove boxes in science and technology education, university research, lithium battery industry, laser industry, etc., filling the history of long-term dependence on imports in China, greatly reducing procurement costs, and deeply trusted by users. We have always adhered to the business philosophy of "customer first, excellence" and the principle of "customer first" to provide quality services to our customers. We bravely shoulder the responsibilities of the times and social missions, provide customers with higher value service experiences, focus on research and development, continuous innovation, and maintain a leading position in the glove box industry. Etelux Inert Gas System (Beijing) Co., Ltd. has a registered capital of 50 million yuan and owns two major production bases covering an area of more than 10,000 square meters. The company produces various products such as biochemical experimental glove boxes, lithium battery glove boxes, glove boxes for special lamp production, solvent filtration systems, solvent purification systems, gas purification systems, etc. They have been adopted by more than 1,000 customers in aerospace, weapons, military, power supply, biochemistry, physics, metallurgy, electronics, materials and other fields. In recent years, more than 5,000 sets of various equipment not only cover various provinces and regions in China, but also cover Europe and the United States. Its service network has covered major cities in China, and has sales and after-sales service institutions in Beijing, Shanghai, Wuhan, and Guangzhou.

Request a Quote

Our team responds within 24–48 hours
Double-Station (Single-Sided) Glovebox Lab2000/1800/750
Etelux · Material-based Production Equipment
Direct from Manufacturer
Your inquiry will be sent directly to the manufacturer
Photonics Source Platform
We handles the inquiry on your behalf
Your information is protected and will never be shared without consent.
Contact Us

Loading...

GetExperimental Plan

Name

Phone

+86

Organization

Use Case

AI Parametric Selection
Smart Match · Precise Recs
Enter Specifications
AI Smart Matching
Get Best Matches
Skip Manual Comparison
Find Best Solutions Fast
Select Now →