Plug-in OLP Optical Line Protection System
The OLP optical line protection subsystem launched by Shenzhen ISEELINK communication Technology Co., Ltd.is based on the advanced development of optical switch technology. It’s an automatic monitoring and protection system independent of communication transmission system and completely based on the physical link of optical cable. The system can automatically switch the signal to the optical fiber of the protection path when performance deterioration or blocking of work path is detected. In this way, an optical communication network with high reliability, safety, flexibility and strong disaster resistance is established.
Overview
Specifications
| Parameter | Value |
|---|---|
| Working wave length range | 1260 nm ~ 1650 nm |
| OLP Type | OLP-1:1 |
| OLP Type | OLP-1+1 |
| OLP Type | OLP-1-1 |
| OLP Type | OLP-1-1-BIDI |
| Switching time @ OLP type: OLP-1:1 | <35 ms |
| Switching time @ OLP type: OLP-1+1 | <15 ms |
| Switching time @ OLP type: OLP-1-1 | <15 ms |
| Switching time @ OLP type: OLP-1-1-BIDI | <15 ms |
| Introduction loss(A pair)-Main path @ OLP type: OLP-1:1 | <4.5 dB |
| Introduction loss(A pair)-Main path @ OLP type: OLP-1+1 | <2.0 dB |
| Introduction loss(A pair)-Main path @ OLP type: OLP-1-1 | <2.0 dB |
| Introduction loss(A pair)-Main path @ OLP type: OLP-1-1-BIDI | <4.5 dB |
| Introduction loss(A pair)-Backup path @ OLP type: OLP-1:1 | <4.5 dB |
| Introduction loss(A pair)-Backup path @ OLP type: OLP-1+1 | <2.0 dB |
| Introduction loss(A pair)-Backup path @ OLP type: OLP-1-1 | <2.0 dB |
| Introduction loss(A pair)-Backup path @ OLP type: OLP-1-1-BIDI | <4.5 dB |
| Monitoring Power Range | -50 dBm ~+25 dBm |
| Working temperature range | -10 ℃~60 ℃ |
| Working humidity range | 5 %~95 % no condensation |
| Storage Temperature | -40 ℃~85 ℃ |
| Equipment dimension | OSP3800 1RU: 442(W)×350(D)×44(H)mm 7211 1RU:442 (W)×250 (D) ×44 (H)mm |
| Network Management | Support multi-kinds of graphical interface network management, such as SNMP, Web |
| Optical Interface | LC/UPC |
| Power Supply | AC: 90 ~ 260 V or DC: -72~ -36 V (support 1+1 power input backup) |
| Typical power consumption | Full configuration <30 W |
| Heat dissipation | Fan cooling |
| MTBF | >100000 hours |
Datasheet
Please provide your email to download the datasheet.
Invalid email format. Please try again.
Supplier Information
Loading...
Name
Phone
Organization
Use Case

Database Platform