OC Scanner Terahertz Spectrometer and Time-Domain Pulsed Imaging System

OC Scanner Terahertz Spectrometer and Time-Domain Pulsed Imaging System

Supplier
Hr-eo
Category
Terahertz Imaging
Origin
China

The source describes the OCScanner as the world’s first terahertz-camera time-domain pulsed imaging system. It uses broadband organic-crystal terahertz emitters and detectors,with industrial-standard maintenance-free24/7operation and high stability. Easy-to-use software provides time-domain waveforms and spectral analysis. Optional analysis tools support material-composition analysis and imaging; an optionalRigiterahertz camera provides imaging detection.

Request a Quote Download Datasheet
Save to Favorites Save to Favorites

Overview

The source describes the OCScanner as the world’s first terahertz-camera time-domain pulsed imaging system. It uses broadband organic-crystal terahertz emitters and detectors,with industrial-standard maintenance-free24/7operation and high stability. Easy-to-use software provides time-domain waveforms and spectral analysis. Optional analysis tools support material-composition analysis and imaging; an optionalRigiterahertz camera provides imaging detection.

Specifications

ParameterValue
1200-1600nm,50fs(FWHM)—Source Column “Model1”—Repetition Rate< 3 KHz
1200-1600nm,50fs(FWHM)—Source Column “Model1”400 μJ (1KHz)
1200-1600nm,50fs(FWHM)—Source Column “Model1”—Output Terahertz Energy> 8 μJ
Source-Labeled THz Peak Power [1200-1600nm,50fs(FWHM);Source Column “Model1”]> 22 MV/cm
1200-1600nm,50fs(FWHM)—Source Column “Model2”—Repetition Rate< 3 KHz
1200-1600nm,50fs(FWHM)—Source Column “Model2”2 mJ (1KHz)
1200-1600nm,50fs(FWHM)—Source Column “Model2”—Output Terahertz Energy> 40 μJ
Source-Labeled THz Peak Power [1200-1600nm,50fs(FWHM);Source Column “Model2”]> 50 MV/cm
1200-1600nm,50fs(FWHM)—Source Column “Model3”—Repetition Rate< 3 KHz
1200-1600nm,50fs(FWHM)—Source Column “Model3”10 mJ (1KHz)
1200-1600nm,50fs(FWHM)—Source Column “Model3”—Output Terahertz Energy> 200 μJ
Source-Labeled THz Peak Power [1200-1600nm,50fs(FWHM);Source Column “Model3”]> 120 MV/cm
800 nm, 80fs(FWHM)—Source Column “Model1”—Repetition Rate1 KHz
800 nm, 80fs(FWHM)—Source Column “Model1”400 μJ
800 nm, 80fs(FWHM)—Source Column “Model1”—Output Terahertz Energy> 0.4 μJ
Source-Labeled THz Peak Power [800 nm, 80fs(FWHM);Source Column “Model1”]> 0.4 MV/cm
800 nm, 80fs(FWHM)—Source Column “Model2”—Repetition Rate1 KHz
800 nm, 80fs(FWHM)—Source Column “Model2”2 mJ
800 nm, 80fs(FWHM)—Source Column “Model2”—Output Terahertz Energy> 2 μJ
Source-Labeled THz Peak Power [800 nm, 80fs(FWHM);Source Column “Model2”]> 1 MV/cm
800 nm, 80fs(FWHM)—Source Column “Model3”—Repetition Rate1 KHz
800 nm, 80fs(FWHM)—Source Column “Model3”10 mJ
800 nm, 80fs(FWHM)—Source Column “Model3”—Output Terahertz Energy> 10 μJ
Source-Labeled THz Peak Power [800 nm, 80fs(FWHM);Source Column “Model3”]> 3 MV/cm
800 nm, 80fs(FWHM)—Source Column “Model4”—Repetition Rate100 Hz
800 nm, 80fs(FWHM)—Source Column “Model4”2 mJ
800 nm, 80fs(FWHM)—Source Column “Model4”—Output Terahertz Energy> 4 μJ
Source-Labeled THz Peak Power [800 nm, 80fs(FWHM);Source Column “Model4”]> 2 MV/cm
800 nm, 80fs(FWHM)—Source Column “Model5”—Repetition Rate100 Hz
800 nm, 80fs(FWHM)—Source Column “Model5”2 mJ
800 nm, 80fs(FWHM)—Source Column “Model5”—Output Terahertz Energy> 40 μJ
Source-Labeled THz Peak Power [800 nm, 80fs(FWHM);Source Column “Model5”]> 6 MV/cm
Laser Parameters—Wavelength1550 nm
Source-Labeled Laser Pulse Duration>120 mW
Laser Parameters—Pulse Repetition Rate40-100 MHz
Terahertz Signal Parameters—Peak Frequency3 - 4 THz
Terahertz Signal Parameters—Bandwidth0.1 - 15 THz
Terahertz Signal Parameters—Peak Dynamic Range> 60 dB
Terahertz Signal Parameters—Time-Domain Signal Scan Range> 300 ps

Applications

Material-composition analysis and imaging.

Datasheet

Please provide your email to download the datasheet.

Your name
Email Address

Invalid email format. Please try again.

Send Request

Supplier Information

Huirui Optoelectronics Technology (Beijing) Co., Ltd. was founded in 2014 by researchers from Beijing Institute of Technology, Capital Normal University, Tsinghua University and other universities. The team members have more than ten years of research foundation in high-precision optical component design and optical system development, and fully master cutting-edge advanced technologies in the fields of optical detection, life sciences and medical health. They are in a leading position in the industry in theoretical research, crystal materials, processing technology, etc. The company started focusing on terahertz optics research, continuously expanded its research fields, and has now become an industry leader committed to developing high-end precision optical components.

Request a Quote

Our team responds within 24–48 hours
OC Scanner Terahertz Spectrometer and Time-Domain Pulsed Imaging System
Hr-eo · Terahertz Imaging
Direct from Manufacturer
Your inquiry will be sent directly to the manufacturer
Photonics Source Platform
We handles the inquiry on your behalf
Your information is protected and will never be shared without consent.
Contact Us

Loading...

GetExperimental Plan

Name

Phone

+86

Organization

Use Case

AI Parametric Selection
Smart Match · Precise Recs
Enter Specifications
AI Smart Matching
Get Best Matches
Skip Manual Comparison
Find Best Solutions Fast
Select Now →